    Bacnet Stat w/dehumidification

    Does anyone know of a Bacnet programmable fan coil thermostat like the Honeywell TB series that will do dehumidification with a modulating reheat? It looks like the Viconics/Honeywell/JCI/etc brand...
  2. Replies
    1
    Views
    198

    Trane BCI-C RTAC Chiller Setup

    I'm trying to set up a RTAC chiller with a BCI-C bacnet controller. I've setup the baud rate and address on the controller. Following the integration instructions, using Techview I tried to enable...
  3. Replies
    0
    Views
    187

    Multiple Fan Coils, 1 Thermostat

    Has anyone tried connecting 2 modulating chilled water fan coil units to a single Honeywell TB7300 Series thermostat? Both units would run in tandem whenever there is demand.

    Thanks
  4. Replies
    1
    Views
    275

    Honeywell Spyder & 4-20ma Inputs

    Do the Honeywell Spyder controllers accept 4-20ma Inputs? Besides replacing the sensors with 0-10v sensors, is there any other work around for a 4-20ma sensor?
  5. Replies
    15
    Views
    2,026

    I know this is an old thread but I had the same...

    I know this is an old thread but I had the same questions and it help me find some answers. It looks like the connector is now available from Mitsubishi as part no. PAC-715AD. Here's a link to the...
  6. Replies
    6
    Views
    651

    Flow meter/switch

    Does anyone know of a flow meter that has both analog and binary outputs. I am trying to remove a flow switch that is being used for a chiller and replace it with something that can act as a switch...
  7. Replies
    0
    Views
    716

    Austin Controls Job

    Looks like the Texas Facilities Commission is hiring a controls guy if anyone is interested. Here is the link to their posting on the work in texas website.
    ...
  8. Replies
    4
    Views
    906

    I just reviewed the programs in CCT and found a...

    I just reviewed the programs in CCT and found a Zone Netsensor that was in the originally program but the inputs were hardwired instead. Deleted the "occupied mode" output point and it was removed...
  9. Replies
    4
    Views
    906

    Thanks for the replies...I looked at it today and...

    Thanks for the replies...I looked at it today and the light is actually flashing. I'm looking into your suggestions. Let me know if you have any other ideas.

    Thanks
  10. Replies
    4
    Views
    906

    JCI FEC Fault Light

    I have an Johnson Controls FEC 1610 that has a fault light on. The programming and boot versions were updated about 6 months ago. It is communicating and operating correctly. What does this fault...
  11. Replies
    4
    Views
    834

    Weather Station

    Does anyone have any recommendations for a high quality weather station to measure outside air temperature and humidity? I would like it to be compatible with either a Siemens or JCI controls system.
  12. Replies
    7
    Views
    753

    UPS with external contacts

    Does anyone know of a small UPS that has external contacts for battery level/alarms? I have some UPSs on my controllers that are in remote locations where no one hears the audible alarm and would...
  13. Replies
    8
    Views
    728

    The points are on a DCM and are PID loops. ...

    The points are on a DCM and are PID loops. Whenever they were programmed, they did not use a separate variable for the setpoints so to adjust them you must command the PID setpoint. I have tried...
  14. Replies
    8
    Views
    728

    This is on version 3.0. When I try to add the...

    This is on version 3.0. When I try to add the points to the NC, they don't show up in the list of points discovered but when I look at the engineering tab for the integration they are listed and...
  15. Replies
    8
    Views
    728

    PMI Point Migration

    I have a bunch of points that were migrated to JCI Metasys from PMI but I noticed some of the setpoints that are used for PID loops are not available in the points list in Metasys. Is there a way to...
  16. Replies
    6
    Views
    815

    Go to the system activity log. On the top menu,...

    Go to the system activity log. On the top menu, select query. You can select your options there. Limit it to certain points, users, and select the date range.
  17. Replies
    13
    Views
    1,185

    Sounds like this is the way to go for me. Thanks...

    Sounds like this is the way to go for me. Thanks for all the help and information.
  18. Replies
    6
    Views
    1,073

    So would the FX 60 be a direct replacement for...

    So would the FX 60 be a direct replacement for the NAEs? What about an NIE? There are still 2 buildings with old PMI controls. JCI hasn't really mentioned putting a FX60 as a replacement but it...
  19. Replies
    13
    Views
    1,185

    So instead of buying a PXC with bacnet...

    So instead of buying a PXC with bacnet capabilities I would have them buy the single site bacnet license for insight and set up a new bacnet bln. If I went with bacnet IP instead of MSTP then I...
  20. Replies
    6
    Views
    1,073

    Metasys Update

    I have a site that is running Metasys version 3.01 that is looking to complete an upgrade. They were told by JCI that some of the NAE's were not compatible with upgrading the system to 4.x or above....
  21. Replies
    13
    Views
    1,185

    It is for an Apogee system with a PXC Modular...

    It is for an Apogee system with a PXC Modular controller with P2 and BACnet. These tools are required to build the application and add it to system profile to view the points. The application has...
  22. Replies
    4
    Views
    705

    I think the fact you have exposure to controls...

    I think the fact you have exposure to controls and even have taken courses will definitely help you. I often see control companies hire people with no actual controls experience at all and some of...
  23. Replies
    13
    Views
    1,185

    Siemens Integration

    I'm working on a BACnet chiller integration into a Siemens control system and am needing the application builder and firmware loading tool to get my points in the BAS. Anyone out there have a copy...
  24. Replies
    16
    Views
    1,447

    Have you tried making a new program in CCT custom...

    Have you tried making a new program in CCT custom to your system?
  25. Replies
    16
    Views
    1,447

    What version of CCT do you have? Applications...

    What version of CCT do you have? Applications built in newer versions are not compatible with older versions.
  26. Replies
    16
    Views
    1,447

    What type of controller is it for?

    What type of controller is it for?
  27. Replies
    2
    Views
    1,063

    Siemens Bacnet FLN

    I am thinking about adding a new Siemens PXC Modular with Bacnet FLN to an existing system to integrate with a chiller and was wondering about building the application. Can I import the application...
  28. Thread: MCS-Config

    by zeppelin913
    Replies
    9
    Views
    1,183

    Ok, should be there now. Thanks

    Ok, should be there now.

    Thanks
  29. Thread: MCS-Config

    by zeppelin913
    Replies
    9
    Views
    1,183

    I appreciate it. Thanks!

    I appreciate it.

    Thanks!
  30. Thread: MCS-Config

    by zeppelin913
    Replies
    9
    Views
    1,183

    Yes, that is what I'm talking about except you...

    Yes, that is what I'm talking about except you need a password to download the file.
  31. Thread: MCS-Config

    by zeppelin913
    Replies
    9
    Views
    1,183

    MCS-Config

    Does anyone out there have a copy of MCS-Config. I'm having trouble getting some modbus communications to work and want to look over the config file.

    Thanks
  32. Replies
    25
    Views
    3,236

    I was able to do the upload using SCT to restore...

    I was able to do the upload using SCT to restore my database in the NAE. Once I was successful with that I didn't want to screw things up by using the NUT. It's still online and working so far. I...
  33. Replies
    25
    Views
    3,236

    Well, my NAE is talking to metasys now. I pulled...

    Well, my NAE is talking to metasys now. I pulled it from the network and was still unable to make any progress. I tried putting another network card on the PCI slot inside and this made a big...
  34. Replies
    25
    Views
    3,236

    I think I might be getting to the root of the...

    I think I might be getting to the root of the problem. I remoted into this NAE and another one on the same switch and found a big difference in file transfer time over the network. I copied the...
  35. Replies
    25
    Views
    3,236

    BTW, I am going directly from the server here...

    BTW, I am going directly from the server here through the switch to the NAE for the update.
  36. Replies
    25
    Views
    3,236

    Here is the log when doing the update. ...

    Here is the log when doing the update.


    27/01/2012 08:43:41.632 The DHCP client IP address space is: 192.168.127.1/255.255.255.0 - Total addresses = 254
    27/01/2012 08:43:41.647 Current...
  37. Replies
    25
    Views
    3,236

    I was able to remote into the NAE and get into...

    I was able to remote into the NAE and get into the windows explorer. Just let me know what to do next. I appreciate the help on this.
  38. Replies
    25
    Views
    3,236

    I tried the dump and got all the info that I had...

    I tried the dump and got all the info that I had already. SCT will not connect to the device giving a communication Error (521). I also already tried the reset button in the panel and it didn't...
  39. Replies
    25
    Views
    3,236

    I got the ip address from NAEIPTracker and tried...

    I got the ip address from NAEIPTracker and tried to connect to it and the Java Web Start page takes about 30-40 minutes to load. When it comes up I none of the passwords work. Just pops up with...
  40. Replies
    25
    Views
    3,236

    The version of SCT is 3.0. As far as the NAE, I...

    The version of SCT is 3.0. As far as the NAE, I am unable to log into it. It will not accept any passwords. It is supposed to be a static IP address but looks like its some how ended up DHCP. I...
  41. Replies
    25
    Views
    3,236

    It is an NAE5501-0. I am only able to get into...

    It is an NAE5501-0. I am only able to get into the log-in screen when I try to log into it thru a switch. It will not accept the metasyssysagent or basicagent users saying the password is invalid. ...
  42. Replies
    25
    Views
    3,236

    NAE55 Factory Reset

    I am having trouble with one of my NAE55s. It was losing connection and then completely dropped from my network. One of my employees disconnected power and the battery and it restarted. The IP...
  43. Replies
    3
    Views
    428

    That is probably the problem then. I didn't...

    That is probably the problem then. I didn't change the instance number. How do I know what to set it to? Thanks
  44. Replies
    3
    Views
    428

    JCI FEC not communicating

    I'm having trouble getting a new FEC to communicate with an existing Metasys system. I loaded the FEC with CCT find and it is working stand alone but I can't get Metasys to talk to it. When I used...