  1. Thread: nozzle size

    by seraaco
    Replies
    2
    Views
    317

    nozzle size

    Hi all

    Does anyone here have the drill size for each nozzle ring? i have the OD diameters but I'm looking for the orifice size.

    I need to replace a G6 with a G12 and a G8 with a G15 due to...
  2. Replies
    12
    Views
    971

    BDOLIN do you have any information about...

    BDOLIN do you have any information about proactive defrosts? I am interested in that
    thanks
  3. Replies
    3
    Views
    782

    Here is an article about this topic

    Here is an article about this topic
  4. Replies
    3
    Views
    782

    hsk7461-80 bitzer compressors on a medium temp...

    hsk7461-80 bitzer compressors on a medium temp rack using 404A
  5. Replies
    3
    Views
    782

    superheat using 404 screw comp?

    What is the lowest suction superheat allowed when using screw compressors on a med temp rack?

    I read 4 to 10 is normal due to efficiency.

    Thanks
  6. Replies
    7
    Views
    778

    If it's wired in parallel with the compressor it...

    If it's wired in parallel with the compressor it will, if wired to a board or diferent circuit it could cycle.
  7. Replies
    0
    Views
    380

    HSK7461-80 BITZER SCREW

    Hi fellas

    does anyone have a pdf incluiding the economizer operation on this compressor ? thanks a lot
  8. Replies
    9
    Views
    1,185

    The reason for a temp bulb installed in the air...

    The reason for a temp bulb installed in the air discharge is to prevent iced up coils when a lot of air infiltration is present such as open cases, prep rooms and heavy traffic w/i boxes.
  9. Replies
    49
    Views
    3,010

    Split the system n put nitro on every section, if...

    Split the system n put nitro on every section, if the leak is not too obvious leave all sections with nitro and comeback in the morning
    you'll see which one has lost pressure and can start looking...
  10. Thread: R 507

    by seraaco
    Replies
    24
    Views
    2,195

    R507 is : HFC-125 50% wt ...

    R507 is : HFC-125 50% wt
    HFC-143a 50% wt
    azeotropic blend


    R404A is: HFC-125 44% wt
    HFC-143a 52% wt
    HFC-134a 4% wt
    zeotropic...
  11. Thread: R 507

    by seraaco
    Replies
    24
    Views
    2,195

    like JP said interesting info but of course if...

    like JP said interesting info but of course if someone wraps a whole teflon tape roll around a fitting could be possible that the nut will expand
    also i have never seen a perfect threaded...
  12. Thread: R 507

    by seraaco
    Replies
    24
    Views
    2,195

    doctor that's what i know up to now teflon is a...

    doctor that's what i know up to now
    teflon is a refrigerant friendly material
    that information will be helpfull
    thanks a lot
  13. Thread: R 507

    by seraaco
    Replies
    24
    Views
    2,195

    great reply guys thanks a lot but still the same...

    great reply guys thanks a lot but still the same i haven't found any information about R507 being not teflon friendly
  14. Thread: R 507

    by seraaco
    Replies
    24
    Views
    2,195

    it's a new store new equipment so i know that...

    it's a new store
    new equipment
    so i know that some materials will react to poe oil but i'm talking about new equipment
    i haven't heard before that R-507 will shrink or degrade teflon tape...
  15. Thread: R 507

    by seraaco
    Replies
    24
    Views
    2,195

    R 507

    have anyone heard about this????
    I was just told that R507 is a solvent and will destroy teflon tape, so leaks will show up; it's a new store n after a month from start up a small leak found.
    I ask...
  16. Are you talking about hot gas defrost systems????

    Are you talking about hot gas defrost systems????
  17. Replies
    13
    Views
    962

    turn it off that way you'll reach that suction...

    turn it off that way you'll reach that suction pression LOL
  18. Replies
    9
    Views
    1,175

    i hear you sometimes they are just reading what...

    i hear you
    sometimes they are just reading what you are listening
    so it's our job to figure it out
  19. Replies
    9
    Views
    1,175

    when the supco guy said to switch the wires, i...

    when the supco guy said to switch the wires, i think i ment at the main power supply., that way you will have power at common terminal all the time
  20. Thread: E2 problem

    by seraaco
    Replies
    14
    Views
    1,074

    yes it has a bad input it keeps reading a...

    yes it has a bad input
    it keeps reading a sensor even when nothing is connected to the piont on one board, the connector removed n still reading a temperature, i will try to unplug the bad board n...
  21. Thread: E2 problem

    by seraaco
    Replies
    14
    Views
    1,074

    we already clear and reset the controler and...

    we already clear and reset the controler and reload the program again but still doing the same sh.t
    it looks like a bad controller to me
    thanks
  22. Thread: E2 problem

    by seraaco
    Replies
    14
    Views
    1,074

    we called them today and download a new firmware...

    we called them today and download a new firmware but this problem persists
    all wiring is ok everything works fine untill you want to change a setpoint
    and yes this is E2 but not an einstein is a...
  23. Thread: E2 problem

    by seraaco
    Replies
    14
    Views
    1,074

    E2 problem

    Hi all
    if i try to change anything on any system, the controler will loose all inputs n output settings for that system
    if i just want to change the temp or a defrost i can't even read the...
  24. Replies
    5
    Views
    523

    is the condenser clean? cond fan run n blades...

    is the condenser clean?
    cond fan run n blades ok?
    subcooling?
    txv ok?
    superheat?
  25. Replies
    5
    Views
    593

    water acts as a mirror and reflects the sun to...

    water acts as a mirror and reflects the sun to the building adding an extra heat load
    same thing happenned in Puerto Vallarta they didnīt add this load when estimating loads and equipment was too...
Results 1 to 25 of 87