  1. ASHRAE 62 is the design standard for systems....

    ASHRAE 62 is the design standard for systems. Buildings don’t need to be operated to the standard. There are many uncontrolled variables, people move around, some areas stink, under sized heating...
  2. Replies
    1
    Views
    202

    Update; I integrated the schedules into the Jace...

    Update; I integrated the schedules into the Jace and it works well. much better group commanding,.
  3. Replies
    1
    Views
    202

    Metasys Batch commanding schedules

    It sure would be nice to be able to batch command schedules in Metasys. Say, select all schedules then right click to, adjust start time...
    Can I suck the JCI Schedules into a JACE and modify them...
  4. Replies
    20
    Views
    2,752

    Hey Sinux. I did a large number of controls...

    Hey Sinux. I did a large number of controls projects with a great team in AK in the 90's/2000 I remember the majority of buildings having Honeywell fire or controls. My point is that this does not...
  5. AAON uses a Field Server card

    The AAON uses a field server card to translate the Wattmaster controls to BACnet MSTP. You can upload the “table” in the Field Server and edit the file, I think its a CSV file. It’s kind of a lot to...
  6. Replies
    13
    Views
    1,613

    Jeremy Thanks for taking the time to respond....

    Jeremy
    Thanks for taking the time to respond. I'm concerned because I have a many sites that have NAE's and all the MS/TP trunks are set to 2000 it's all being monitored from a Richard-zeta UI via...
  7. Replies
    13
    Views
    1,613

    I’m not sure I understand. Why would you need to...

    I’m not sure I understand. Why would you need to change the field bus number?
    Each NAE/NCE has a unique number correct? NAE1=500, NCE2=501, NCE2=502,
    Wouldn’t the field bus number be a subset of...
  8. Replies
    3
    Views
    1,125

    Danfoss Turbocor Modbus Registers

    Does anyone have any information about Danfoss Turbocor Modbus Registers, register map, type, or data format?
  9. Thread: SNMP?

    by CascadeControl
    Replies
    8
    Views
    1,219

    The new trend in data centers is high-density...

    The new trend in data centers is high-density racks. Typically they have something other than forcing cold air up from the floor. They have some kind of built-in cooling system. Redundant mechanical...
  10. Thread: SNMP?

    by CascadeControl
    Replies
    8
    Views
    1,219

    SNMP?

    Integrating servers to building mechanical systems is important. What about integrating security systems to lighting controls to shutdown the lights when the space is unoccupied or shutting down...
  11. Replies
    5
    Views
    936

    Sorry, Time to upgrade. They have a batery in...

    Sorry, Time to upgrade.

    They have a batery in them that fails overtime. Once the batery fails you have to reload them and replace the batery. This costs more then an upgrade.
  12. Replies
    3
    Views
    511

    Circon NV Description

    Is there a standard point description for a Circon UHC-202? When I upload the XIF file I don't get the point names.

    Any help would be appreciated.
  13. Replies
    5
    Views
    1,411

    Never mind it works fine.

    Never mind it works fine.
  14. Replies
    5
    Views
    1,411

    Metasys and Windows 7 XP Mode

    Has anyone had any luck installing the Johnson Controls SCT/CCT on a Windows 7 Machine in XP Mode?

    BTW… It works in a VDI on 2008 Server.
  15. Try Right clicking on the NAE/NIE’s and command...

    Try Right clicking on the NAE/NIE’s and command them to archive.
    I find I have to do this a lot especially when dealing with LON stuff and discovering devices and points.
  16. Replies
    4
    Views
    710

    I think Crab Master is on to something. If you...

    I think Crab Master is on to something. If you have multiple services running try stopping all of them except one that the ADX is using. (MSSQLSERVER)
  17. Wireless pulse transmitter and receiver

    I need to monitor a gas meter that is outside the building. Does anyone know of a good wireless transmitter that will capture pulses from a gas meter and transmit to the DDC inside?
    I think BAPI...
  18. Replies
    4
    Views
    1,136

    Thanks.

    Thanks a ton!!
    It is the eclipse bypass that is giving me so much frustration. I'll try your recommendation tomorrow.
  19. Replies
    4
    Views
    1,136

    BACnet MS/TP a ABB Drive

    Was anyone had any luck integrating an ABB Drive on to a BACnet MS/TP with a JCI NAE.
  20. Staefa 2 PC Tool 9 Pin Cable "PIN OUT"

    Does any have the "PIN OUT" for the cable that gos from 9 pin to RJ11 on the card?

    Thanks
  21. Carrier 30RAN022-S-5110 Chiller Isolation

    Does anyone know if this chiller has internal isolation valves or a pump on the chilled water side? Model # 30RAN022-S-5110
    For some reason when I start the chiller the water flow jumps up
  22. Replies
    18
    Views
    1,652

    I have a customer with the same problem. I have...

    I have a customer with the same problem. I have tried repeaters, the micro caps with no luck. They still go offline for a second about once or twice a day. I ended up doing a lot of JC basic to mask...
  23. Replies
    19
    Views
    5,898

    Did you build a LON network? You should be able...

    Did you build a LON network? You should be able to see both devices online thru your LON interface.
  24. Number one customer

    Both stocks are way down.
    Looks like no end of the year bonus for them.
  25. Replies
    1
    Views
    483

    NAE BacNet ID's Safety Tip

    Safety Tip.
    If you change naming in SCT and download a NAE it scrambles the BacNet ID's
    Causing the 3rd party integration to have to rebind their points.
  26. Replies
    7
    Views
    2,046

    The damper motor has nothing to do with the AO's...

    The damper motor has nothing to do with the AO's

    If you want the motor to drive, command the smo to -100. or some negitive number.
  27. Replies
    21
    Views
    2,082

    Get connected

    Put the NAE on the internet. Then anyone with Ver. 2.2. could upload it (or download it) and send you a back-up. All you need is a static IP address on the internet. They cost about 40$ / month. ...
  28. Replies
    10
    Views
    2,297

    BACnet Graphics Packages

    I like the Johnson Controls NAE, but find the WEB 2.0 graphics kind of weak. It can be tricky to create a SVG file.
    Most of my customers don't know the difference between having software on a...
  29. Replies
    8
    Views
    1,606

    SVGz Graphics

    Is Adobe cs better at creating svg graphics for a NAE then Visio?
  30. Carbon Dioxide (CO2) demand controlled ventilation

    Do you guys have any thoughts about Carbon Dioxide (CO2) demand controlled ventilation? Are you seeing it commonly used? They seem to be the trend in movie theaters and schools, but what about...
  31. Replies
    9
    Views
    1,208

    2 big towers 6 cells each. Four of the 12 cells...

    2 big towers 6 cells each.
    Four of the 12 cells have VFD's
  32. Replies
    9
    Views
    1,208

    Thanks

    I just completed a controls upgrade of a large central plant and I changed the sequence from dedicated towers to running the towers together. I appreciate all our comment and will use them going into...
  33. Replies
    9
    Views
    1,208

    Cooling Tower Isolation

    Is there any good reason to isolate a cooling tower, other then for service?
    It seems more efficient to let the water flow over them.
    Is there a minimum water flow I should be concerned about?
  34. Replies
    4
    Views
    705

    Some phones are funny how they receive e-mails....

    Some phones are funny how they receive e-mails. You may have to send the e-mails to a gmail account to view it on your phone.

    Are you able to view the NAE alarm e-mails on your “personal email...
  35. Replies
    3
    Views
    984

    found problem Microsoft Security Bulletin...

    found problem

    Microsoft Security Bulletin MS05-026 update on your computer.
  36. Replies
    3
    Views
    984

    JCI NAE Help Menu

    How do I get the NAE Help Menu to work?

    I get a "The page cannot be displayed" error.
  37. Replies
    3
    Views
    1,302

    Yes, You connect to the NAE with a null modem...

    Yes, You connect to the NAE with a null modem cable restart the NAE it will give you the currect IP. I have never done this, but I have seen it done.

    It may be easer to just guess. DHCP or Static?...
  38. Replies
    1
    Views
    703

    NAE with Iconics? or M-Graphics?

    Has anyone out there used an Iconics graphic package with a NAE? Or how about any other third party “PC based” graphics software?
  39. Replies
    70
    Views
    6,619

    Outsourcing

    Outsourcing is he future of all new construction. I have done a couple of jobs for mechanical contractors w/ factory-supplied controls on EVERYTHING. All I do is ad a COM trunk and intergrade to it...
  40. Replies
    5
    Views
    1,656

    Yes, It is a JCI Custom application for HVACpro....

    Yes, It is a JCI Custom application for HVACpro. JCI developed it for Hines Property management. It is used a lot in Seattle because it is in the Seattle mechanical code to very the speed of the...
  41. Replies
    6
    Views
    831

    BacNET IP a Trane Unit

    I have a job with a large Trane Rooftop Unit. I would like to BacNET IP into the unit. The local Trane guy says that he ONLY can do a LON Card. This would cost me more $. Does Trane have a BacNET...
  42. Replies
    17
    Views
    1,675

    I easiest way to get a database backup is to put...

    I easiest way to get a database backup is to put the NAE on the Internet and have someone upload it and then e-mail it to you.

    SCT can be tricky to load and more tricky to switch revisions.