Search:

Type: Posts; User: dexman

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    755

    I have reset them by disconnecting R.

    I have reset them by disconnecting R.
  2. Replies
    19
    Views
    1,755

    Dont have the numbers handy robo but most all...

    Dont have the numbers handy robo but most all Goodmans round here have them. I can see from the posts that there is no definitive answer. Seems some do and some dont. I was hoping maybe all do or all...
  3. Replies
    19
    Views
    1,755

    Can't pump it down. Switch is on outdoor unit.

    Can't pump it down. Switch is on outdoor unit.
  4. Replies
    19
    Views
    1,755

    IN my six years of service experience, I have...

    IN my six years of service experience, I have never had to change a low pressure cutout switch on a heat pump. Do you have to evacuate to do this or does it have some type of valve under it. I'm...
  5. Replies
    18
    Views
    1,848

    you dont say.!

    you dont say.!
  6. Thread: lennox gas pack

    by dexman
    Replies
    2
    Views
    872

    rollout or flame sensor?

    rollout or flame sensor?
  7. Replies
    18
    Views
    1,848

    Thanks for the number curry. Lots of help. Turns...

    Thanks for the number curry. Lots of help. Turns out the igniter I put on would have worked but someone before me retro-replaced the board with one that does not step the voltage down to 120 for the...
  8. Replies
    13
    Views
    1,991

    Wont likely get 21 years out of American...

    Wont likely get 21 years out of American Standard. Better get another RHEEM!!!
  9. Replies
    10
    Views
    1,485

    Just kidding, he he he

    Just kidding, he he he
  10. Replies
    10
    Views
    1,485

    sounds normal for a lennox to me.

    sounds normal for a lennox to me.
  11. Replies
    18
    Views
    1,848

    Understood, and thanks. I dont make stuff like...

    Understood, and thanks. I dont make stuff like this a habit, but I find it hard to believe that everyone who has been in this business for years has not tried temporary fixes to get someone by till...
  12. Replies
    18
    Views
    1,848

    BTW curry, these two mounted the exact same, the...

    BTW curry, these two mounted the exact same, the retro was 1/4" shorter but still long enough to ignite gas.
  13. Replies
    18
    Views
    1,848

    I agree but I seriously doubt she has the money.

    I agree but I seriously doubt she has the money.
  14. Replies
    18
    Views
    1,848

    So what do you do when you have no model, serial,...

    So what do you do when you have no model, serial, or part numbers. You call your distributor and they're no help. And whoever was there before you cut the plug off and wirenutted a different igniter...
  15. Replies
    18
    Views
    1,848

    Retrofitted several as long as you get them...

    Retrofitted several as long as you get them mounted securely and in the right place they work just fine. Sometimes when your under the gun and people dont have heat, and the parts store is closed,...
  16. Replies
    18
    Views
    1,848

    I can tell you that it has an odd service door on...

    I can tell you that it has an odd service door on the right side of the unit. It goes together with the corner of the unit using two 45 degree angles.
  17. Replies
    18
    Views
    1,848

    ??? just a nordyne gas pack. Thats all I got...

    ??? just a nordyne gas pack. Thats all I got except a model number off a parts list i found in bottom of unit. it is R2GA.
  18. Replies
    18
    Views
    1,848

    Tech. First nordyne.

    Tech. First nordyne.
  19. Replies
    18
    Views
    1,848

    I just installed a hot surface igniter on a...

    I just installed a hot surface igniter on a nordyne unit. I couldnt find the exact one and all the numbers are washed off. so I retrofitted one that was close to that one. When I started the unit,...
  20. Replies
    15
    Views
    1,222

    Wasnt thanking you Dave, you dont seem to be...

    Wasnt thanking you Dave, you dont seem to be smart enough to be of any help. Guys like you, who dont know how to do anything usually say stupid things. BTW "It is better to sit quietly and be thought...
  21. Replies
    15
    Views
    1,222

    Thanks!!!

    Thanks!!!
  22. Replies
    33
    Views
    1,894

    Go out in the woods and practice for about 20...

    Go out in the woods and practice for about 20 years before you try it. I know professional loggers who have had trees fall the wrong way and damage property as well as hury other people. I have cut...
  23. Replies
    15
    Views
    1,222

    No garbage disposal. Its just in bathroom sinks....

    No garbage disposal. Its just in bathroom sinks. only smells when water is running. Also on windy days, you can smell the vent gases outside. Is that normal? This is my first house with a 4"...
  24. Replies
    15
    Views
    1,222

    Just wondering what causes drains to smell like...

    Just wondering what causes drains to smell like sewage. Thought it was the water but after putting some clorox in the traps, oder is gone. Trouble is, it comes back in a few weeks. This is a new...
  25. Replies
    70
    Views
    4,518

    Funny thing around here is that after all this...

    Funny thing around here is that after all this trouble and work and fine tuning, the customer will probably never get it serviced and eventually dirty blower wheels and coils will change everything...