  1. Replies
    21
    Views
    3,838

    I put in safety shut off on aux drain hole and...

    I put in safety shut off on aux drain hole and see no reason for aux. pan in dirt basement do you?
  2. Replies
    21
    Views
    3,838

    ok so it has 2 marks lets say you want 6' of pipe...

    ok so it has 2 marks lets say you want 6' of pipe to be on the left side of benders so you put that measurement on the mark on the left side of the benders?
  3. Replies
    21
    Views
    3,838

    OK I have a question about the tubing benders. I...

    OK I have a question about the tubing benders. I do not do many installs so when I do break out the benders I have yet to figure out the measuring to get my ben in the right place. On 3/4 I believe...
  4. so where is the picture of your unit?

    so where is the picture of your unit?
  5. Replies
    13
    Views
    504

    did you read this? A vent termination shall...

    did you read this?

    A vent termination shall not terminate over public walkways
    or over an area where condensate or vapor could create
    a nuisance or hazard or could be detrimental to the...
  6. Replies
    26
    Views
    1,495

    In the south yea summers are going to be busy...

    In the south yea summers are going to be busy very very busy but we expect that and that is when most of our money is made. So do not spend it as winter will not pay as much. While in atlanta the...
  7. ok lets think this out you are going to go to an...

    ok lets think this out you are going to go to an interview and tell your prospective boss that you do side jobs? how do you think he will take this? I would think that at nights or weekends you...
  8. as stated it is normal. when you change the...

    as stated it is normal. when you change the temperature it will come on like that however if you set it and leave it the aux. heat will not come on as often.
  9. Replies
    23
    Views
    911

    The AS was a package unit, and the other unit was...

    The AS was a package unit, and the other unit was a split heat pump but no humidifier was on it either. the clear p-trap on the split was full of what looked like sheet rock dust. However there had...
  10. Replies
    23
    Views
    911

    it is in the airflow. The AS drain pan I...

    it is in the airflow. The AS drain pan I replaced the problem was cured. You tell me how if it was not the drain pan.
  11. Also as mentioned earlier a pm/maintenance would...

    Also as mentioned earlier a pm/maintenance would have been good to do as they would have found all issue's with both units and been able to correct them for you. maintenance for your heating and...
  12. above post is probably right

    above post is probably right
  13. Replies
    8
    Views
    268

    Here is a copy of Nordyne's quality pledge. This...

    Here is a copy of Nordyne's quality pledge. This says Broan but it should be the same for all of nordyne.

    535751
  14. Replies
    8
    Views
    268

    No labor warranty for that. the part is free but...

    No labor warranty for that. the part is free but you pay all labor. Unless you purchased or were sold an extended labor warranty.
  15. Replies
    8
    Views
    268

    I do not understand just serviced to me means...

    I do not understand just serviced to me means someone just checked and cleaned the unit. the only time nordyne pays $250 is when the compressor or heat exchanger fails with in 10 years and then the...
  16. Replies
    39
    Views
    1,474

    went to start up some furnaces on a new...

    went to start up some furnaces on a new residential construction and the d/s furnace would not make the pressure switch so I pulled the flue off and found that someone had taken a dump and placed it...
  17. Replies
    34
    Views
    1,174

    thank you.

    thank you.
  18. Replies
    34
    Views
    1,174

    can nest work with dual fuel? With out an...

    can nest work with dual fuel? With out an outside temp i do not see it being too eff.
  19. Replies
    34
    Views
    1,139

    very good. Maybe think of it like this you are...

    very good. Maybe think of it like this you are checking voltage along the piece of wire in different spots. you will get voltage.
  20. Replies
    4
    Views
    264

    no way of re setting it, it is default to blow...

    no way of re setting it, it is default to blow the hot air down to the ground where it is colder. This is the number one reason not to put it over a bed.
  21. Replies
    13
    Views
    674

    Try this. ...

    Try this.

    http://www.robertshawtstats.com/spaw2/SiteContent/Files/FAQ/ControlTips-MillivoltSystems.pdf
  22. Replies
    34
    Views
    1,139

    Correct, that non energized leg is doing no work.

    Correct, that non energized leg is doing no work.
  23. wouldn't an hrv or erv be another option here?

    wouldn't an hrv or erv be another option here?
  24. Replies
    11
    Views
    305

    yes, get someone out that knows what they are...

    yes, get someone out that knows what they are doing.
  25. Replies
    10
    Views
    311

    The bigger picture is as stated earlier if you...

    The bigger picture is as stated earlier if you chimney does not have an internal line ran down/up it your chimney will fall apart. Really!

    Should be double wall from furnace to chimney. Single...
  26. Replies
    1
    Views
    156

    that should work.

    that should work.
  27. The only difference the 5 minute delay at the...

    The only difference the 5 minute delay at the t-stat will make is if unit is in delay and the t-stat is not then the fan will be running and blowing cold air in winter, warm or hot air in summer...
  28. Replies
    8
    Views
    247

    no problem some thermostats will raise or lower...

    no problem some thermostats will raise or lower the temperatures automatically but I believe programmable t-stats won't.
  29. Replies
    8
    Views
    247

    What is the cool set point set to? the reason I...

    What is the cool set point set to? the reason I am asking is some thermostats will not allow the heat to heat above the cool setting as then the ac will have to come on and cool the house down to...
  30. Replies
    8
    Views
    247

    what temp is the ac set to?

    what temp is the ac set to?
  31. here we go again we (hvac technicians) are all...

    here we go again we (hvac technicians) are all freaking thieves. PS this is not a DIY site.

    You might want to look at this thread:...
  32. my car won't start so I am going to kick the...

    my car won't start so I am going to kick the fenders and front bumper. Makes perfect sense.
  33. Replies
    23
    Views
    911

    I have seen one york split that produced white...

    I have seen one york split that produced white powdery looking substance was not sure hat it was but I think it was the drain pan. I seen an american standard package h/p do the same thing both were...
  34. Replies
    32
    Views
    2,676

    that is not even a coupling at that bottom elbow.

    that is not even a coupling at that bottom elbow.
  35. Replies
    14
    Views
    500

    I personally like a disconnect at the unit even...

    I personally like a disconnect at the unit even if there is a breaker in the unit and the breaker box is in sight. If I have the disconnect pulled the only way the unit can be powered up is if some...
  36. defrost will usually last at least 3 to 5 minutes...

    defrost will usually last at least 3 to 5 minutes maybe 15 the fan will be off the entire time it is in defrost. Can not tell what it is doing by estimating time a actual time should be kept of the...
  37. Replies
    9
    Views
    478

    In my opinion a hallway is not a bath room or...

    In my opinion a hallway is not a bath room or toilet room (at least not in my house).
  38. Replies
    3
    Views
    211

    are you looking under a/c or h/p?

    are you looking under a/c or h/p?
  39. Replies
    4
    Views
    294

    I would not put duct board in. I would use sheet...

    I would not put duct board in. I would use sheet metal for the main trunk and flex off of it.
  40. Replies
    2
    Views
    192

    as stated earlier t-stat does not bring on the...

    as stated earlier t-stat does not bring on the fan for the furnace you have an issue with furnace possibly.
  41. you can try consumer reports.

    you can try consumer reports.
  42. Replies
    9
    Views
    478

    I do not know about code but the reason you would...

    I do not know about code but the reason you would not want it there is due to odors. Weather they are pleasant or unpleasant they will be circulated all through the house.
  43. Replies
    25
    Views
    871

    if a company replaced it last year then the part...

    if a company replaced it last year then the part and labor could very well still be under warranty as most places I have worked have had a 1 year warranty on replacement parts and labor.
  44. Replies
    13
    Views
    674

    So you can get the outdoor coil to frost up in...

    So you can get the outdoor coil to frost up in 70+ degree temperatures to check the defrost stat and you can verify 100% in the winter that the refrigerant charge is spot on? If so you are a much...
  45. set it at a number that makes you comfortable. ...

    set it at a number that makes you comfortable. Do not worry if it is set at 72 and it is 71 in the house and you are cold set it to where you are comfortable and that is your comfort number.
  46. I have noticed on digital t-stats that they will...

    I have noticed on digital t-stats that they will give false information when there is much (>2 deg) temperature difference between room temp and set temp. It seems like the digital t-stat will show...
  47. does the furnace not have a diagnostic light that...

    does the furnace not have a diagnostic light that will flash a code when it fails and then someone could look at?
  48. Replies
    4
    Views
    337

    you can cap it in the winter but I would uncap it...

    you can cap it in the winter but I would uncap it in the summer. You can not prime it as the p-trap is up from the vent. In other words if you poured water into it it would run away from the p-trap...
  49. Replies
    4
    Views
    337

    it will dry out over the winter and you will no...

    it will dry out over the winter and you will no longer here it when it does. In the summer it will fill up and you will not here it then either.
  50. odors can be from installation they will...

    odors can be from installation they will dissipate with time usually 2 to 3 days they will be gone. It could be some type of glue or duct sealer. No welding of duct work was done, screws and tape...