  1. Replies
    24
    Views
    2,470

    There are two things you can be sure of in a...

    There are two things you can be sure of in a kitchen environment. Dirty, greasy, air cooled condensers with poor heat exchange properties and pourous, pitted evap coils caused by acids in many types...
  2. Replies
    10
    Views
    908

    the head pressure should never "skyrocket" , this...

    the head pressure should never "skyrocket" , this is probably caused by non - condensibles in the system. Remove refrigerant and pull a deep vacuum on system (below 500 microns and holds). This may...
  3. Replies
    6
    Views
    908

    Those settings seem fine. The old control may...

    Those settings seem fine. The old control may have been operating at the correct C-I and C-O. What a lp control indicates visually, and what it actually operates at, often conflict with each other.
  4. Replies
    16
    Views
    1,680

    the "throw stones" comment was not directed...

    the "throw stones" comment was not directed towards you , dave. Sorry for the misunderstanding. thanks for following up on the solution, selfemployed.
  5. Replies
    16
    Views
    1,680

    sorry for the sarcasm dave...but if you live in a...

    sorry for the sarcasm dave...but if you live in a glass house - you don't throw stones !
  6. Replies
    16
    Views
    1,680

    Hmmm... mechanically remove refrigerant, remove 6...

    Hmmm... mechanically remove refrigerant, remove 6 inches of cap tube, re-solder tube, pull deep vacuum on system, add nitrogen to verify leak-free and add refrigerant to system just to still have...
  7. Replies
    16
    Views
    1,680

    Remove refrigerant, replace filter drier and cap...

    Remove refrigerant, replace filter drier and cap tube (properly sized) Pull vacuum on system and slowly charge to about 13-17 PSI on suction. R134 systems are notorius for having restricted cap tubes...
  8. Replies
    7
    Views
    857

    Tecumseh puts out a free Service Handbook in PDF...

    Tecumseh puts out a free Service Handbook in PDF format, that has tons of great technical and reference material (including line sizing guides) It is a large file @ 3.7 MB , but well worth the wait....