Search:

Type: Posts; User: woodbury

Search: Search took 0.00 seconds.

  1. Replies
    40
    Views
    2,075

    Its not the size of the conduit that matters but...

    Its not the size of the conduit that matters but rather the conductor size
  2. Replies
    30
    Views
    2,216

    No tools - Call in sick - better for the company...

    No tools - Call in sick - better for the company than showing up unprepared.
  3. Replies
    36
    Views
    1,841

    When they set up the press to punch the knockouts...

    When they set up the press to punch the knockouts they go conservative for their own protection because if they set them too aggressive then they risk completely punching out a knockout which will...
  4. Replies
    16
    Views
    1,278

    If it does not light properly then the ignition...

    If it does not light properly then the ignition control will not sense flame then shut off so safe till you return
  5. Replies
    18
    Views
    858

    Very dangerous, I am sure this is written in the...

    Very dangerous, I am sure this is written in the installation manuel
  6. Replies
    52
    Views
    2,383

    If the voltage to the furnace dropped low enough...

    If the voltage to the furnace dropped low enough for the ignitor to only glow soft red then the inducer would not run at close to full speed which could be heard and it would drop out the pressure...
  7. Replies
    7
    Views
    752

    Make sure there is a trap on the drain tube as...

    Make sure there is a trap on the drain tube as there is negative pressure in the drain pan area which will prevent condensate from going down the drain.
  8. Replies
    246
    Views
    62,582

    Sticky: Poll: Goodman and Amana woodbury - You do not have...

    Goodman and Amana

    woodbury - You do not have permission to advertise your business. You must become a Pro Member first.

    Thank you,

    Mod Team
  9. Replies
    7
    Views
    4,285

    That is a nice clear answer BEENTHERE, thanks. ...

    That is a nice clear answer BEENTHERE, thanks. If only the would put that in the book.
  10. Replies
    7
    Views
    4,285

    Honeywell IAQ duel fuel settings

    What is the reason to use option 2 (Droop Control with Aux Heat lockout) when setting up duel fuel on IAQ. I usually have set them up with option 1

    Heat Pump Control ó Fossil Fuel Backup (Setup...
Results 1 to 10 of 10

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event