    and dont ever drop them. ever.

    and dont ever drop them. ever.
  2. Replies
    18
    Views
    615

    I feel like any penetrating oil that actually...

    I feel like any penetrating oil that actually works well is going to stink like that though...

    I carry Kroil in my truck and swear by it. Works well enough that you can use a TINY bit to do the...
  3. Replies
    15
    Views
    795

    The supply houses should all be able to get you...

    The supply houses should all be able to get you 502, but I doubt they keep it in stock these days. If I were buying some, I'd get it from ebay or some other place online as cheap as possible. A 30#...
  4. Replies
    33
    Views
    1,428

    You can also take your amp clamp (meter) and open...

    You can also take your amp clamp (meter) and open it, put the jaws around the coil so that one jaw is at the top and one is down near the bottom. Think like you're trying to get the jaws around the...
  5. Replies
    22
    Views
    691

    I've been around systems using HC refrigerants...

    I've been around systems using HC refrigerants off and on since I was brand new. It's really not tough to deal with. Run a hose outside, purge nitrogen, cut things out instead of unsweating...

    The...
  6. ^ No new installs with HCFC refrigerants due to...

    ^ No new installs with HCFC refrigerants due to the phase out... Maybe doesn't apply here?
  7. Worn contactors on 3-phase compressors can ground...

    Worn contactors on 3-phase compressors can ground them. (Single phase the motor and it's toast very quickly)

    Floodback can do it.

    Low side leaks on systems that run in a vacuum eventually do...
  8. Take any fan blade, flip it over, and the blade...

    Take any fan blade, flip it over, and the blade pitch is still in the same direction. It still flows air one way, only less efficiently in the case of a typical evap or condenser blade.

    A ceiling...
  9. It happens even with the big money biotech...

    It happens even with the big money biotech companies too.

    I recently spent 4+ months working on a freeze drier that had been sitting unused for TWO YEARS. It was sitting idle because the person...
  10. We cut one open at our shop after it restricted...

    We cut one open at our shop after it restricted completely. Total blockage. Found the desiccant encased in what looked like epoxy. We just figured that must be what happens when you put too much of...
  11. Replies
    133
    Views
    4,702

    Cincinnati Sub Zero makes test chambers with...

    Cincinnati Sub Zero makes test chambers with 410A. They have one with a compound compressor that will make -50C on 410A. It looks like a great low temp refrigerant when you're looking at the PT...
  12. Replies
    133
    Views
    4,702

    I've got a cascade process chiller with redundant...

    I've got a cascade process chiller with redundant compound Bitzer compressors for the low stage. -47F, also R507. Interstage suction cools a plate heat exchanger to subcool the liquid line before...
  13. Thread: r12 walk in

    by cmclifton
    Replies
    94
    Views
    2,085

    Coalescing oil separators, and just the simple...

    Coalescing oil separators, and just the simple fact that there's no oil left in the stream by the time you get past the last receiver and heat exchanger. The argon doesn't carry the oil the way the...
  14. Thread: r12 walk in

    by cmclifton
    Replies
    94
    Views
    2,085

    The overall COP... I haven't the slightest. I...

    The overall COP... I haven't the slightest. I wouldn't expect it to be good. 3 horse scroll to cool 5 cubic feet with something like 80% "on time". The rest... tbh I don't have the vocabulary to...
  15. Thread: r12 walk in

    by cmclifton
    Replies
    94
    Views
    2,085

    In the case of a Thermo -150 freezer, that argon...

    In the case of a Thermo -150 freezer, that argon does get somewhat condensed. It never becomes a full column of liquid, but it's not just there to keep pressures up. It's the argon that cools the...
  16. Thread: r12 walk in

    by cmclifton
    Replies
    94
    Views
    2,085

    I work on those things too. (-150 is a little...

    I work on those things too. (-150 is a little more common) You can't measure superheat and you know it.

    One of those refrigerants is argon. You're not ever going to get a Copeland engineer to be...
  17. Thread: r12 walk in

    by cmclifton
    Replies
    94
    Views
    2,085

    I know this is a waste of time, but I have to see...

    I know this is a waste of time, but I have to see this play out... What refrigerant is in that mythological piece of equipment that has 20 degrees superheat and 80 degree return gas?
  18. Thread: r12 walk in

    by cmclifton
    Replies
    94
    Views
    2,085

    Don't try too hard. There's very little logic...

    Don't try too hard. There's very little logic involved in checking subcooling on systems with receivers and ignoring superheat at the compressor ...And then calling the return gas temp measurement...
  19. Replies
    133
    Views
    4,702

    Me too :) the Wikipedia link was an afterthought....

    Me too :) the Wikipedia link was an afterthought. "Wait what if he's being serious?"
  20. Replies
    133
    Views
    4,702

    Subcooling is what fools people into thinking...

    Subcooling is what fools people into thinking they're fully charged when they've got a flashing sight glass and nitrogen in the top half of their condenser coil...
    ...
  21. Replies
    133
    Views
    4,702

    I'd hope so, but I've never seen a rack at full...

    I'd hope so, but I've never seen a rack at full capacity. I never got to do anything but service work on existing stores. I'd consider myself a complete failure if I let enough cases warm up to bring...
  22. Replies
    133
    Views
    4,702

    Now there's a good question. An R507 rack at...

    Now there's a good question.

    An R507 rack at ~30% capacity will definitely make you ponder that one. I think it's only there so you can look in there and imagine what it would feel like to be a...
  23. Replies
    133
    Views
    4,702

    Stop it. You're going to give someone a heart...

    Stop it. You're going to give someone a heart attack. :Faint:
  24. Replies
    133
    Views
    4,702

    What it does mean is that you don't get to...

    What it does mean is that you don't get to change what the subcooling is unless you have an active subcooling system (compound compressor or separate subcool system maybe). The fact that you have a...
  25. Replies
    133
    Views
    4,702

    "How am I going to get these guys to agree with...

    "How am I going to get these guys to agree with me that subcooling matters a lot on walk-in systems with receivers? I know, I'll make up a test scenario on something that is not at all like a walk-in...