    Nice Job. FYI Rheem wants 18 inches of straight...

    Nice Job. FYI Rheem wants 18 inches of straight pipe before any 90's on the exhaust vent in the install manual. It will work like you have it though.
  2. Are Rinnai and Jacuzzi Brand the same water heaters ?

    Ok Lowes sells Jacuzzi brand instananious water heaters.
    They sure look like Rinnai brand.
    Rinnai can only be bought from supply houses and i have taken the install classes.
    Why would they sell to...
  3. Ok i dont think a cat would crawl into flex and...

    Ok i dont think a cat would crawl into flex and piss and try to back out. But it sound like you should replace duct if they are filthy.
    I have been in many rental homes that have had carpets cleaned...
  4. Replies
    10
    Views
    874

    yes two pipe vented. Combustion from outside....

    yes two pipe vented. Combustion from outside. Well the undercut door will be around 3 inches. One supply and one return in attic would be a better air change.
  5. Replies
    20
    Views
    2,075

    The flame might not carry over everytime to the...

    The flame might not carry over everytime to the sensor. Clean or widen burner slot slightly.
  6. Replies
    10
    Views
    874

    Spray foamed attic and duct work question.

    1800's old House total remodel. Third floor attic is all new spray foamed roof, soffit , walls. NO ROOF VENTS at all now.
    Large staircase leading to this attic space. There will be a horizontal 95%...
  7. Replies
    14
    Views
    2,453

    Good question about the filters i never even...

    Good question about the filters i never even looked in the cabinet.
  8. Replies
    14
    Views
    2,453

    The original call was to install a toe kick...

    The original call was to install a toe kick supply in the new kitchen island, and get them new return grill sizes they cant find at the big box stores. Returns were the baseboard type.
  9. Replies
    14
    Views
    2,453

    Home owner duct run

    This furnace had 6 inch round returns everywere, even the back side of furnace.
    The supply plenum was the same.
  10. Replies
    7
    Views
    1,262

    Check each wire in mollex connectors individually...

    Check each wire in mollex connectors individually by pushing them into place.
    I had one a while back that had a loose flame sensor wire in the large connector harness.
  11. Replies
    12
    Views
    1,350

    Sold them a new R22 dry condenser. Running...

    Sold them a new R22 dry condenser. Running correct wire to new unit.
  12. Replies
    12
    Views
    1,350

    The name plate says 29 RLA compressor and 1.9...

    The name plate says 29 RLA compressor and 1.9 amps for fan.

    There is identical unit next to it with 8-2 and a 40 amp breaker.
    Must have been two electricians on same install years ago.

    Thanks...
  13. Replies
    12
    Views
    1,350

    update - Found unit not running. Tripped breaker....

    update - Found unit not running. Tripped breaker. Units duel capacitor was bad, tested with ohm meter herm side not good,plus shinny solder spot.
    Replaced with new 80/5 capacitor and a new hard...
  14. Replies
    12
    Views
    1,350

    Is this a 5 ton York ?

    Model - H4DE060S06A Condenser #
    Serial - WENM024695

    R-22 refrigerant - Scroll compressor.

    This unit has 10-2 wire and 30 amp breaker feeding it.
    Makes me question the tonage.
    Somebody...
  15. Replies
    99
    Views
    13,125

    Early 20's learning commercial work i set a small...

    Early 20's learning commercial work i set a small roof top on a curb with the crane company.
    Later that afternoon when the rest of my company showed up it was noted the supply and return were...
  16. Replies
    3
    Views
    387

    I took the test and failed by one question....

    I took the test and failed by one question. ASDFLKJ said it best. My company purchased the practice test online for us. Its a hard test and you cant use common sense. Its their fantacy world of rules...
  17. Replies
    1
    Views
    1,053

    Control smoker temp with old fan limit?

    Trying to modify my Brinkman Charcoal smoker. Want to put an air shutter on the dome that moves automatically when it gets too hot. Thinking of using an old fan limit with bimetal helix to twist open...
  18. Replies
    4
    Views
    552

    Customer had a question about Kerosene ..

    http://www.msue.msu.edu/objects/content_revision/download.cfm/revision_id.499650/workspace_id.-4/01500603.html/

    They wanted to heat their house with one of these.
    Told them not a good idea.......
  19. Replies
    9
    Views
    2,871

    Thank you that post had the answers i was looking...

    Thank you that post had the answers i was looking for.
  20. Replies
    9
    Views
    2,871

    Dry aged beef cooler?

    Do any of you have any info on setting up the humidity - temps for aging beef/venison correctly. I want to make a used reach-in cooler specifically for this.
    Personal use only.
  21. Replies
    16
    Views
    2,556

    They said it was that way for a year and it...

    They said it was that way for a year and it worked. I said it was wrong and explained why. They did not want it changed.
    What was i suposed to do turn off gas supply and tell them i cant leave it...
  22. Replies
    16
    Views
    2,556

    Ok its 26 guage at that point where cable went in...

    Ok its 26 guage at that point where cable went in but transitions to b vent
    at next fitting up chase to attic.

    I did mention it to home owners, they said their friend installed it for them to a...
  23. Replies
    16
    Views
    2,556

    Coax cable in b vent

    Saw this while installing ac for a newer home. They ran coax cable for the cable tv on the second floor in water heater b vent pipe. Poked another hole in vent in attic and fished it across ceiling...
  24. Replies
    12
    Views
    535

    NCI looks like good training. Have to get a class...

    NCI looks like good training. Have to get a class in Rochester NY started.
  25. Replies
    12
    Views
    535

    Why dont they put carbon monoxide sensors

    On new furnace models.
    They could be factory wired into they safety circuit to shut down furnace?
    The furnace may not be the source of the problem but that way the homeowner would have to placea ...
Results 1 to 25 of 130
Page 1 of 6 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event