  1. Replies
    33
    Views
    2,990

    Get a cost comparison done to see if the geo is...

    Get a cost comparison done to see if the geo is more cost effective for your area. Some air source are getting really good cop's but there is the defrost cost to add in depending on outdoor ambient...
  2. Ice machine descaler works and no glue on any...

    Ice machine descaler works and no glue on any fittings. All fused or barbed and clamped!
  3. Thats whats I use to clean coils (tankless pump)...

    Thats whats I use to clean coils (tankless pump) but somthing with a little more flow would be better IMO, and depending on water pipes (domestic or source) I will somtimes use just vinegar.
  4. Replies
    20
    Views
    2,868

    Gas fireplaces differ in their construction and...

    Gas fireplaces differ in their construction and operation. The newer styles with electronic ignition, power venting, and variable blowers do require maintenance or they typically stop working! As for...
  5. Replies
    6
    Views
    1,017

    Prepped joints!!! Whats that..... LOL. My guys...

    Prepped joints!!! Whats that..... LOL. My guys may wipe the joint off with a rag but I would think thats as far as they go. And yes I have showed, explained, and explained again but no one listens!!!!
  6. Replies
    10
    Views
    1,582

    Thx Eric. I dont think i need a flow meter unless...

    Thx Eric. I dont think i need a flow meter unless i'm missing something! I have the proper flow now. Would the pressures change in a nonpressurized loop?
  7. Be very careful with duct sizes as was said. My...

    Be very careful with duct sizes as was said. My biggest issue is just that, new unit was installed on air source system and ducting was to small, variable blower will not fix this and u may have...
  8. People that can't do, "teach", people that can't,...

    People that can't do, "teach", people that can't, "do or teach",.......... lie. lol
  9. Replies
    10
    Views
    1,582

    It is a freeze protected loop (propylene glycol)...

    It is a freeze protected loop (propylene glycol) which is what I use now due to the safety and toxic issues. Yes I know its not the best choice but for me it is the least toxic and safest mix. I am...
  10. Replies
    0
    Views
    844

    Leaky Loop!!!

    So I have a problem. After many years of repressurizing loops on a yearly basis from other installers I have one that we installed 2 years ago that is losing pressure.
    Every 6 months I recharge it...
  11. Replies
    10
    Views
    1,582

    Leaky Loop!!!

    So I have a problem. After many years of repressurizing loops on a yearly basis from other installers I have one that we installed 2 years ago that is losing pressure.
    Every 6 months I recharge it...
  12. Replies
    6
    Views
    1,017

    SF1 Brazing rod

    Company just ordered in some SF1 rod and I am not familiar with it. Has anyone used it and what are your thoughts?
  13. Replies
    33
    Views
    1,582

    Match the hatch LOL. If dont have proper size +...

    Match the hatch LOL. If dont have proper size + or - 10% will work but change to proper size soon and check both run and start amps. kinda hard on motor in my opinion to leave wrong one in system.
  14. Replies
    11
    Views
    1,070

    Superheat???? If you have a negative SH you...

    Superheat???? If you have a negative SH you probably have no orifice and your evap is now a condensor...... :-O. If your SH is low wrong size!
  15. Replies
    16
    Views
    767

    WOW lots of awnsers. IMO anything below 65f...

    WOW lots of awnsers. IMO anything below 65f outdoor amb. should have low ambient controls installed be it solidstate or mechanical. This would include cond. fan cycling controls and a freeze stat on...
  16. Replies
    4
    Views
    427

    restriction = high SH, higher than normal SC....

    restriction = high SH, higher than normal SC. also watch head when adding as it will rise rapidly with restriction.(IMO lol)
  17. Replies
    5
    Views
    662

    Jeez I been gone for awhile but things sure have...

    Jeez I been gone for awhile but things sure have gotten vague around here! 410 or 22? SH and SC? My crystal ball is getting a work out!!! LOL
  18. Replies
    17
    Views
    1,130

    Does lennox use a micro channel coil?

    Does lennox use a micro channel coil?
  19. Replies
    17
    Views
    1,130

    There is always a chance of shorting compressor...

    There is always a chance of shorting compressor (scroll) when pumping down although never has happened to me. I typically reclaim now in all situations just to know what charge is.
  20. Replies
    2
    Views
    341

    Yes it is! What is the issue with unit?

    Yes it is! What is the issue with unit?
  21. Replies
    18
    Views
    5,115

    If used as per instructions it does work. I will...

    If used as per instructions it does work. I will only use it on older systems that people do not want to replace. R-22 systems that I cannot locate leak after pressure testing. I have used it on 2...
  22. Replies
    17
    Views
    1,130

    What Dandy me said!!!

    What Dandy me said!!!
  23. Replies
    23
    Views
    1,280

    Sounds like your real close, we had some issues...

    Sounds like your real close, we had some issues with York overcharging using ADP coils to get ashrae numbers, most had to have charge removed (few ounces) on start up.
  24. Replies
    23
    Views
    1,280

    I have heard that 410 will some times have gas...

    I have heard that 410 will some times have gas bubbles showing even when properly charged so sightglass not always reliable. I will usaully pull and wieght charge to confirm and go from there. "When...
  25. Replies
    10
    Views
    526

    UV kills things eac burns thing lol

    UV kills things eac burns thing lol