Search:

Type: Posts; User: conspiracy_luvr

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    59
    Views
    6,373

    Dont be a fool reset your tool.

    Dont be a fool reset your tool.
  2. Replies
    59
    Views
    6,373

    I get them from flaretite.com and I don't have...

    I get them from flaretite.com and I don't have company stock, hehe. They work well with little clips on them to snap onto the male end, then just torque down with a torque wrench.

    I heard a...
  3. Replies
    32
    Views
    3,656

    I don't mind at all if a customer wants to order...

    I don't mind at all if a customer wants to order their own parts. (Here in NEPA we have many far-easterners who run tax-free convenience stores with the hopes of screwing as many as they can before...
  4. Replies
    59
    Views
    6,373

    We've found that the flareseals work really well....

    We've found that the flareseals work really well. A buddy of mine says they've been using them in nuclear work for years. they work esp. well for 410a mini's.
  5. Replies
    16
    Views
    2,508

    this one ended up being a power problem.

    this one ended up being a power problem.
  6. Replies
    16
    Views
    2,508

    I threw blade fuses in both outdoor units and...

    I threw blade fuses in both outdoor units and found one blown this morning after a lightning storm last night. Power company is going to put monitoring equip. on the meter as you suggested, though...
  7. Replies
    16
    Views
    2,508

    It was definitely an arc flash under the terminal...

    It was definitely an arc flash under the terminal cover on the unit. They had an electrician looking at the system and he is saying lightning strike caused this. I still have my doubts tho. It is an...
  8. Replies
    16
    Views
    2,508

    Sorry, I should have been more specific....

    Sorry, I should have been more specific. Yesterday I had 208v and 210v the two times I checked it. This morning I wound up with 215v at the unit. FlA was 12 and LRA showed 45 on Start.

    Supplier...
  9. Replies
    16
    Views
    2,508

    amps and voltage are ok. Its a semi-hermetic and...

    amps and voltage are ok. Its a semi-hermetic and I'm wondering if start windings are bad. Its an intermittent problem, hard one to pinpoint. we just had some bad storms thats what made me think it...
  10. Replies
    16
    Views
    2,508

    low temp 404a melting 'stuff'

    Hello, I have a wierd one. It's a 17 yr old (kold pak) low temp unit (404a) that we just replaced a timer, then a few weeks later all start components fried. This last weekend the start cap and relay...
  11. I was thinking about it. Maybe flush system and...

    I was thinking about it. Maybe flush system and replace comp oil and all new pipes. But then components are all still old. I think ill offer both and let customer choose. If it were me I'd prolly...
  12. Replies
    4
    Views
    1,622

    tbone steak recipe

    tried a new recipe on the grill that I would like to share. rub steaks in sea salt and pepper, then bathe them in red wine vinagrette dressing and add powdered garlic, splash of beer and drizzle a...
  13. repair or replace? that is the question

    I have a 16 yo carrier unit. Customer says it was diagnosed in January as having "crud in the pipes" and the company he had out blew 250 psi through the lines and it worked fine for a month or two....
  14. Replies
    22
    Views
    2,877

    Here are pics of the install. I added a lpsw as a...

    Here are pics of the install. I added a lpsw as a safety. Thanks for the input. Using the dryer as a receiver works great.
  15. Replies
    6
    Views
    622

    Roger that, ill keep you in mind.

    Roger that, ill keep you in mind.
  16. Replies
    22
    Views
    2,877

    I am going to install a filter/drier anyway and I...

    I am going to install a filter/drier anyway and I like the idea. I'll snap some pics when I'm done. I picked up the evap unit today. Had a little problem finding such a small tx. Sid harvey had a 1/4...
  17. Have you considered American Standard? They are...

    Have you considered American Standard? They are basically the same as a trane unit, in fact they share replacement parts and are made in the same factories without the big pricetag. AS has been...
  18. Replies
    7
    Views
    1,430

    Check this one out. I bought last year. Does gas,...

    Check this one out. I bought last year. Does gas, charcoal and has an optional side smoker for like 50 clams. When its fully assembled its like seven feet long and doesn't fit anywhere but it does a...
  19. Replies
    22
    Views
    2,877

    Just wondering how others approach the controls....

    Just wondering how others approach the controls. I could run low or line. It would be easiest to install a lpsw with nc to condenser unit. No defrost.

    On the cap tube, I thought about what you...
  20. Replies
    22
    Views
    2,877

    with the lp control, do I run a transformer and...

    with the lp control, do I run a transformer and 24 volt control or as line voltage?
  21. Replies
    22
    Views
    2,877

    switching from a cap tube I should be able to dx...

    switching from a cap tube I should be able to dx all the 1/4" line and come right off the evap with the 3/8" correct?
  22. Replies
    22
    Views
    2,877

    I am gently trying to steer them into a new box....

    I am gently trying to steer them into a new box. I told her today that I would be willing to bring the old one back to the shop and get it functioning as a backup.

    My plan was to install an...
  23. Replies
    12
    Views
    1,791

    I would give it it a drink, maybe an ounce or two...

    I would give it it a drink, maybe an ounce or two and see if head pressure changes. Is the suction line iced up?
  24. Replies
    8
    Views
    892

    It would probably pay you to upgrade to a new...

    It would probably pay you to upgrade to a new Carrier unit. As a Carrier dealer I would recommend the new Infinity system. It's pricey but it is modulating and will save you quite a bit on energy in...
  25. Replies
    11
    Views
    1,621

    Actually I was wrong, the set I have is the one...

    Actually I was wrong, the set I have is the one for 410a:

    http://www.hvacr-tools.com/mm5/merchant.mvc?Screen=PROD&Store_Code=HVACR&Product_Code=25200&Category_Code=MANIFOLDSGAUGES

    Same price...
Results 1 to 25 of 47