    Next time that happens boil a big pot of water to...

    Next time that happens boil a big pot of water to put some humidity in the air.
  2. Replies
    35
    Views
    1,538

    X2

    X2
  3. Replies
    27
    Views
    2,515

    X2

    X2
  4. Replies
    14
    Views
    2,938

    After it fills with water close the isolation...

    After it fills with water close the isolation valve for the water inlet(before the solenoid valve) and see what happens. It might be leaking by. When you unplugged the FS did it go into harvest? I do...
  5. Replies
    61
    Views
    3,820

    I have and use the TIF-ZX1 and it works very well...

    I have and use the TIF-ZX1 and it works very well for me. I have found some very small leaks with it. On walk-ins all I do is just open the door enough to stick the sensor in there and if there is a...
  6. Replies
    5
    Views
    2,007

    Depends on the air temp.

    Depends on the air temp.
  7. Replies
    10
    Views
    1,704

    X2

    X2
  8. Do you have anything in the utlilty room that is...

    Do you have anything in the utlilty room that is being pulled into the return? Bleach or other chemicals? Does it smell like your utility room?
  9. Replies
    42
    Views
    2,886

    Yep just had one like that.

    Yep just had one like that.
  10. Replies
    13
    Views
    1,153

    One easy way to check sight glass if unsure is...

    One easy way to check sight glass if unsure is just pump it down.
  11. Replies
    10
    Views
    3,980

    Did you look at the expansion vlv to see what...

    Did you look at the expansion vlv to see what kind of gas or run the compressor numbers by the supply house to see what it is? R409a you can drop right in an R12 rated system with out major changes....
  12. Replies
    7
    Views
    702

    Frosty Factory is ok also... ...

    Frosty Factory is ok also... http://www.frostyfactory.com/products.php
  13. Replies
    12
    Views
    3,637

    When in doubt change it out. I always replace the...

    When in doubt change it out. I always replace the LL drier when I open a system up.
  14. Thread: TXV Cloging

    by itsamine
    Replies
    23
    Views
    1,954

    The heat inside a kitchen (where most condensers...

    The heat inside a kitchen (where most condensers are located) will do more damage then brazing without nitrogen will ever do.
  15. Thread: TXV Cloging

    by itsamine
    Replies
    23
    Views
    1,954

    Filter not builder... damn driod.:whistle:

    Filter not builder... damn driod.:whistle:
  16. Replies
    7
    Views
    657

    Break cleaner.

    Break cleaner.
  17. Thread: TXV Cloging

    by itsamine
    Replies
    23
    Views
    1,954

    [QUOTE=VTP99;10231362] That's a100% proof it's...

    That's a100% proof it's from not using nitrogen. If that's the case wouldn't you see the screen clog alot faster?
  18. Thread: TXV Cloging

    by itsamine
    Replies
    23
    Views
    1,954

    It's more of the builder breaking down than...

    It's more of the builder breaking down than anything else.
  19. Thread: TXV Cloging

    by itsamine
    Replies
    23
    Views
    1,954

    Welp let it begin... I have never seen it or read...

    Welp let it begin... I have never seen it or read any documentation about this happening when nitrogen is not used. Please by all means show me the proof not the "theory" it could be. I would love to...
  20. Replies
    9
    Views
    2,344

    Sounds like an air leak but I would also check...

    Sounds like an air leak but I would also check the fan delay.
  21. Replies
    49
    Views
    3,293

    X2

    X2
  22. Replies
    11
    Views
    1,011

    No.

    No.
  23. Thread: E2 problem

    by itsamine
    Replies
    14
    Views
    1,071

    E2 is memory loss. Needs a new one.

    E2 is memory loss. Needs a new one.
  24. Replies
    9
    Views
    906

    It's from the water. The machine needs to be...

    It's from the water. The machine needs to be cleaned more often.
  25. Replies
    31
    Views
    2,211

    By no means I saying this is what happening but I...

    By no means I saying this is what happening but I has seen moisture reak havoc on systems. I have seen where it will form a ball of ice in the txv and screw evrything up. Then after awhile it melts...