Search:

Type: Posts; User: vics_zone

Search: Search took 0.00 seconds.

  1. Replies
    23
    Views
    4,122

    gotta keep low voltage circuits away from line...

    gotta keep low voltage circuits away from line voltage.
  2. Replies
    12
    Views
    2,885

    Rental! heck that is what landlords are for! if...

    Rental! heck that is what landlords are for! if you rent the place you should not have to deal with any of this hope you get a brake on your rent. so reversed polarity so was the motor runing in...
  3. Thread: Contracting

    by vics_zone
    Replies
    3
    Views
    703

    I understand but with limited resourses i need...

    I understand but with limited resourses i need somebody back me up plus I'm not much of a salesman my self this way they find the jobs etc...
  4. Replies
    13
    Views
    1,671

    I don't think you can ignore it fo you put...

    I don't think you can ignore it fo you put manometer on your two duct you will read anegative reading now when you add them together you are basiclly subtracting to a total of .5 static presure, as...
  5. Thread: Contracting

    by vics_zone
    Replies
    3
    Views
    703

    Does any body know or have them selfs done...

    Does any body know or have them selfs done contracting for sears and what did they think of it, are the conttracts properly bid and adecuate time aloted in for the jobs etc, just wondering looking to...
  6. Replies
    13
    Views
    1,671

    normally I would subtract those one is positive...

    normally I would subtract those one is positive and the other is negative. I dont have My duct chart with me but I rather have more return than not enought.
  7. Replies
    17
    Views
    2,106

    seems like an expensive way to get comfortable...

    seems like an expensive way to get comfortable but what I do see is the relationship with your way of thinking and where you live, here in Wisconsin heat pumps are not very comon they would only be...
  8. Replies
    23
    Views
    4,122

    I'm sorry did catch that last part what does the...

    I'm sorry did catch that last part what does the venting have to do with your voltage to the condenser, by the way that pipe might melt that drain, and I have to mention doesn't your utility co make...
  9. the other guys are right get a pro! but explore...

    the other guys are right get a pro! but explore all those options a damper with a switch that would let the furnace go on, you could insulated, there is also spec sheets provided by the manufacturer...
  10. Replies
    2
    Views
    806

    yes it does sound like the heat generated by that...

    yes it does sound like the heat generated by that heat strip would keep you fan running, there might be seperate breaker for heat strip and the actual fan try and turn just the heat strip of and see...
  11. Replies
    12
    Views
    2,885

    turtle is right!!!!!! you gotta match the rpm...

    turtle is right!!!!!! you gotta match the rpm that the squirrel cage makes not you motor who installed the new motor and were they equal, the motors I mean, did they then install a pulley the same...
  12. Replies
    13
    Views
    1,671

    that's the basic idea but even though you have...

    that's the basic idea but even though you have less square area there is other factors that play in to how much air is delivered, it also maters if you are trying to condition space in both seasons...
  13. Replies
    23
    Views
    4,122

    around here no lees than 4' from gas regulator,...

    around here no lees than 4' from gas regulator, and electric service. because there is potential for arc at the AC contactor and the regulator realeases gas occationally, that would of been a big...
  14. Replies
    33
    Views
    5,476

    is it missing a switch on the line voltage or...

    is it missing a switch on the line voltage or does not show where it is? big improvement. talk to your boos about how much time you'd save if you didn't have to make the wrap for coil, and the door,...
  15. Replies
    13
    Views
    1,238

    yeah! ok I was under the impresion that the unit...

    yeah! ok I was under the impresion that the unit ran that long and just never really warmed up. everything you said sounds right I would have to say that if you want it to kick into second stage just...
  16. Replies
    46
    Views
    3,070

    where is the original author and what happened to...

    where is the original author and what happened to this furnace? and yeah flame on, felt like nothing coming out, I did not catch it felt cold to the touch of the plenum, how far was the vent he was...
  17. Replies
    17
    Views
    2,106

    Electricity is often ran by power plants that...

    Electricity is often ran by power plants that operate or get there energy from fuel based source unless he's got a generator of a wind mill or water fall he's got and old defective system and half of...
  18. Replies
    46
    Views
    3,070

    I don't see how a box fan is going to draw more...

    I don't see how a box fan is going to draw more than the inducer in first place if the inducer does not run there woluld be no flame, he said there was water fron the condensating pipe, when you said...
  19. Replies
    13
    Views
    1,238

    Ok! Sorry what I meant was 2 stage furnaces with...

    Ok! Sorry what I meant was 2 stage furnaces with regular t-stat will kick in to 2nd stage in a x amount of time if wired properly. Now the infinity control will take multiple in-puts such as outside...
  20. Replies
    13
    Views
    1,238

    with infinity control you might have a set up...

    with infinity control you might have a set up that compares the outside temp and the temp your are at and the temp you are requiring and the control system it self would decide if its required to go...
  21. Replies
    13
    Views
    1,238

    I've installed plenty of carriers the t-stat...

    I've installed plenty of carriers the t-stat conectiones have w1 and w2 jumpered the furnace goes on to second stage after x min if you don't have the jumper and you have a special t-stat then the...
  22. Replies
    17
    Views
    2,106

    I agree in the comparison post cant go by price....

    I agree in the comparison post cant go by price.
    I don't see why he needs dual fuel if he instaled a two stage furnace and 17 year old HP probably a 8 seer unit or less. plus its got aleak which he...
  23. Replies
    46
    Views
    3,070

    the air gets blown in to the furnace thru the...

    the air gets blown in to the furnace thru the ducts not sucking it out its no diferent than the furnace fan the only diference is that its circulating basement air instead of upstairs air. And yeah...
  24. look at carrier's ussually the same squematics...

    look at carrier's ussually the same squematics but if you have voltage going in but not coming out typically that would be the board remember with those three wire switches you need the NO terminal...
  25. Replies
    13
    Views
    1,238

    Carriers two stage Furnaces will run 10 or 15min...

    Carriers two stage Furnaces will run 10 or 15min on first stage if T-stat is not satisfied in this time it should go in two second satage which pumps more gas in to the burners and ramps up rpm's on...
  26. Replies
    10
    Views
    1,789

    why are you looking at trane website? I thought...

    why are you looking at trane website? I thought you said these were Carrier units. They should be able to vent in a more practical location as long as they meet the standards ussually you deduct 5'...
  27. Replies
    17
    Views
    2,106

    that was going to be my first question!? get rid...

    that was going to be my first question!? get rid of the heat pump and install a condensing unit outside with a coil above your furnace 13 seer or better for about 3K or less. think about the stink of...
  28. Thread: 90+ venting

    by vics_zone
    Replies
    4
    Views
    706

    pipes should also be cleared from landscaping and...

    pipes should also be cleared from landscaping and obstruction, be ware the flue that is emited from the exhaust will kill part of any landscaping. In ideal situations the shorter the run the better.
  29. Replies
    46
    Views
    3,070

    hey! it's -35 degrees out and 60 inside and...

    hey! it's -35 degrees out and 60 inside and droping @ 12 mid night, I say what ever works other than a bonfire in the living room I've done this twice in emergencies and believe you me it does the...
  30. Replies
    38
    Views
    11,546

    the new models are much better, all brands have...

    the new models are much better, all brands have defects, consider the manufacturers warranty and you wont have any surprise costs also the contractor labor warranty and service policy a good...
  31. Replies
    46
    Views
    3,070

    sorry i missed that you were on the replacing...

    sorry i missed that you were on the replacing stages already, defenetly go with a two stage but make sure both gas and blower motor are variable, I think Trane does make one. defenetly, can not use a...
  32. Replies
    46
    Views
    3,070

    cold

    I live and work in the area and your right it was extremely cold, first I would like to mention that if you have flame and no hot air coming out your blower is not working the first thing you could...
Results 1 to 32 of 32
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event