    I have inserted the pleated filter in the...

    I have inserted the pleated filter in the EAC....I should leave it unplugged...correct?
  2. Replies
    21
    Views
    1,354

    Thanks...I inserted a 20x25x4 pleated filter into...

    Thanks...I inserted a 20x25x4 pleated filter into the slot where the electronic components reside in the Honeywell electronic air filter located inline at the air handler. I was told that was...
  3. Replies
    21
    Views
    1,354

    Thanks...I inserted a 20x25x4 pleated filter into...

    Thanks...I inserted a 20x25x4 pleated filter into the slot where the electronic filter components reside at the air handler...it is a MERV 12 rated filter. I also have a 20x30x1 in the return air...
  4. Replies
    21
    Views
    1,354

    Great info....so the obvious question is....what...

    Great info....so the obvious question is....what is the recommendation?

    The air handler has a Honeywell electronic air cleaner...would a pleated filter (20x25x4 1/2 MERV 12) in this unit be...
  5. Replies
    21
    Views
    1,354

    Although I appreciate your reply, it does no one...

    Although I appreciate your reply, it does no one any good to say something is a BIG PROBLEM unless you have the expertise to explain WHY....
  6. Replies
    21
    Views
    1,354

    I just checked the unit and it is a 4 ton...

    I just checked the unit and it is a 4 ton unit....so does that make a difference with the 20x30x1 filter?
  7. Replies
    21
    Views
    1,354

    Why will I be calling a contractor?

    Why will I be calling a contractor?
  8. Replies
    21
    Views
    1,354

    Thanks...are filters of that thickness readily...

    Thanks...are filters of that thickness readily available at a Home Depot or Lowe's?
  9. Replies
    21
    Views
    1,354

    Not quite sure what you mean...the Filtrete...

    Not quite sure what you mean...the Filtrete filter I am currently using is a 20x30x1 MERV 12 in a drop down grate from the ceiling. I presume the air handler is above that with the open hole where...
  10. Replies
    21
    Views
    1,354

    Electronic air filter question

    Just purchased a 10 year old home and discovered during the inspection that the air handler is new, but that there is a slot for an electronic air cleaner, but the slot is empty...meaning there is no...