Search:

Type: Posts; User: dhagar

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    549

    I am a contractor and have field installation...

    I am a contractor and have field installation checklist etc. Was just looking for more of a standard information form with remarks section that I could fill out in the field and give to buyer or...
  2. Replies
    8
    Views
    549

    Real Estate Sale Inspection / Service

    Does anyone have a form they would care to share for residential real estate inspections? :putergreet:
  3. Replies
    44
    Views
    5,322

    Good deal. I know I am working with tools the...

    Good deal. I know I am working with tools the pros use! Thank you again for all the information and to everyone that contributed!!!! I am a bit OCD and like things to be as close to perfect as...
  4. Replies
    44
    Views
    5,322

    Those are great references. Thank you so much!...

    Those are great references. Thank you so much! The HERS Rater site has alot of information I have been looking to find. I am in the process of familiarizing myself as much as possible with HERS and...
  5. Replies
    44
    Views
    5,322

    Based on the information supplied at this link I...

    Based on the information supplied at this link I was able to determine I am about 3.7 off from the desired temp split provided in the chart provided. Looks like I may have a bit of low airflow. Can...
  6. Replies
    44
    Views
    5,322

    Whoops!!! Yes I meant subcool.

    Whoops!!! Yes I meant subcool.
  7. Replies
    44
    Views
    5,322

    So found a couple of issues! One being that my...

    So found a couple of issues! One being that my low loss fitting was not allowing gauges to work properly. Changed fitting and now I have about 16 SH. Recovered charge and went just a bit overboard so...
  8. Replies
    44
    Views
    5,322

    @Mark Beiser i will have the unit charged...

    @Mark Beiser i will have the unit charged tomorrow as you have said. I will continue with the maintenance as spoken of by udarrell. The maintenance is a must regardless. Thank you all that have...
  9. Replies
    44
    Views
    5,322

    So blower has been cleaned thouroughly and gained...

    So blower has been cleaned thouroughly and gained about 1 degree of temp split between return and supply. Getting into the evap coil is going to be tricky. There is only about an 8" transition in...
  10. Replies
    44
    Views
    5,322

    Here it is from a couple of angles... 268831...

    Here it is from a couple of angles...

    268831
    268841
    268851
  11. Replies
    44
    Views
    5,322

    268781 Attached is pic of TXV. Thank you...

    268781

    Attached is pic of TXV.

    Thank you udarrell for clarifying! Amazing the differences in terminology I hear. I am familiar hearing cap tube, fixed orifice, and TXV. In reading I see alot of...
  12. Replies
    44
    Views
    5,322

    This TXV is definitely external. It sits just...

    This TXV is definitely external. It sits just outside the coil case as it is dripping condensate into the secondary pan. I will get a picture and post.

    So a piston orifice and cap tube are both...
  13. Replies
    44
    Views
    5,322

    No. This has a gas fired furnace. @Mr. Bill No...

    No. This has a gas fired furnace. @Mr. Bill No trick questions. After reading again, it does sound like it could be though. Just making sure the TXV or flowrater (now known to be a TXV thanks to...
  14. Replies
    44
    Views
    5,322

    268531 Hope this works...

    268531

    Hope this works...
  15. Replies
    44
    Views
    5,322

    Hmmm.. very interesting. So the outdoor unit...

    Hmmm.. very interesting. So the outdoor unit calls for a 90 piston and says Indoor TXV Subcooling 11. This coil is a slab and all I found for an orifice was a flowrater. The markings on the top are...
  16. Replies
    44
    Views
    5,322

    My apologies... I overlooked that question. AH =...

    My apologies... I overlooked that question.
    AH = 58RAV115-20
    Condenser = 38TRA048310

    Now that I am looking at the model numbers5 it seems the outside unit is a 4ton using a 5ton coil and a 5 ton...
  17. Replies
    44
    Views
    5,322

    Thank you for all the information!!! I will start...

    Thank you for all the information!!! I will start by having the evaporator coil cleaned and move from there as suggested. Will update on the progress!
  18. Replies
    1
    Views
    473

    Large Access Panel

    I have a heat pump in the "drop" ceiling, between floors, of an addition. The air handler is in a finished space above laundry equipment in the garage. I am trying to air seal where there is nothing...
  19. Replies
    44
    Views
    5,322

    I am the homeowner in this case. I however do...

    I am the homeowner in this case. I however do some AC work and am working with a mentor, that happens to be unavailable today.
  20. Replies
    44
    Views
    5,322

    Thank you for the reply udarrell! Using a...

    Thank you for the reply udarrell! Using a fieldpiece psycrometer I found the outdoor humdity to be about 55% and inside 46% . From the model number on the coil I found this to be a Accurater .90...
  21. Replies
    44
    Views
    5,322

    Looking at other posts I may not have supplied...

    Looking at other posts I may not have supplied enough info.

    Suction Pressure 70 Suction Line Temp 51
    Liquid Pressure 160 Liquid Line Temp 86
    Outdoor dB 82
    Indoor wB 68
  22. Replies
    44
    Views
    5,322

    Coil is a Carrier CE3AXA060000ABA. Looks to have...

    Coil is a Carrier CE3AXA060000ABA. Looks to have a Accurater metering device.
  23. Replies
    44
    Views
    5,322

    Normal Superheat - Zero SubCool

    :gah:Just had system serviced but system does not seem to be cooling. Checked temp diff from supply to return and was 10 degrees. So checked pressures at condenser. What does a normal superheat (10...
  24. Replies
    9
    Views
    1,005

    Thank you for the information! I am in N....

    Thank you for the information! I am in N. Louisiana. We see quite a bit of humidity so leaning towards the VS. There is a significant cost difference though and not sure if it would pay off to go...
  25. Replies
    9
    Views
    1,005

    Goodman Central A/C

    Would like some advice on the air handler options for Goodman. I have the choice of an EEM or PSC motor. What would be the pro's and con's of each and recommended option? :limb:
Results 1 to 25 of 31
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event