Search:

Type: Posts; User: firedup

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Thread: POOL PAKS ?

    by firedup
    Replies
    2
    Views
    682

    paks

    looked futher into the ecc program there set up two by two feeding the same duct both are set up differently, Anyway its just going to take more time to get them right . mostly years of abuse ...
  2. Thread: POOL PAKS ?

    by firedup
    Replies
    2
    Views
    682

    POOL PAKS ?

    ANYONE WORK ON THESE UNITS ,THE ONES I'M WORKING ON MODEL 100-7E, USE STEAM COILS ,STEAM CONTROLLER HAS MELTED INSIDE UNIT, R-22 TWO STAGES DUNAM BUSH CONDENSERS LOW ON GAS ,POOL PUMPS LOCKED UP,...
  3. Replies
    5
    Views
    4,210

    frazer-johnson,luxair,colman,york same company....

    frazer-johnson,luxair,colman,york same company. There the same on the inside
  4. Replies
    16
    Views
    1,437

    NOPE! just like a lot of things I've come across...

    NOPE! just like a lot of things I've come across lately seem strange. but we all know the stuff is out there.Now a days you can buy it Shoot it In it's all good ????.. what the heck its only money....
  5. Replies
    16
    Views
    1,437

    cut open the old dryer it was still in-tacked....

    cut open the old dryer it was still in-tacked. pressures would go to 350 and cut out on safety. ? would super seal turn into a fine powder inside a r 404 system ?
    I'am totally lost as to what caused...
  6. Replies
    16
    Views
    1,437

    safety cut out at 400. unit was off on safety....

    safety cut out at 400. unit was off on safety. headmaster loaded with with powder the spring was totally full of it. the txv screen was plugged , the equipment is 4 yrs old same as building. filter...
  7. Replies
    16
    Views
    1,437

    blown out filter dryer

    filter dryer blew desiccant through r- 404 system. Took out headmaster and and txv! How do you make sure desiccant is out of the system? the refer rack is on the fourth floor the evap on the first. ...
  8. Replies
    15
    Views
    2,132

    CHILLED BEAMS

    I WAS ALSO INFORMED ,THE BUILDING WILL HAVE "JCI" CONTROLLES:eek2:
  9. Thread: Micron what?

    by firedup
    Replies
    26
    Views
    4,266

    A GOOD REFRIGERANT SUPPLY HOUSE, THE COUNTER GUYS...

    A GOOD REFRIGERANT SUPPLY HOUSE, THE COUNTER GUYS KNOW YOU ,THEY TEND TO HAVE SOME FUN WITH YOU,BUT MOST NOT ALL KNOW THIER STUFF. IF YOU GO TO A RESIDENICAL SUPPLYER AND ASK FOR A MICRON GAUGE OR A...
  10. Replies
    16
    Views
    3,265

    COME ON YOU ALL KNOW THE CABNIT INSTALLER DID...

    COME ON YOU ALL KNOW THE CABNIT INSTALLER DID THIS! LOOK IT'S DUCT TAPE:eek2:
  11. Replies
    20
    Views
    2,710

    THIS HAS GOT TO BE A JOKE, BECAUSE IT SHOULD BE...

    THIS HAS GOT TO BE A JOKE, BECAUSE IT SHOULD BE CONDEMMED IT WHAY PAST IT USEFUL LIFE:bump:
  12. Replies
    15
    Views
    2,132

    RADIANT COOLING??

    THERE INSTALLING RADIANT COOLING PANELS IN THE CEILING ,AKA CHILLED BEAMS ,IN A 7 STORIE HIGH RISES WERE I WORK. IVE SEEN SOME ENGINEERING DATA ABOUT THE PANELS, 60 DEGREES WATER,= X # BTU REMOVED ....
  13. Replies
    43
    Views
    3,561

    YES THE SYSTEM IS EMPTY AND IN A VACUUM

    YES THE SYSTEM IS EMPTY AND IN A VACUUM
  14. Replies
    43
    Views
    3,561

    LIQUID CHARGING

    to fast charged a semi- hermetic system, r-22 holds about 15lb should you dump liquid in both suction line and the receiver let stand 15 Min's then start up unit,I've never done this! Is this...
  15. Thread: Ozone

    by firedup
    Replies
    13
    Views
    820

    its all smoke and mirrors,and profit for big...

    its all smoke and mirrors,and profit for big business. recover is a must!!!
  16. Replies
    25
    Views
    1,173

    HAVE BOTH

    THEN YOU'LL BE THE CONTRACTOR OF RECORD FOR THAT SCHOOL? WHY DO THEY NEED IT? I'VE USED MY LICENSE FOR OTHER BUSINESS WERE IVE WORKED AND NOT SIGNED OVER MY LICENSE. IF THEY NEED A PERMIT, THEN YOU...
  17. Replies
    6
    Views
    1,511

    HUMIDISTAT IS LEVEL

    HUMIDISTAT IS LEVEL
  18. Replies
    11
    Views
    2,921

    best I heard in alone while,ouch!

    best I heard in alone while,ouch!
  19. Replies
    74
    Views
    8,201

    Poll: dyes

    LOVE HATE RELATION ,MESSAY, YOU PUT IT IN IT FINDS THE LEAK,MUST BE ALOUDED TO RUN THRU SYSTEM 24 HOURS ALWAY FINES THE LEAK THE GLASSES HELP LOCATE LEAK :eek:
  20. Replies
    4
    Views
    446

    I'LL LOOK THANK YOU

    I'LL LOOK THANK YOU
  21. Replies
    4
    Views
    446

    i have old and new monted on peg board ,also...

    i have old and new monted on peg board ,also saved few old t sats
  22. Replies
    4
    Views
    446

    collector of old furnace emblems

    any one else collect old manufactures furnace emblems... muller, afco,gorden they dont like the use too
  23. Replies
    28
    Views
    3,402

    good work/always learning from others

    see what others do and copy good work. not fun working in a closet or in the crawl space. ? is gas coak legal, is the gas coak w.o.g. ? were do condensate drains end,is a/c 410a
  24. Replies
    18
    Views
    2,940

    good work

    great job , I prefer patio stones to wood. 13 seer 410a filter dryer?
  25. Replies
    339
    Views
    45,135

    DETROIT MI. AREA GO RED WINGS ! 25YEARS AND...

    DETROIT MI. AREA GO RED WINGS ! 25YEARS AND STILL LEARNING ?WINDOW SHAKERS WALK IN AND UP TO CASCADE SYSTEMS, CHILLERS, I LOVE TO FREEZE STUFF -20, HVAC CAN BE FUN TO VARY HARD AND TRYING. IN THIS...