  1. Replies
    4
    Views
    1,325

    since i got my new phone

    330991331001331011331021331031331041330981


    the first 5 are this messed up install at a 12 year old building complex we service only for a few years, i guess i was the first one to notice...
  2. Replies
    17
    Views
    2,070

    everytime we do a new coil with r-22 cond. it...

    everytime we do a new coil with r-22 cond. it always comes with 410a metering device txv or orifice, we always take it out and install an r-22 txv for the correct tonnage had no problems with that......
  3. Replies
    9
    Views
    2,095

    wow yeah well i guess this guy worked at a supply...

    wow yeah well i guess this guy worked at a supply house and got this cheap along with a nother single split that had a square evap. which iv never seen and it came prebroken but he did not care, my...
  4. Replies
    9
    Views
    2,095

    R-22 LG MultiSplit

    Customer purchased cond. and evaps. had us put it in, system still had r-22 charge in it. i thought it came out nice so im making my first post :grin2:
  5. Replies
    13
    Views
    1,426

    :whistle: the gas is shut off, no problems here

    :whistle: the gas is shut off, no problems here
  6. Replies
    63
    Views
    4,247

    its pretty slow here in southern RI i started...

    its pretty slow here in southern RI i started November 2011 and it was a bit busier last year, only 4 service calls past 2 days, still got shop work but i want more service! its been so warm here
  7. Replies
    8
    Views
    3,176

    you guys ever see this?

    During this summer i went to a call saying that the line was freezing up, i of coarse went thinking it must be the suction line. NOPE it was the liquid line. it was fairly obvious problem though on...
  8. Replies
    7
    Views
    548

    below 130degree flue gasses that wont happen at...

    below 130degree flue gasses that wont happen at 80% tho check the flue gas
  9. Replies
    17
    Views
    2,969

    gotta love the easy calls

    gotta love the easy calls
  10. Thread: Easy access

    by RIGUY
    Replies
    14
    Views
    2,173

    i love when there 2 condensing unit an inch apart...

    i love when there 2 condensing unit an inch apart and one inch on every side. it makes for some good ol' fashion back breaking labor to just get your gauge on =)
  11. Thread: drain lines

    by RIGUY
    Replies
    16
    Views
    1,090

    is the outlet of the p-trap lower than the inlet?

    is the outlet of the p-trap lower than the inlet?
  12. combustion analyzer or old school combustion test...

    combustion analyzer or old school combustion test kit and knowing what your looking for in terms of your measurements. You will succeed. look for cracks in the heat exchanger and look at the flame...
  13. Replies
    10
    Views
    640

    set up a camera, did this happen just recently or...

    set up a camera, did this happen just recently or has it been getting worse?
  14. Replies
    2
    Views
    222

    call your local HVAC company they will have...

    call your local HVAC company they will have and/or get what you want.
  15. Replies
    16
    Views
    728

    ill just say ten wrap

    ill just say ten wrap
  16. Replies
    10
    Views
    457

    check pressures

    check pressures
  17. Replies
    6
    Views
    431

    if the condenser is one year old it should be...

    if the condenser is one year old it should be warrantied so call lennox or local hvac company and check on that if so replace but first make sure it is the compressor that is bad so call local hvac...
  18. Replies
    14
    Views
    2,089

    what size is the house, what is the td across the...

    what size is the house, what is the td across the coil, what are the pressures, and did you check for loose returns in the attic sucking in 100 degree air with lots of humidity, also are all the...
  19. Replies
    14
    Views
    1,136

    so the answer is yes its okay to use c02 while...

    so the answer is yes its okay to use c02 while brazing but Nitrogen is best?
  20. Replies
    8
    Views
    881

    never seen a tube within a tube in AC let me know...

    never seen a tube within a tube in AC let me know how it works out, usually just use individual lines insulated separately. post a pic of this line set please
  21. Replies
    18
    Views
    753

    2nd that clean that condenser with condenser...

    2nd that clean that condenser with condenser cleaner and water not just one or the other mixem up.:gah:
  22. Replies
    14
    Views
    1,136

    using C02 instead of Nitrogen??

    is this okay to do, we do not carry nitrogen but have C02 i was just wondering if since they are both inert gasses can i run c02 while brazing??
  23. Replies
    6
    Views
    1,107

    i would recommend adding a hard start kit and...

    i would recommend adding a hard start kit and seeing if the amps are within the rated LRA on start up.
  24. Replies
    4
    Views
    354

    if the blower inside is on and the compressor and...

    if the blower inside is on and the compressor and condenser fan motor are on when the thermostat is in cool then id say refrigerant problem, call local service co. if it needs refrigerant make sure...
  25. Thread: Best thermometer

    by RIGUY
    Replies
    11
    Views
    995

    thank you all i have went through 3 thermometer...

    thank you all i have went through 3 thermometer since staring in November, i just want a digital thermometer that can come through for me when i need her most, 130 degree attic no walkway all that...