07-09-2009, 09:00 AM
Thread: chiller abnormal noise
by techtalker- Replies
- 15
- Views
- 764
20 PSI in the condenser on a low pressure chiller...
20 PSI in the condenser on a low pressure chiller is not normal. If the purge is not working, then get it fixed. It sounds like your chiller is surging due to air in the system.
-
04-18-2009, 12:23 PM
Thread: High Discharge Temp Trip
by techtalker- Replies
- 11
- Views
- 1,043
Does this 19Dr have two compressors on it ? Is...
Does this 19Dr have two compressors on it ? Is the discharge temp high when both compressors are on, or doesn't it matter ?
-
03-23-2009, 10:21 AM
Thread: Carrier HXA Piping
by techtalker- Replies
- 2
- Views
- 391
Yes. Double risers are used on these units,...
Yes. Double risers are used on these units, depending on the height, pipe size, etc. Separators are not 100% efficient. The piping needs to be correctly sized. Carrier has a refrigerant piping...
-
03-05-2009, 10:27 AM
Thread: CALL THE COPS
by techtalker- Replies
- 51
- Views
- 2,983
And York says that Hermetic motors are a sure way...
And York says that Hermetic motors are a sure way to contaminate your whole refrigerant charge, and Carrier says that 123 is going to kill us all..
Jeez - this thread is just junk. -
02-27-2009, 04:39 PM
Thread: 19dk
by techtalker- Replies
- 21
- Views
- 926
for your enjoyment here are a few pics from an...
for your enjoyment here are a few pics from an operational Trane screw chiller 460VAC 400A. Terminals totally covered and bridged with a solid block of ice. Creepy! Not at all relevant to the...
-
02-24-2009, 04:40 PM
Thread: 19xr pic lll won't clear fault
by techtalker- Replies
- 2
- Views
- 319
I always hate to say this, but .... Did you...
I always hate to say this, but ....
Did you press the reset softkey ? (It should be highlighted)
What is the message on the default display screen? Is it low evap temperature ? If so, there... -
01-12-2009, 08:55 AM
Thread: NEED TRAINING ON CARRIER 19XR
by techtalker- Replies
- 11
- Views
- 3,445
Contact the Replacement components division of...
Contact the Replacement components division of Carrier in Syracuse. 315-433-4226. Tell them the serial number of the machine in question and they will fax you the perfomance data for the machine. ...
-
12-12-2008, 09:29 AM
Thread: Carrier 30HXC096 Chiller Oil analysis
by techtalker- Replies
- 14
- Views
- 963
You have to remember that this chiller uses POE...
You have to remember that this chiller uses POE oil, with loves moisture. Its very easy for the oil, if left open to atmosphere to become contaiminated.
-
12-11-2008, 07:52 AM
Thread: Carrier 19DK Chiller problem
by techtalker- Replies
- 45
- Views
- 2,739
taking apart the pump is not all that difficult. ...
taking apart the pump is not all that difficult. My guess is that the main bushing (No bearings in the pump) is probalby gone. Look at the parts book to see if you can get individual parts instead...
-
12-03-2008, 08:55 AM
Thread: Copeland Application R-22 to other ref
by techtalker- Replies
- 0
- Views
- 338
Copeland Application R-22 to other ref
I saw this application bulletin come in from Copeland compressor, and I thought all of you should be aware....:)
NO: MB2008CC-40
DATE: 12/1/2008
TO: Air Conditioning Original Equipment... -
12-03-2008, 08:46 AM
Thread: "cold beam" cooling
by techtalker- Replies
- 6
- Views
- 2,070
it can work, just make sure that the building...
it can work, just make sure that the building stays dehumidified. Otherwise, if the humidity is high in the space, the cold beams can condense the moisture out, and there are no drip pans on these...
-
11-07-2008, 08:22 AM
Thread: permafrost??
by techtalker- Replies
- 19
- Views
- 3,282
One of the main claims of this "snake oil" is...
One of the main claims of this "snake oil" is that the "polarized molecules" of the additive bond to the heat transfer surfaces and improve boiling heat transfer performance by removing oil fouling...
-
11-07-2008, 08:15 AM
Thread: permafrost??
by techtalker- Replies
- 19
- Views
- 3,282
Boy this stuff keeps on coming around in...
Boy this stuff keeps on coming around in different forms !!:eek:
please see this link: http://www.refrigtech.com/magic.html
I've said other things about these types of additives in older... -
08-14-2008, 03:00 PM
Thread: Trane Screw phase loss
by techtalker- Replies
- 2
- Views
- 520
That's a RTH sccrew....
That's a RTH sccrew....
-
08-14-2008, 02:41 PM
Thread: Trane Screw phase loss
by techtalker- Replies
- 2
- Views
- 520
Trane Screw phase loss
I have a Trane screw unit, RBH 150, that is going into phase loss alarm before the compressor can even try to start. Any ideas out there ?
-
08-13-2008, 09:50 AM
Thread: Maximum circuit size
by techtalker- Replies
- 6
- Views
- 588
section 440-22 of the code, section C states that...
section 440-22 of the code, section C states that the protective device rating will not exceed the manufacturer's values. so the electrician need to read a little bit further.
-
07-31-2008, 05:29 PM
Thread: GPM problem???
by techtalker- Replies
- 11
- Views
- 849
If your inlet and outlet water pressures are the...
If your inlet and outlet water pressures are the same, then you don't have any flow through the coil. Start looking for a bad valve, snapped shafts can sometimes fool ya.
-
11-15-2007, 09:21 PM
Thread: Condensor Water Treatment
by techtalker- Replies
- 2
- Views
- 703
Look at the top of the web site and do a search...
Look at the top of the web site and do a search for "Dolphin". It is not anything you want to use.
-
10-17-2007, 08:47 AM
Thread: Wtf?
by techtalker- Replies
- 10
- Views
- 1,136
That used to be a problem way back when. I...
That used to be a problem way back when. I remember tying in generators while working on board merchant ships. You'd have to look at the light bulbs and make your timing just right.
Now with... -
10-17-2007, 08:44 AM
Thread: District Cooling Chiller Plant
by techtalker- Replies
- 11
- Views
- 2,879
This is our past. There are plenty of district...
This is our past. There are plenty of district heating and cooling plants out there. most of them supplying chilled water to hospitals, universities, county and state gov. etc. Example: The TECO...
-
10-15-2007, 02:52 PM
Thread: Wtf?
by techtalker- Replies
- 10
- Views
- 1,136
HFC -134a
HFC -134a
-
10-12-2007, 10:11 AM
Thread: Bearing failure due to VFD
by techtalker- Replies
- 39
- Views
- 4,150
consolidmech - I don't know where you got your...
consolidmech - I don't know where you got your information from, but there is no change to the bearings of a 19XR whether or not it has a vfd on it or not.
-
10-12-2007, 10:01 AM
Thread: Waxing in Centrifugal
by techtalker- Replies
- 9
- Views
- 973
More than likely suspects to your problem: ...
More than likely suspects to your problem:
1) Machine has been wet
or
2) Someone is using the wrong oil for the unit -
10-12-2007, 09:58 AM
Thread: Wtf?
by techtalker- Replies
- 10
- Views
- 1,136
These units are now getting installed in Alaska. ...
These units are now getting installed in Alaska. And yes, it is derived from Carrier 19XR.
-
10-10-2007, 08:09 AM
Thread: coelescers
by techtalker- Replies
- 1
- Views
- 329
I would look at a Dollinger system: ...
I would look at a Dollinger system: http://www.dollinger-spx.com
most of the manufacturer's use them for their components on their screw chillers.