    20 PSI in the condenser on a low pressure chiller...

    20 PSI in the condenser on a low pressure chiller is not normal. If the purge is not working, then get it fixed. It sounds like your chiller is surging due to air in the system.
  2. Replies
    11
    Views
    1,043

    Does this 19Dr have two compressors on it ? Is...

    Does this 19Dr have two compressors on it ? Is the discharge temp high when both compressors are on, or doesn't it matter ?
  3. Replies
    2
    Views
    391

    Yes. Double risers are used on these units,...

    Yes. Double risers are used on these units, depending on the height, pipe size, etc. Separators are not 100% efficient. The piping needs to be correctly sized. Carrier has a refrigerant piping...
  4. Replies
    51
    Views
    2,983

    And York says that Hermetic motors are a sure way...

    And York says that Hermetic motors are a sure way to contaminate your whole refrigerant charge, and Carrier says that 123 is going to kill us all..

    Jeez - this thread is just junk.
  5. Thread: 19dk

    by techtalker
    Replies
    21
    Views
    926

    for your enjoyment here are a few pics from an...

    for your enjoyment here are a few pics from an operational Trane screw chiller 460VAC 400A. Terminals totally covered and bridged with a solid block of ice. Creepy! Not at all relevant to the...
  6. Replies
    2
    Views
    319

    I always hate to say this, but .... Did you...

    I always hate to say this, but ....

    Did you press the reset softkey ? (It should be highlighted)

    What is the message on the default display screen? Is it low evap temperature ? If so, there...
  7. Replies
    11
    Views
    3,445

    Contact the Replacement components division of...

    Contact the Replacement components division of Carrier in Syracuse. 315-433-4226. Tell them the serial number of the machine in question and they will fax you the perfomance data for the machine. ...
  8. Replies
    14
    Views
    963

    You have to remember that this chiller uses POE...

    You have to remember that this chiller uses POE oil, with loves moisture. Its very easy for the oil, if left open to atmosphere to become contaiminated.
  9. Replies
    45
    Views
    2,739

    taking apart the pump is not all that difficult. ...

    taking apart the pump is not all that difficult. My guess is that the main bushing (No bearings in the pump) is probalby gone. Look at the parts book to see if you can get individual parts instead...
  10. Replies
    0
    Views
    338

    Copeland Application R-22 to other ref

    I saw this application bulletin come in from Copeland compressor, and I thought all of you should be aware....:)

    NO: MB2008CC-40
    DATE: 12/1/2008
    TO: Air Conditioning Original Equipment...
  11. Replies
    6
    Views
    2,070

    it can work, just make sure that the building...

    it can work, just make sure that the building stays dehumidified. Otherwise, if the humidity is high in the space, the cold beams can condense the moisture out, and there are no drip pans on these...
  12. Replies
    19
    Views
    3,282

    One of the main claims of this "snake oil" is...

    One of the main claims of this "snake oil" is that the "polarized molecules" of the additive bond to the heat transfer surfaces and improve boiling heat transfer performance by removing oil fouling...
  13. Replies
    19
    Views
    3,282

    Boy this stuff keeps on coming around in...

    Boy this stuff keeps on coming around in different forms !!:eek:

    please see this link: http://www.refrigtech.com/magic.html

    I've said other things about these types of additives in older...
  14. Replies
    2
    Views
    520

    That's a RTH sccrew....

    That's a RTH sccrew....
  15. Replies
    2
    Views
    520

    Trane Screw phase loss

    I have a Trane screw unit, RBH 150, that is going into phase loss alarm before the compressor can even try to start. Any ideas out there ?
  16. Replies
    6
    Views
    588

    section 440-22 of the code, section C states that...

    section 440-22 of the code, section C states that the protective device rating will not exceed the manufacturer's values. so the electrician need to read a little bit further.
  17. Replies
    11
    Views
    849

    If your inlet and outlet water pressures are the...

    If your inlet and outlet water pressures are the same, then you don't have any flow through the coil. Start looking for a bad valve, snapped shafts can sometimes fool ya.
  18. Replies
    2
    Views
    703

    Look at the top of the web site and do a search...

    Look at the top of the web site and do a search for "Dolphin". It is not anything you want to use.
  19. Thread: Wtf?

    by techtalker
    Replies
    10
    Views
    1,136

    That used to be a problem way back when. I...

    That used to be a problem way back when. I remember tying in generators while working on board merchant ships. You'd have to look at the light bulbs and make your timing just right.

    Now with...
  20. Replies
    11
    Views
    2,879

    This is our past. There are plenty of district...

    This is our past. There are plenty of district heating and cooling plants out there. most of them supplying chilled water to hospitals, universities, county and state gov. etc. Example: The TECO...
  21. Thread: Wtf?

    by techtalker
    Replies
    10
    Views
    1,136

    HFC -134a

    HFC -134a
  22. Replies
    39
    Views
    4,150

    consolidmech - I don't know where you got your...

    consolidmech - I don't know where you got your information from, but there is no change to the bearings of a 19XR whether or not it has a vfd on it or not.
  23. Replies
    9
    Views
    973

    More than likely suspects to your problem: ...

    More than likely suspects to your problem:

    1) Machine has been wet
    or
    2) Someone is using the wrong oil for the unit
  24. Thread: Wtf?

    by techtalker
    Replies
    10
    Views
    1,136

    These units are now getting installed in Alaska. ...

    These units are now getting installed in Alaska. And yes, it is derived from Carrier 19XR.
  25. Thread: coelescers

    by techtalker
    Replies
    1
    Views
    329

    I would look at a Dollinger system: ...

    I would look at a Dollinger system: http://www.dollinger-spx.com

    most of the manufacturer's use them for their components on their screw chillers.