Search:

Type: Posts; User: RACLman

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    35
    Views
    2,416

    If it's still available I would like a copy as...

    If it's still available I would like a copy as well.

    TIA
  2. Did this stick come with Lon or BACnet?

    Did this stick come with Lon or BACnet?
  3. Replies
    3
    Views
    240

    No RC-Studio front end at the site but all VAV...

    No RC-Studio front end at the site but all VAV boxes have SSL's with LCD Displays.

    Thanks
  4. Replies
    3
    Views
    240

    Reliable MACH Air Balancing

    Does anyone have any documentation or detailed procedures for performing an air balance on a Reliable Controls MACH Air VAV controller?

    Any help would be greatly appreciated.

    Thanks
  5. Replies
    2
    Views
    279

    nviTodEvent_timeToNextState needs to be set to a...

    nviTodEvent_timeToNextState needs to be set to a value greater than zero.
  6. Thread: SymmetrE

    by RACLman
    Replies
    5
    Views
    287

    When using SymmetrE I have found that you should...

    When using SymmetrE I have found that you should image your machine before making any significant changes. It gives you a fallback position in case of a catastrophe :)
  7. Vykon is the direct sales channel for Tridium.

    Vykon is the direct sales channel for Tridium.
  8. Replies
    4
    Views
    479

    They are Honeywell W7751B XL10 VAV controllers.

    They are Honeywell W7751B XL10 VAV controllers.
  9. Replies
    281
    Views
    42,408

    Controltec, if it's not too much trouble I would...

    Controltec, if it's not too much trouble I would like to get a copy of the manuals as well.
    Thanks
  10. Replies
    23
    Views
    2,931

    If you had the XL10 configuration screen...

    If you had the XL10 configuration screen available in AX then the Wizards are already installed on the JACE. The Commit button only saves the changes to the AX database, you will still have to...
  11. Replies
    23
    Views
    2,931

    If you already have a complete database in AX why...

    If you already have a complete database in AX why would you want to bring Lonspec into the picture. Why not just load the Ax Wizards on the JACE and modify the XL10's
    in your AX database. Seems...
  12. Thread: AX custom tree

    by RACLman
    Replies
    49
    Views
    5,587

    I would like a copy as well if it's not too much...

    I would like a copy as well if it's not too much trouble.

    Thanks
  13. Replies
    9
    Views
    895

    As of 2009 when the App was last updated it was...

    As of 2009 when the App was last updated it was not compatible with Rapid Balance. It does have instructions on how to perform the balance proceedure included in the App's documentation.
  14. Thread: ABB LON Drive

    by RACLman
    Replies
    21
    Views
    2,046

    I believe it is found in the snvt nvoStatus and...

    I believe it is found in the snvt nvoStatus and is called manualControl. False = Auto, True = Manual
  15. Thread: JCI PCT VMWARE

    by RACLman
    Replies
    4
    Views
    617

    Just received my e6520 2-weeks ago. The legacy...

    Just received my e6520 2-weeks ago. The legacy port replicator attaches
    to the docking station connector on the bottom of the laptop. has worked
    perfectly so far.
  16. Replies
    3
    Views
    344

    Thanks for the responses. Unfortunately I am...

    Thanks for the responses. Unfortunately I am unable to upgrade the 3.08 LNS database as another contractor is also working on the system as part of a phased upgrade of the controls. The other...
  17. Replies
    3
    Views
    344

    2 versions of LNS on same PC

    Is it possible to run LNS Turbo on a Windows 7 PC with another version of LNS (3.08) running on a virtual Windows XP OS on the same PC?

    Will the two coexist or will they hose each other up?
  18. Replies
    8
    Views
    1,185

    I believe the BACnet Spyders auto adjust thier...

    I believe the BACnet Spyders auto adjust thier baud rate to the JACE when they power up. Cycle the power to the Spyders with the JACE up and online and they should syncronize themselves with the...
  19. Thread: CSI TO AX

    by RACLman
    Replies
    5
    Views
    647

    Ditto on Quicksilvers Driver. Works well.

    Ditto on Quicksilvers Driver. Works well.
  20. Replies
    23
    Views
    4,063

    I also was certified in 06, back then the highest...

    I also was certified in 06, back then the highest score was a 149. Go figure.
  21. Replies
    13
    Views
    802

    Hope everyone has a safe and happy holiday

    Hope everyone has a safe and happy holiday
  22. Replies
    5
    Views
    764

    LonSpec v5.1.5 does support MS Windows Vista and...

    LonSpec v5.1.5 does support MS Windows Vista and is available for download on the Honeywell Buildings Forum website.
  23. The VAV1 or "1000 Series" XL10 VAV controller is...

    The VAV1 or "1000 Series" XL10 VAV controller is not compatible with RapidBalance. The VAV1 pre-dates the use of E-Vision. This controller was programmed and commissioned directly thru the Zone...
  24. Replies
    8
    Views
    2,826

    Honeywell has a Lonworks based package called...

    Honeywell has a Lonworks based package called RapidZone for VVT. It's simple to setup but requires an external dry contact closure for scheduling as the AHU/RTU controller (XL15C) has no real time...
  25. Thread: LON over IP

    by RACLman
    Replies
    24
    Views
    2,729

    That sounds dangerous, sharing anything with EBI...

    That sounds dangerous, sharing anything with EBI is problematic at best. How many lon channels are you dealing with and where does the 600 reside in all this?