Search:

Type: Posts; User: jim bergmann

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    51
    Views
    1,764

    No, it is not. It is a tough model with three...

    No, it is not. It is a tough model with three tier distribution in the UK. But with the need for international support it is necessary. Soon we will be translated into German, French and Italian and...
  2. Replies
    51
    Views
    1,764

    Contact Advanced Engineering. They are a master...

    Contact Advanced Engineering. They are a master distributor for Imperial in the UK. They have stock of the iManifold and iConnect and probes.

    The iManifoldis doing well in the UK, and has won...
  3. Replies
    352
    Views
    25,447

    Kevin, right now we are not supporting multiple...

    Kevin, right now we are not supporting multiple superheats off a single pressure. I am hoping to have that out in the next update. The current multi-circuit mode allows you to do up to 6 circuits of...
  4. Replies
    352
    Views
    25,447

    Tech connect has always been part of the basic...

    Tech connect has always been part of the basic cloud service, it was never 'free", as Tech Connect transmits and receives data it does use some bandwidth and requires some support on our end to...
  5. Replies
    352
    Views
    25,447

    Unlimited

    Unlimited
  6. Replies
    352
    Views
    25,447

    The application is free, and will always be free....

    The application is free, and will always be free. We are adding in cloud services to store your data and tech connect as part of that to stream your data out to another technician. Those are paid...
  7. I have seen that a few times even with other...

    I have seen that a few times even with other brands. I would recommend Appion core tools. They really make the best in the industry at the moment. They work well on everything. I do not think you...
  8. Replies
    352
    Views
    25,447

    Not yet, but soon. Right now they need to be...

    Not yet, but soon. Right now they need to be zeroed out one at a time. The good news is it is not required frequently. The probes have excellent long term stability and unless you remove them from...
  9. Replies
    352
    Views
    25,447

    They can all be zeroed in the wireless probe...

    They can all be zeroed in the wireless probe menu. We just have a tight dead band because the sensor is actually calibrated. They should not drift too far off zero over there lifetime.
  10. Replies
    352
    Views
    25,447

    OK, that helps. I will look at it when we get it...

    OK, that helps. I will look at it when we get it back. We have a very tight tolerance on allowable zeroing because all of the sensors are calibrated and temperature compensated.


    Jim
  11. Replies
    352
    Views
    25,447

    Kevin, You can use the probe for oil pressure,...

    Kevin,

    You can use the probe for oil pressure, no problem there. Was it reading vacuum under pressure or at atmospheric? If at atmospheric pressure, you likely only needed to zero out the probe....
  12. Replies
    23
    Views
    973

    We typically get right at 400' los with the...

    We typically get right at 400' los with the iManifold, and generally at least 100-200' under typical construction conditions. With the iConnect and Zigbee, we can do a lot more because of the mesh...
  13. Replies
    32
    Views
    1,467

    High voltage diodes

    High voltage diodes
  14. Replies
    32
    Views
    1,467

    Even when you stop charging, there is still...

    Even when you stop charging, there is still residual static. Until it is fully discharged it will affect the readings. Static electricity can be generated at such a high voltages it will also destroy...
  15. Replies
    32
    Views
    1,467

    Grounding the condenser is not the issue. Your...

    Grounding the condenser is not the issue. Your hoses are rubber, connected to your gauges that build a static charge as refrigerant flows through them. When the static charge becomes high enough, it...
  16. Replies
    32
    Views
    1,467

    Here is some good material on the subject....

    Here is some good material on the subject. Biggest reason k-type is no good for digital manifolds is noise generated by static electricity generated by flowing refrigerant
    ...
  17. Replies
    352
    Views
    25,447

    There are a few easter eggs hidden in the...

    There are a few easter eggs hidden in the software.
  18. Replies
    352
    Views
    25,447

    We will have to ship one out. It comes with the...

    We will have to ship one out. It comes with the production units, it is not an available "accessory" Contact me via email with a ship to address.

    Thanks

    Jim
  19. Replies
    352
    Views
    25,447

    They are a pressure sensor that indicates vacuum....

    They are a pressure sensor that indicates vacuum. You cannot damage them in a vacuum. Because the resolution is half a percent full scale,they are not accurate enough for a evacuation. You will still...
  20. Replies
    352
    Views
    25,447

    Just tap the temperature icon with the plug in it...

    Just tap the temperature icon with the plug in it above the black bar and it will open the home screen. It opens automatically if it senses pressure probes in the wireless network. If there are no...
  21. Replies
    352
    Views
    25,447

    Kevin, We are working on both, for right now,...

    Kevin,

    We are working on both, for right now, if you tap the wireless icon in the center of the suction gauge, you can switch between the active sensor and see the saturation temperature. I am...
  22. Replies
    352
    Views
    25,447

    Just playing around with some ideas for the...

    Just playing around with some ideas for the iConnect, fixing a problem that some say does not exist, but none the less, there was mention of this idea in a earlier post. What are thoughts on a "mini...
  23. Replies
    352
    Views
    25,447

    Chuck, It depends on the system. If a...

    Chuck,

    It depends on the system.

    If a fixed metering device you are automatically adjusting target superheat as the load changes which can happen very quickly.

    Watching performance as the...
  24. Replies
    352
    Views
    25,447

    A full user input mode was always part of the...

    A full user input mode was always part of the design of the product. We wanted technicians to be able to use the app and students to be able to use the app for free and get big benefits from it. We...
  25. Replies
    352
    Views
    25,447

    Sure, but most batteries cannot handle...

    Sure, but most batteries cannot handle temperatures higher than that anyway.
  26. Replies
    352
    Views
    25,447

    These are the ones....

    These are the ones. http://data.energizer.com/PDFs/l91.pdf
  27. Replies
    352
    Views
    25,447

    The iConnect may cost more, but you get more, and...

    The iConnect may cost more, but you get more, and feature for feature there is no comparison. The iConnect is in a whole different class, it is a true measurement system.


    You carry the...
  28. Replies
    352
    Views
    25,447

    Very easy to add charge, attach the probe to the...

    Very easy to add charge, attach the probe to the thumb nut connector, attach hose to the open port, and charge through the schrader with a ball valve equipped hose. I moved the schrader to the side...
  29. Replies
    352
    Views
    25,447

    Well the First iConnects have shipped into...

    Well the First iConnects have shipped into distribution and are ready for order!

    We had outstanding feedback for the beta test group on this product, and I can confidently say after the...
  30. Replies
    352
    Views
    25,447

    They will ship on or before the 16th. The darn...

    They will ship on or before the 16th. The darn belt clips held everything up. Sorry for the delay, but I promise it will be worth the wait.
  31. Replies
    352
    Views
    25,447

    I will work with any voltage, just input 600 and...

    I will work with any voltage, just input 600 and the power factor and you are good to go. We made the selector so we could input typical power factors for 240 and 460 volt systems. Many techs do not...
  32. Replies
    352
    Views
    25,447

    Looking like the 10th. We are waiting on the belt...

    Looking like the 10th. We are waiting on the belt clips. I should have them by Friday. The holidays slowed the delivery down. We are doing everything we can to shorten delivery.

    Thanks,

    Jim
  33. Replies
    352
    Views
    25,447

    I will know more next week. With the holidays we...

    I will know more next week. With the holidays we had a little delay in delivery of the belt clips. That is all I am waiting for to have them ready to ship. TruTech is less than 40 minutes form our...
  34. Replies
    352
    Views
    25,447

    Still targeting the end of December. Things are...

    Still targeting the end of December. Things are right on track for an end of the month release.
  35. Replies
    352
    Views
    25,447

    Ricky, That is 100% correct, the iConnnect is...

    Ricky,
    That is 100% correct, the iConnnect is not a replacement for the iManifold. The two products have completely different use case scenarios. The iConnect was born from the iManifold after...
  36. Replies
    1,054
    Views
    97,295

    Yes, it is in the plans. We are only waiting for...

    Yes, it is in the plans. We are only waiting for Apple now as far as the release. There is a lot of new things. We will get on some of that next week. I have been out of town all week in the UK doing...
  37. They are in the release, they might not update at...

    They are in the release, they might not update at exactly the same time as the application. I am not sure.
  38. Imperial iManifold Application Updates

    Android will be out in a day or so and Apple in 3-7. We are submitted and waiting on them.

    We have been really busy again with the iManifold application and added some really cool updates to make...
  39. Replies
    352
    Views
    25,447

    It is in the Radar, and it will take a bit of...

    It is in the Radar, and it will take a bit of firmware effort to due so so it is not as easy of a process as a simple application update.
  40. Replies
    352
    Views
    25,447

    The iConnect will in most cases be about the same...

    The iConnect will in most cases be about the same cost as the iManifold if not a little more for an equivalent sensor package. When you go all wireless you have a radio in every sensor and two more...
  41. Replies
    352
    Views
    25,447

    We are working on that. I am not sure. I will...

    We are working on that. I am not sure. I will know more in the next few days. Working on a manometer, and vacuum gauge for the iManifold and iConnect at the moment.
  42. Replies
    352
    Views
    25,447

    Happy to say that we are getting really close to...

    Happy to say that we are getting really close to the release of the iConnect. Our goal is to start shipping to distribution in the middle of December provided nothing earth shattering happens. This...
  43. Replies
    11
    Views
    825

    I am not saying it won't eventually be true, just...

    I am not saying it won't eventually be true, just not true now. :cheers:
  44. Replies
    11
    Views
    825

    When you take a snapshot all of the measurement...

    When you take a snapshot all of the measurement data is gathered from the wired and wireless probes as well as the pressure sensors. When you send a Report, the snapshot is combined with the customer...
  45. Replies
    11
    Views
    825

    No, that is not correct, it is tech to tech...

    No, that is not correct, it is tech to tech within company or within a group. A lead tech can support his own technicians, a distributor customers, or a factory rep a technician in the field.
  46. Replies
    15
    Views
    1,708

    Actually, depending on the design and the...

    Actually, depending on the design and the surrounding ambient and the temperature of the pipe you are measuring it can make a huge difference. There have been several studies by several of the...
  47. Replies
    11
    Views
    825

    In case you are wondering what you can see on...

    In case you are wondering what you can see on Tech Connect, here is the low down.

    Tech Connect allows for full viewing of measurements, performance data, and remote troubleshooting as well as...
  48. Replies
    11
    Views
    825

    Imperial iManifold Tech Connect

    Here is the formal Imperial Tools Tech Connect Video.


    http://youtu.be/XVOVzP_555U
  49. Replies
    20
    Views
    1,856

    The probes are small and light enough they can...

    The probes are small and light enough they can hang by the hose. The hose is also too short to bend where it would easily attach with a magnet.

    The probes are actually made by Cooper Atkins.

    I...
  50. Actually it is a back calculation of airflow from...

    Actually it is a back calculation of airflow from coil performance based off temperature split. The airflow indicator shows if you have enough airflow to continue continue charging. It will be in the...