  1. Thread: NAE Query

    by phantomtech
    Replies
    12
    Views
    604

    You need to select all and then use the action...

    You need to select all and then use the action tab command.
  2. Replies
    9
    Views
    1,606

    Stromquest has replacement coupler for the...

    Stromquest has replacement coupler for the AP-VMA1420-0
  3. Replies
    9
    Views
    985

    The rearview camera mounted in the lisense plate...

    The rearview camera mounted in the lisense plate bracket gives a much greater view than you could get out the rearview mirror.
  4. Replies
    7
    Views
    1,087

    The SA bus (Sensor actuator bus) is for IOMs to...

    The SA bus (Sensor actuator bus) is for IOMs to expand the IO count of the NCE and addressable sensors like the tstat.
    The FC bus is for field controllers. On the NCE you have to order the NCE with...
  5. Replies
    1
    Views
    479

    I had this problem years ago on a different...

    I had this problem years ago on a different device. I added a 8ohm resister inline with the signal to load the circuit and it has worked ever since.
  6. Replies
    3
    Views
    590

    Install a supply and return air flow station and...

    Install a supply and return air flow station and calculate the outside air.
  7. Replies
    8
    Views
    566

    If these controllers are 11 years old you...

    If these controllers are 11 years old you probably need to upgrade the firmware in all off them. Chances are your HVACpro is a newer rev.
  8. Thread: VMA1620

    by phantomtech
    Replies
    2
    Views
    952

    There is no pressure dependent application....

    There is no pressure dependent application.
    However this is what I dowith the N2 1420 VMAs You can try this for the 1620 and see what happens.
    When the DP sensor is unreliable the VMA will operate...
  9. if you have smoke fire dampers they may be...

    if you have smoke fire dampers they may be closing to fast on power failure and tripping the hi static.
  10. Replies
    5
    Views
    728

    Renut the NCE and use the extended update.

    Renut the NCE and use the extended update.
  11. Replies
    20
    Views
    2,048

    Remove the old ADS from the network. Connect the...

    Remove the old ADS from the network. Connect the new ADS to the network and the NAEs will apper if all your settings are correct. The ADS does not assign the NAEs. The NAEs look for the site director...
  12. Replies
    8
    Views
    1,353

    If you want to prove flow and direction you can...

    If you want to prove flow and direction you can install an onicon flow meter.
    This will give direction of flow and gpm thru the chiller.
  13. Replies
    29
    Views
    2,430

    Ready Access Portal is free with the ADS/ADX...

    Ready Access Portal is free with the ADS/ADX software since Rev 4.1
  14. Replies
    29
    Views
    2,430

    Look into the ready access protal. it will do...

    Look into the ready access protal. it will do what you want.
    it is HTML and nio java needed.
  15. Replies
    2
    Views
    556

    Just installed one today with 8 wireless sensers...

    Just installed one today with 8 wireless sensers in an exihibit hall.
    Everything went as expected with no problems. After you add the wireless superviser and the points online you will need to reset...
  16. Replies
    16
    Views
    1,499

    Just a note. If you have user views on both...

    Just a note.

    If you have user views on both NAE's the user views on the non site director will be lost. Only the site director can have user views. Before you change the site director export the...
  17. Replies
    13
    Views
    1,162

    Open the DMO file in notepad and remove the *...

    Open the DMO file in notepad and remove the * from infront of the short name.
  18. Replies
    21
    Views
    2,092

    I had a customer that wanted to set the day and...

    I had a customer that wanted to set the day and time to change lead/lag on his pumps every week. He was only there once a week. This is the LCT process to do that. This process looks at the day of...
  19. Replies
    4
    Views
    525

    If you want to change the setpoint from the...

    If you want to change the setpoint from the supervisory controller, map in the Common Setpoint (PM6K1) from the .prn file, generated by HVAC Pro, as PMK36. In the controller configuration, change the...
  20. Set the baud rate on the NAE to 38.4

    Set the baud rate on the NAE to 38.4
  21. Replies
    4
    Views
    461

    Which vender device is it. Are you sure that this...

    Which vender device is it. Are you sure that this device supports direct mapped points without the use of cs objects.
  22. Replies
    19
    Views
    1,838

    Bad Idea. If you value your free time. I...

    Bad Idea.

    If you value your free time.

    I had a controls friend that thought he would automate everthing in his house.
    Every time he was out fishing or riding his motorcycle the wife would call...
  23. Replies
    27
    Views
    1,485

    I was told by a PC tech once that if the hard...

    I was told by a PC tech once that if the hard drive fails wrap in in a plastic bag and put in the freezer overnight. After you reinsatal it might run long enough to back up your data.
  24. Replies
    9
    Views
    7,548

    Check the baud rate on all devices.

    Check the baud rate on all devices.
  25. We use the Edgeport/1 usb to serial adapter from...

    We use the Edgeport/1 usb to serial adapter from Digi. It comes with a setup disk and will permanatly assign the com port you want.
    If I plugin the adater to any usb port on my laptop it...
  26. Replies
    6
    Views
    434

    You will need to add a network input in the cct...

    You will need to add a network input in the cct file.
    Map the point to the NAE.
    Create global data from the n2 point to the network input in the FEC.
    Now you can map the network input to the...
  27. Replies
    4
    Views
    3,004

    MetasysSysAgent can't be deleted. All you can do...

    MetasysSysAgent can't be deleted.
    All you can do is change the password to something ridiculous that can never be figured out.
  28. Replies
    7
    Views
    745

    A) Open the file you wish to download in CCT. B)...

    A) Open the file you wish to download in CCT.
    B) In Define Hardware, set the controller address to match the address on the DIP switch, and set the Instance Number (BACnet ID) to make it unique to...
  29. Replies
    7
    Views
    745

    Download again and select boot,main and...

    Download again and select boot,main and application
  30. Thread: PMI/NC350

    by phantomtech
    Replies
    7
    Views
    629

    Do you have spare DCM.s When thet fail it is...

    Do you have spare DCM.s
    When thet fail it is repair return only as they have not been manufactured for years. Can Your systems be down for days when this happens.
  31. Replies
    17
    Views
    1,108

    Yes Freddy it looks disorganized. But is as...

    Yes Freddy it looks disorganized. But is as intended.
    When the point is mapped it location is permanent as this becomes the full reference to the point. If you were able to reorder the all items...
  32. Replies
    17
    Views
    1,108

    I believe what he is doing now is editing the...

    I believe what he is doing now is editing the user views otherwise he would not be able to arrange the folders. I appears when the user views were created someone got lazy and added the controllers...
  33. Replies
    2
    Views
    427

    If you have the N2 asc's configured with hvacpro....

    If you have the N2 asc's configured with hvacpro. You will need to change the power-fail restart delays in all your ahu's to different values.
  34. Replies
    4
    Views
    484

    Metapage

    Metapage
  35. I have had this problem before and had to...

    I have had this problem before and had to reinstall the SCT on my laptop.
    When installing the SCT use must chose to install the hvacpro software to get the passthru function.
    You can also remote...
  36. Replies
    8
    Views
    1,161

    At 13% of the login process the NAE is checking...

    At 13% of the login process the NAE is checking your password.
    Make sure your password has not been changed.
  37. Replies
    10
    Views
    1,774

    You stated that this was a chiller in a box. The...

    You stated that this was a chiller in a box.
    The roof most likely is removable.
    Who's manufactured the box ie York,Chil-Pac?
  38. Replies
    8
    Views
    1,161

    Vista is not supported until Release 4.0 of MSEA...

    Vista is not supported until Release 4.0 of MSEA and for UI only.
    Unless your 2005 NAE has been ungraded you will have to XP.
  39. Replies
    6
    Views
    647

    The starter should have a PE switch on it now to...

    The starter should have a PE switch on it now to start the motor.
    Just replace it with a relay.
  40. Replies
    44
    Views
    2,370

    Still here and as busy as ever. I am pretty much...

    Still here and as busy as ever. I am pretty much virtual so I don't know any gossip. Haven't been it the office for a couple of months so I couldn't tell you about anyone else.
  41. Replies
    2
    Views
    444

    yorknet is the York dealer network it is not a...

    yorknet is the York dealer network it is not a com protocol.
  42. Replies
    9
    Views
    614

    Delete the point from the LCT process and save....

    Delete the point from the LCT process and save. Do a release all on the point.
    Command an override and than release it. If the point comes back at Priority 5 I would start looking for the point that...
  43. Replies
    9
    Views
    614

    Now that you have been specific I will tell what...

    Now that you have been specific I will tell what I saw one time.

    When the logic was created the programmer had selected the wrong priority
    and saved the logic. The logic had run and set the...
  44. Replies
    9
    Views
    614

    This is the Command priority list. 0...

    This is the Command priority list.

    0 (No Priority)
    1 (Manual Life Safety)
    2 (Auto Life Safety)
    3 (Application)
    4 (Application)
    5 (Critical Equipment)
    6 (Minimum...
  45. Replies
    5
    Views
    583

    In the last ten years I have seen this problem...

    In the last ten years I have seen this problem twice.
    One was a DX9100 and the other was an older model LCT.
    The capacitors on the AI's had dryed out causing all AI's to go unreliable.
    How old is...
  46. Replies
    6
    Views
    777

    As you know the N30 was the ABCS predecessor to...

    As you know the N30 was the ABCS predecessor to the FX system.
    In my area we can't service this system unless we receive a letter stating that they are unhappy with the service of the ABCS...
  47. Replies
    36
    Views
    2,413

    Actually JCI has a trade-in program form older...

    Actually JCI has a trade-in program form older model NAE's that will get you to 4.XX at no more cost than the actual software upgrade would be.
  48. Replies
    5
    Views
    692

    Without SCT you cannot upload and download the...

    Without SCT you cannot upload and download the NAE.
    What I have done in the past when I am experimenting is.
    Archive the NAE.
    Make my changes and test if this does not work you can go back to the...
  49. Thread: NAE 5520

    by phantomtech
    Replies
    5
    Views
    864

    This is the install document and point map.

    This is the install document and point map.
  50. Thread: NAE 5520

    by phantomtech
    Replies
    5
    Views
    864

    you need to add a Field bus for bacnet. hi-lite...

    you need to add a Field bus for bacnet.
    hi-lite the nae.
    select insert integration and select field bus.
    name is as field bus 2.
    you will need to select the hardware tab and change it to bus 2 to...