Search:

Type: Posts; User: Norriski Tech

Page 1 of 4 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    6
    Views
    216

    The PRN file is the answer!! You need a copy, or...

    The PRN file is the answer!! You need a copy, or need to create one with HVAC Pro. I run it on a Win 7 32 bit machine, and use a serial port replicator. Also a B&B 232 to 485 convertor it works well....
  2. Replies
    3
    Views
    140

    Automatrix to FX Jace

    Hello guys, my company is looking at a intergration from a automatrix system to a FX jace . I haven't made a site visit yet, I also have no automatrix background!! I see there is a PUP driver, and...
  3. Replies
    13
    Views
    640

    So got sick of waiting for my vendor. Which is...

    So got sick of waiting for my vendor. Which is one reason, I'm glad this site was developed. About a half a day, and I was signed up and on the Pro fx user community. I think once it really start's...
  4. Replies
    13
    Views
    640

    This site is a great resource!! I have asked,...

    This site is a great resource!! I have asked, many questions here. Another resource is always good!!
  5. Replies
    13
    Views
    640

    I haven't got the info from my vendor yet. But...

    I haven't got the info from my vendor yet. But Cagey, that looks like it might be it. Since the ABCS went to large vendors in our area, we have to due all tech support through them. It can be very...
  6. Replies
    13
    Views
    640

    JCI Dealer talk forum??

    Got a call from my vendor yesterday. Saying that the contractor talk forum was now available. Suppose to kind of be like Niagara Central. Was wondering if anybody using it?? He is suppose to be...
  7. I took a PCG/PCT class awhile back, and the loop...

    I took a PCG/PCT class awhile back, and the loop tuning portion. Started with 60 to 70% of the time the adaptive tuning doesn't work. My next thought was ,why would I use that?? I turn off the...
  8. Replies
    13
    Views
    394

    I just wrote a lead/Lag sequence for some boiler...

    I just wrote a lead/Lag sequence for some boiler pumps,and bld pressure fans. I could get it to you, for a look if you would like!!
  9. Replies
    13
    Views
    394

    Yes what reaper said!!

    Yes what reaper said!!
  10. Replies
    13
    Views
    362

    Yes what reaper said.

    Yes what reaper said.
  11. Replies
    11
    Views
    425

    Headed your way!!

    Headed your way!!
  12. Replies
    11
    Views
    425

    PM me with your email, and I will get it to you.

    PM me with your email, and I will get it to you.
  13. Replies
    11
    Views
    425

    I know JCI praise. Its hard to even say it!!

    I know JCI praise. Its hard to even say it!!
  14. Replies
    11
    Views
    425

    Yes I have taken a class from Vern. I also agree...

    Yes I have taken a class from Vern. I also agree with the fact that workbench is workbench. I work for a company who does both JCI, and Honeywell. I have done jobs with both, and JCI workbench does...
  15. Replies
    13
    Views
    1,892

    What is your busy time on the trunk having the...

    What is your busy time on the trunk having the problem?? How many normal polls?? On a big site I try get the busy time below 80%. I make different tuning policy's for the schedule, and fast polls,...
  16. Replies
    11
    Views
    425

    I have the actual FX training manual from a JCI...

    I have the actual FX training manual from a JCI class. The bad part is, it was scanned from the orginal manual, so the resolution sucks. I have it in PDF, if you interested I can email it to you....
  17. Replies
    13
    Views
    362

    Sorry fat fingered the enter key there!! So I...

    Sorry fat fingered the enter key there!! So I take it that your air-handler has heat?? As stated proxy the point in as 3113 instead of present value, that I had to learn the hard way. I'm in the...
  18. Replies
    13
    Views
    362

    I

    I
  19. I have 32 cypress wireless stats in operation....

    I have 32 cypress wireless stats in operation. Have had real good luck with them. Customer is looking at adding more in the future.
  20. Any suction pressure transducers?? Suction line...

    Any suction pressure transducers?? Suction line temp?? This could all help. R-22?? 410??
  21. Can you just use a PID those work well in kit...

    Can you just use a PID those work well in kit control. Or a reset??
  22. Replies
    1
    Views
    303

    In Kit control, the conversion folder very...

    In Kit control, the conversion folder very bottom. Numeric unit converter put that between your constant and the one shot. In the property sheet of the converter set the in facets to mins and the out...
  23. Replies
    28
    Views
    2,802

    I was a service guy, for most of my career. With...

    I was a service guy, for most of my career. With a control install and small programming background. For about three years, I have been doing nothing but controls, including all the programming,and...
  24. Replies
    23
    Views
    1,264

    Yes I was talking about after the Q&A what the...

    Yes I was talking about after the Q&A what the logic view is. It does look like a wire sheet?? When no Q&A is done maybe. I guess the discussion is more about the Q&A. I have watched guys who I would...
  25. Replies
    23
    Views
    1,264

    I took a class on PCT awhile back. The instructor...

    I took a class on PCT awhile back. The instructor was a ex JCI tech support guy for 20 years, and now works for our local distributor. When he started on PRAC tuning the first paragraph said PRAC...
Results 1 to 25 of 89