  1. Replies
    65
    Views
    1,672

    Yes I am that lucky. I have two accounts that I...

    Yes I am that lucky. I have two accounts that I split my time between. I know my customers very well. They spend a lot of money on their systems, so if I need to replace a sheave I replace it and...
  2. Replies
    65
    Views
    1,672

    Ok then it's even more simple. You aren't...

    Ok then it's even more simple. You aren't talking to the customer. Why not? If you had 3 out of 6 units crap out on one building who would give you the go ahead to replace them? There has to be...
  3. Replies
    65
    Views
    1,672

    Last I checked pictures can be emailed. You have...

    Last I checked pictures can be emailed. You have come up with a counter argument for everyone's suggestion, but I'll throw one more your way. You say to the customer (however many there may be and...
  4. Replies
    65
    Views
    1,672

    I like to show the customer. I place the sheave...

    I like to show the customer. I place the sheave gauge on the pulley and then take a picture of the light coming between the gauge and the pulley groove. Or, if it's a small one, I take the sheave...
  5. Replies
    4
    Views
    338

    Hoshizaki makes an automatic ice maker/bagger...

    Hoshizaki makes an automatic ice maker/bagger setup. Might be worth looking into. Around here most of the small stores depend on delivery from the regional ice house. The ice houses here provide...
  6. Replies
    43
    Views
    2,092

    If only add that it might help if you looked at...

    If only add that it might help if you looked at the compressor as a compressor and a vapor pump. Maybe this would help you to wrap your mind around a little easier.
  7. Replies
    43
    Views
    2,092

    ^^^^ Ding, Ding, Ding

    ^^^^ Ding, Ding, Ding
  8. Replies
    7
    Views
    376

    Yes that would be my recommendation. Analysis is...

    Yes that would be my recommendation. Analysis is relatively cheap. It's just like any other preventive maintenance tool. The more frequently you sample, the clearer the readings become.
  9. Replies
    7
    Views
    376

    I like to alternate oil analysis with oil changes...

    I like to alternate oil analysis with oil changes annually. Basically, I try to do oil change annually and then at the 6 month mark I do an oil analysis reading. Not just for acid, it keeps a...
  10. Replies
    34
    Views
    1,339

    If the condenser is dirty or condenser fan is out...

    If the condenser is dirty or condenser fan is out it will cause high discharge, in turn causing high suction. I would start there before I condemned the compressor.
  11. Replies
    30
    Views
    1,645

    That's very interesting. Who knew shaft seals...

    That's very interesting. Who knew shaft seals could lead to good conversation. I work mostly with Vilter 440/450 compressors. This is the actual language from their service manual. 471231
  12. Replies
    8
    Views
    549

    www.omega.com If you have time to order it...

    www.omega.com
    If you have time to order it they'll have what you need.
  13. Replies
    30
    Views
    1,645

    Not sure what the instructor was referring to in...

    Not sure what the instructor was referring to in this case. In order for the shaft seal to perform properly the bellows need to be constantly lubricated. There is a weep/drip hole in the bottom of...
  14. Replies
    30
    Views
    1,645

    100% agree with all the previous posts, but I...

    100% agree with all the previous posts, but I would also add that the compressor type you choose is going to be determined in large part by your system requirements and who engineers it. I have one...
  15. Replies
    1
    Views
    446

    Anyone heard of openings in the DFW area?

    Anyone heard of openings in the DFW area?
  16. Replies
    1
    Views
    446

    Industrial Refrigeration DFW

    Hello all. I am trying to relocate to the DFW area and need some help finding industrial refrigeration companies in the area. I have about four years of experience working on a variety of different...
  17. Replies
    20
    Views
    1,460

    Simple green in a Hudson sprayer. Spray the...

    Simple green in a Hudson sprayer. Spray the whole coil down with the simple green. Let it soak for a few minutes. Use water hose with nozzle to wash off dirt. If you have access to warm of hot...
  18. Replies
    10
    Views
    1,726

    I'll try that. Thanks medic.

    I'll try that. Thanks medic.
  19. Replies
    10
    Views
    1,726

    Run cap is new and I have checked it multiple...

    Run cap is new and I have checked it multiple times thinking the same thing. Still shows correct capacitance (35).
  20. Replies
    10
    Views
    1,726

    Compressor pulling high amps

    Alright guys,

    Looking for a little help on a problem unit I am dealing with. First call was to replace the dual cap due to condensing fan not running. Replaced the cap, but the compressor was...
  21. Replies
    10
    Views
    1,833

    Forklift....wheels up

    385481

    Have no idea how it happened, but my customer called asking for a crane and sent me this picture. In the end they were able to get it turned over with some other forklifts. Wish I could...
  22. Thread: Body cooler

    by tranger03
    Replies
    26
    Views
    1,792

    Suddenly the hotter than hell process plant in...

    Suddenly the hotter than hell process plant in working in doesn't seem so bad. If they ask you to check out a problem with the inside of the oven, I suggest turning that work down.
  23. Replies
    19
    Views
    1,362

    Sorry ga hvac my post was directed at the op not...

    Sorry ga hvac my post was directed at the op not to you. We must have posted at the same time. I also was trying to provoke the op to think where the moisture would have come from that they thought...
  24. Others have said it but it doesn't seem like they...

    Others have said it but it doesn't seem like they were heard. Before you do anything else you need to clear the sight glass and set the superheat for each txv, not just if it is "flowing" or not. ...
  25. Without knowing the amp draw on the motor it's...

    Without knowing the amp draw on the motor it's going to be hard to say what's wrong with your motor. My advise would be to triple check that all of your connections are torqued properly.