  1. Replies
    4
    Views
    888

    Another doozy is to make sure that you don't have...

    Another doozy is to make sure that you don't have Skype opening on computer startup...that's another one that runs on port 80.
  2. Replies
    40
    Views
    2,356

    100% Agreed. I've seen the exact same thing.

    100% Agreed. I've seen the exact same thing.
  3. Replies
    40
    Views
    2,356

    Ah, so now we understand each other. I guess I...

    Ah, so now we understand each other. I guess I don't know of many (maybe Trane) "canned" BACnet VAV-controllers. Could you name a few? All the "big" brands (that I've dealt with) are programmable...
  4. Replies
    40
    Views
    2,356

    I'm not talking about ticking the "network...

    I'm not talking about ticking the "network visible" box (ALC). What if a VAV-controller programmer decided NOT to attach an AV for damper position?

    From your point of view...so for EVERY...
  5. Replies
    40
    Views
    2,356

    Interesting. I thought one of the points of LON...

    Interesting. I thought one of the points of LON is to prevent this.



    I would like to know this also...I really need to brush up on my Lonworks stuff...
  6. Replies
    40
    Views
    2,356

    You're talking about my item #2. What if not all...

    You're talking about my item #2. What if not all important parameters are exposed (ie there is no "easy" way to directly expose setpoints using ALC's control programming)? And yes, I have went your...
  7. Replies
    40
    Views
    2,356

    I guess I don't. I was referring to davem's...

    I guess I don't. I was referring to davem's post.

    I was referring to the following situation (that I've ran into):

    I have two types of VAV boxes on the same MSTP loop, X and Y. I represent X,...
  8. Replies
    40
    Views
    2,356

    I guess then that leads to the local vs....

    I guess then that leads to the local vs. distributed control discussion. Without a local control program (inside the VAV controller for this example), what will happen to said box when the network...
  9. Replies
    40
    Views
    2,356

    Configure, ok. Program (code), no. I guess...

    Configure, ok. Program (code), no. I guess that's my main beef that will never go away with BACnet. As long as that software is included in the controls package (with stipulation to be able to...
  10. Replies
    40
    Views
    2,356

    Nothing. I install nothing (anymore). :o What...

    Nothing. I install nothing (anymore). :o

    What do you install? I've been out of the game for a little while...
  11. Replies
    12
    Views
    1,632

    Is your system dial-up, or ethernet? If...

    Is your system dial-up, or ethernet?

    If dialup, do you get the error message immediately after trying to connect (i.e., no hesitation in SuperVision at all)? If so, it might be a connection...
  12. Replies
    2
    Views
    727

    Exactly what I was looking for...thanks!

    Exactly what I was looking for...thanks!
  13. Replies
    2
    Views
    727

    WebCTRL/Logicbuilder for Education

    I thought ALC offered this (or something like this) for free. But I can't find the link. Does anyone know what I'm talking about?

    Thanks!
  14. Replies
    4
    Views
    492

    JKeep an eye out...some do auto-baud detect and...

    JKeep an eye out...some do auto-baud detect and others use dip switches. Just make sure they support the speed you're after...
  15. Replies
    13
    Views
    1,091

    EXTREMELY good information to know.

    EXTREMELY good information to know.
  16. Replies
    15
    Views
    2,866

    You're right... I still get the S6104, SE6104,...

    You're right...

    I still get the S6104, SE6104, and the SE6104a all mixed up. Thanks man.
  17. Replies
    15
    Views
    2,866

    I think the SE6104 is still access port...the...

    I think the SE6104 is still access port...the SE6104a is RNET...
  18. Replies
    42
    Views
    3,663

    That is a public link, so I don't think he's...

    That is a public link, so I don't think he's doing any wrong. They've posted the file on the dealer website also. Also, there isn't much you can do with the file unless you have logicbuilder...
  19. Replies
    42
    Views
    3,663

    Go to here:...

    Go to here: https://www.ctrlspecbuilder.com/sb/welcome.nsf

    Click on "Try It." Then click on 2 "Equipment." The questions and setup are similar to logicbuilder. The website spits out a spec, but...
  20. Replies
    12
    Views
    3,660

    If you're on the graphics page, first click on...

    If you're on the graphics page, first click on the microblock. Then you'll get a pop up to let you change the value on the microblock. Instead of changing the value, do an ALT-click on the value. ...
  21. Replies
    12
    Views
    3,660

    if that's the case, then use /trip instead of...

    if that's the case, then use /trip instead of /present_value for that parameter. An ALT-click in WebCTRL on that parameter will show you exactly need to do...
  22. Replies
    12
    Views
    3,660

    I'm thinking two hide show text expressions: ...

    I'm thinking two hide show text expressions:

    Text expression 1:
    ($m065/present_value$>=$m111/present_value$)

    Text expression 2:
    ($m065/present_value$>=$m067/present_value$)

    These equations...
  23. Replies
    8
    Views
    1,237

    If you're wanting to check/change the IP...

    If you're wanting to check/change the IP parameters, that can only be done if its an ExecB module.

    Check the ARCnet/Legacy dipswitch as well as the baudrate dipswitch.

    If ARCnet, APT = TTL. ...
  24. Replies
    15
    Views
    3,037

    If it was converted with InterOp, you'll need...

    If it was converted with InterOp, you'll need Eikon for SuperVision.

    In the webroot/<databasename>/programs folder I belive you'll find the .equipment files, but if you unzip them it will be .xml...
  25. Thread: CPC

    by control_8
    Replies
    1
    Views
    448

    I believe you will have to get the newest version...

    I believe you will have to get the newest version of Ultrasite in order to get it to work natively on Windows 7.

    If you can't get it, you can always do a Windows XP guest OS on VirtualBox and...