  1. Replies
    37
    Views
    1,452

    right on mr bill heated it up real good and sure...

    right on mr bill
    heated it up real good and sure as **** found the hole
    right above the pilot assembly that when cool you couldn't
    tell it was there
    easy fix now sold a new one!!!
    thanx for the...
  2. Replies
    37
    Views
    1,452

    got it on the mill test but don't have the tester...

    got it on the mill test but don't have the tester but.....
    if I were to test and find out the millivolts are low wouldn't changing the t-couple aliviate that?
  3. Replies
    37
    Views
    1,452

    yea replaced the valve with a slow opening ...

    yea replaced the valve with a slow opening
    Honeywell vr8200h and same condition happening
    still and it will happen at random times I. e. when they are asleep
    or out.
  4. Replies
    37
    Views
    1,452

    nat gas running pressure is8"in 3.3 manifold...

    nat gas running pressure is8"in
    3.3 manifold pressure running
  5. Replies
    37
    Views
    1,452

    exactly! along with the V A !

    exactly! along with the V A !
  6. Replies
    37
    Views
    1,452

    33yrs in the trade retired 2yrs ago been @ the...

    33yrs in the trade retired 2yrs ago
    been @ the block once or twice
    actually had this happen on a new install 20 yrs ago called the factory rep out(rheem) he couldn't find anything either so we...
  7. Replies
    37
    Views
    1,452

    10/4

    10/4
  8. Replies
    37
    Views
    1,452

    thatll be a day or two out but we will revisit ...

    thatll be a day or two out but we will revisit it here
    the heat is operable but wont be back there for awhile
  9. Replies
    37
    Views
    1,452

    ok so where do you/I go from here?

    ok so where do you/I go from here?
  10. Replies
    37
    Views
    1,452

    its a lennox 65k btuh upflow - does it it matter?

    its a lennox 65k btuh upflow - does it it matter?
  11. Replies
    37
    Views
    1,452

    went lookin for a downdraft scenario but that...

    went lookin for a downdraft scenario but that also looks good
    flue is solid and @ above peak draft is is good
  12. Replies
    37
    Views
    1,452

    yes everything in specs

    yes everything in specs
  13. Replies
    37
    Views
    1,452

    I am the end of the line!

    I am the end of the line!
  14. Replies
    37
    Views
    1,452

    yea I could see where that could happen its in a...

    yea I could see where that could happen
    its in a little closet (slotted doors) in a small 10x15 room;
    with an entrance door to the outside @ 10 ft from it
    or maybe a gust of air from closing the...
  15. Replies
    37
    Views
    1,452

    a little help please!

    got an older forced air system with a standing pilot that keeps going out.
    I changed the t-couple 2x
    cleaned pilot assembly&orifice & tube
    checked for crack in heat excher
    changed the gas valve&...
  16. Replies
    5
    Views
    1,157

    yea radio shack is where i tryed it they just...

    yea radio shack is where i tryed it they just didnt have the right size
    i think its 084 but havent measured it yet
    looks like that sunbeam kit might be the way to go
    its funny you mentioned...
  17. Replies
    5
    Views
    1,157

    pin extactor size?

    help me out guys--
    i need a pin extractor for the plugs on ignitors-
    refuse to cut the leads to make it work
    but i dont know what size or where to get one
    i know its not an .093 cause i tryed it...