Search:

Type: Posts; User: hvacman2213

Search: Search took 0.00 seconds.

  1. Replies
    3
    Views
    516

    chines drywall...

    someone i know lives in a house with chines drywall. I replaced two id coils in 3years. I go to his house today because its not cooling, I walk to back of house with my r22. Attach my gauges low 75...
  2. Thread: Aaon units

    by hvacman2213
    Replies
    18
    Views
    2,463

    i have 4 Aaon rooftops on top of a hotel in...

    i have 4 Aaon rooftops on top of a hotel in Naples. And two of witch have no charge i spent all day Friday looking for leaks. units are 2 year old i put 200psi of nitro and 1lb of 410 as a trace gas...
  3. Replies
    25
    Views
    2,323

    are you putting liquid in suction??? :gah:

    are you putting liquid in suction??? :gah:
  4. Replies
    2
    Views
    420

    (ending the day with ice in FL)

    One of are accounts calusa pines golf club. exclusive golf club 260 members 36 pro's in Naples FL. If you like golfing Google it, its a sweet place. I get there at 4:00 today to look at there kitchen...
  5. Replies
    3
    Views
    634

    are all plated exchangers set up this way?

    are all plated exchangers set up this way?
  6. Replies
    3
    Views
    634

    Plated heat exchanger

    Mcquay unit the line just past my txv go's into the top left of the exchanger and out the bottom right. My other circuit is vice verse going into that same heat exchanger. Now why not put lines...
  7. Replies
    14
    Views
    3,906

    337191 same roof.....

    337191 same roof.....
  8. Replies
    14
    Views
    3,906

    BEST ONE I EVER FOUND

    337111
  9. Replies
    28
    Views
    2,447

    Just like hearing different outlooks on it. Yes...

    Just like hearing different outlooks on it. Yes there are people in my shop that can explain it to me why dose it matter? is this website not a tool to jet help as well?
  10. Replies
    28
    Views
    2,447

    thank you alcomech big big help..

    thank you alcomech big big help..
  11. Replies
    28
    Views
    2,447

    thank you

    thank you
  12. Replies
    28
    Views
    2,447

    all i see is a smart unloader controller on...

    all i see is a smart unloader controller on carlyles website
  13. Replies
    28
    Views
    2,447

    336541

    336541
  14. Replies
    28
    Views
    2,447

    how do you set your unloaders?

    how do you set your unloaders?
  15. Replies
    28
    Views
    2,447

    we used a pump as well. now there was 2 valves on...

    we used a pump as well. now there was 2 valves on the top of the compressor by the low and high pressure ports. valves that can be adjusted with adjustable wrench is that some sort of equalizer?
  16. Replies
    28
    Views
    2,447

    sorry did not get back on the computer last...

    sorry did not get back on the computer last night. yes it was a replacement its a 40ton unit with 3 OD fan motors that i think load or unload off the discharg line. The comp was sent to us with no...
  17. Replies
    28
    Views
    2,447

    semi hermetic comp

    my first one tomorow tips or info would help big time thanks
  18. Replies
    2
    Views
    881

    Lol funny stuff...

    Lol funny stuff...
  19. Thread: Addicted!

    by hvacman2213
    Replies
    3
    Views
    886

    Thanks for the help

    Thanks for the help
  20. Replies
    2
    Views
    881

    What would you call this little guy?

    335031
  21. Replies
    72
    Views
    9,358

    This guy!!! come on man you know this stuff pull...

    This guy!!! come on man you know this stuff pull out that meter and continuity test that thing. you need to know things like this or your going to blow your self up.
  22. was that a china express!!!!

    was that a china express!!!!
  23. Replies
    19
    Views
    4,199

    now charge her for the duct job and add the price...

    now charge her for the duct job and add the price of a pull and clean..
  24. Thread: Addicted!

    by hvacman2213
    Replies
    3
    Views
    886

    Addicted!

    centrifugal chiller info would love everything you have.. I am new to the commercial side of things but feeling the energy of how people get addicted.
  25. Replies
    5
    Views
    1,870

    thanks guys for the support what all do i need to...

    thanks guys for the support what all do i need to have and do to become a pro member. Like i told you before i am only 22 im universally certified in epa if that helps.what do i need my post count to...
  26. Replies
    5
    Views
    1,870

    its a good week!!!

    started my new job Monday working commercial air conditioning for are service deportment of 36. I am 22 with a wife and a little girl I worked my butt of to get in such a well know company in sw...
  27. Thread: 422-D

    by hvacman2213
    Replies
    17
    Views
    2,117

    whats going to happen when he needs to defrost...

    whats going to happen when he needs to defrost lol if he even gets up to temp.
  28. Thread: 422-D

    by hvacman2213
    Replies
    17
    Views
    2,117

    422-D

    so i was at the supply house today and watched a guy pull in with a **** box truck. picked up a Rudd 2ton 13s unit and and a walk in cooling unit. think nothing of it and go on with my day. so i go...
  29. when i put flush in a unit in the past i put it...

    when i put flush in a unit in the past i put it in with intervals of 5-7sec 3-4 times followed by nitro?
  30. is it ever ok not to use flush or nitrogen on...

    is it ever ok not to use flush or nitrogen on line sets. i know contractors that would run a pump 1hr 2hrs depending on how long line set is. i know its not the right thing to do just know alot of...
  31. FLUSHING R22 LINE SETS WHEN SWITCHED TO 410

    is it necessary to flush line sets every time you switch 22 to 410. would like alot of feedback on this subject...
  32. Replies
    19
    Views
    2,772

    you could look at the frost pattern by running...

    you could look at the frost pattern by running the unit without your indoor blower to see if coil in frosting evenly od temp 77 what are you trying to get your inside temp down to? how olds the unit...
  33. its hard getting started at your age with no...

    its hard getting started at your age with no experience prob start off in residential for 1 to 2 years to get a grasp on things. Then another suggestion take the Nate test a lot of employers look for...
  34. Thread: Tool bags

    by hvacman2213
    Replies
    96
    Views
    17,845

    ace tools online clc bag is the way to go

    ace tools online clc bag is the way to go
  35. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  36. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  37. Replies
    29
    Views
    3,422

    i would shut my king valves and then put nitrogen...

    i would shut my king valves and then put nitrogen in my line that way you can see if its you condenser or not that would be my first step then test your lines individually it might be in the line...
  38. Replies
    4
    Views
    793

    thanks so much for your help. how do you get pro...

    thanks so much for your help. how do you get pro status?
  39. Replies
    4
    Views
    793

    Nate testing help

    i am new to hvac talk and wold like some help getting some good info on the Nate testing. would like some feedback on what to study thank you
  40. Replies
    11
    Views
    2,676

    nice

    nice
Results 1 to 40 of 40