    Thats what i did.I set min.35F' and max.55F' and...

    Thats what i did.I set min.35F' and max.55F' and temperature rise limits were 75F' if i remeber
  2. Replies
    14
    Views
    433

    I did run test.First stage was 37 F' when...

    I did run test.First stage was 37 F' when recommended is 40 and High fire was 48F' when recommended 42F',but i do not have many options to set up blower speed for heat,and l did not even check ESP...
  3. Replies
    14
    Views
    433

    Thank you Brown Tech. Now at least I know where...

    Thank you Brown Tech. Now at least I know where to started from.
  4. Replies
    14
    Views
    433

    I have problem with this particular furnace since...

    I have problem with this particular furnace since day one.system was design for oil heat only and in 60s converted to gas heat and AC,but nobody did load calculations.When I installed new Ac had a...
  5. Replies
    14
    Views
    433

    OK I will set it up again when get there.What...

    OK I will set it up again when get there.What parameters you are talking about?Max and Min of heat or time of test run or something else?
  6. Replies
    14
    Views
    433

    I set them manually.So You think there could be a...

    I set them manually.So You think there could be a problem?
  7. Replies
    14
    Views
    433

    Yes I did installed them in a summer and worked...

    Yes I did installed them in a summer and worked perfect .
  8. Replies
    14
    Views
    433

    Honeywell Prestige thermostat message

    Hello.
    For last couple of days one of My customer furnace (Westinghouse FG6TE Series) started working and strange message shows up on Prestige thermostat.
    It's unusual cause furnace has been...
  9. Thread: Blu-vac problem

    by ibenek
    Replies
    7
    Views
    918

    I did that.I remove battery for all day.,but when...

    I did that.I remove battery for all day.,but when plug battery back LTE turns on ,and pressing any one or couple of buttons together change nothing.
  10. Thread: Blu-vac problem

    by ibenek
    Replies
    7
    Views
    918

    Yes I did.,as matter of fact I calibrated this...

    Yes I did.,as matter of fact I calibrated this Micron gauge couple times before ,but yesterday i was so tired i just forget to turn it off after unfreezing process
  11. Thread: Blu-vac problem

    by ibenek
    Replies
    7
    Views
    918

    Blu-vac problem

    I have blu vac LTE for couple of years now and last night when went thru calibration I took it out from fridge and forgot about it.Today in the morning LTE was on, showing different words each time...
  12. Replies
    14
    Views
    1,206

    With blower door closed readings were the same...

    With blower door closed readings were the same next step would be TXV test.
  13. Replies
    14
    Views
    1,206

    Ambient temp. was about 70'F

    Ambient temp. was about 70'F
  14. Replies
    14
    Views
    1,206

    I check refrigerant load today in this system...

    I check refrigerant load today in this system with open blower door compartment with hope it's poor air flow cause problems but unfortunately it did not change anything.Still freezing up.There is...
  15. Replies
    14
    Views
    1,206

    I have similar problem and it's not been solved...

    I have similar problem and it's not been solved yet.I did change out 3 ton condenser and ADP "A" coil with TXV. Westinghouse 2 stage heat 80K BTU variable speed blower furnace.Freeze up inside and...
  16. Thread: Blu Vac

    by ibenek
    Replies
    31
    Views
    3,037

    Try this out ...

    Try this out
    http://www.monoprice.com/Search?keyword=foam
  17. Thread: Ak900

    by ibenek
    Replies
    10
    Views
    1,842

    Who told you I'm going to trade?i asked you if...

    Who told you I'm going to trade?i asked you if you can fix it that's all
  18. Thread: Ak900

    by ibenek
    Replies
    10
    Views
    1,842

    How old are those?Do you accept paypal?Do you...

    How old are those?Do you accept paypal?Do you have any pictures?
  19. Replies
    603
    Views
    93,150

    I already have SMAN 3 but why don't you fix AK...

    I already have SMAN 3 but why don't you fix AK 900 for me?
  20. Replies
    603
    Views
    93,150

    Maybe You're right, but just because I can't...

    Maybe You're right, but just because I can't speak English fluently doesn't mean I'm inferior customer, and money I'm paying are still green$
  21. Replies
    603
    Views
    93,150

    On a high side black+ white=3.9 V white +red= ...

    On a high side black+ white=3.9 V white +red= 0.3V
    on low side black+ white=0.3 V white+ red =3.9V
  22. Replies
    603
    Views
    93,150

    "communications may have failed here"?

    "communications may have failed here"?
  23. Replies
    603
    Views
    93,150

    I took everything possible apart,have not seen...

    I took everything possible apart,have not seen any abnormalities,unplug and cleaned transducers stations but it did not help.
  24. Replies
    603
    Views
    93,150

    Is there any different place than Digi-cool I...

    Is there any different place than Digi-cool I could buy this transducer?
  25. Replies
    603
    Views
    93,150

    So i'm the one with bad experience. Maybe cause...

    So i'm the one with bad experience. Maybe cause guarantee for AK 900 already expired long time ego?Maybe because it's July and They are as busy as Me?Maybe this or that.I did not say they bad folks...
  26. Replies
    603
    Views
    93,150

    Maybe it is lame from your point of view not...

    Maybe it is lame from your point of view not mine.Anyway if company stands behind their product don't you think they should try to contact me?or at least answer for my 6 or 7 e-mails?I do HVAC...
  27. Replies
    603
    Views
    93,150

    I did everything i could- took battery out hold ...

    I did everything i could- took battery out hold an "on" button for 10 seconds(Brenda) advice and nothing help.It's stuck .
  28. Replies
    603
    Views
    93,150

    high side shows 494PSIG and if a zero that its...

    high side shows 494PSIG and if a zero that its coming back to 494
  29. Replies
    603
    Views
    93,150

    Wait guys till AK 900 broke down like mine.Wrote...

    Wait guys till AK 900 broke down like mine.Wrote email week and a half ago,yes got respond from Brenda Lockhart to do some other test on Mine AK 900 and.............it's quiet form digi-cool...
  30. Thread: AK 900 fail

    by ibenek
    Replies
    8
    Views
    789

    Yes I check My spam folder frequently.

    Yes I check My spam folder frequently.
  31. Thread: AK 900 fail

    by ibenek
    Replies
    8
    Views
    789

    I wrote down e-mail to digi-cool 07/18 about this...

    I wrote down e-mail to digi-cool 07/18 about this problem.Next day got respond Brenda Lockhart and-nothing since.3 days with no respond,nothing.I need this tool everyday.Is this great consumer taking...
  32. Thread: AK 900 fail

    by ibenek
    Replies
    8
    Views
    789

    Thank you guys .Hope You are right about it.

    Thank you guys .Hope You are right about it.
  33. Replies
    9
    Views
    1,722

    sure it was working for ....a while.It's 3" above...

    sure it was working for ....a while.It's 3" above a level and long pipe run,so before water had a chance to flow down all that run PVC pipe must be filled ,and stay there until it's going to be more...
  34. Thread: AK 900 fail

    by ibenek
    Replies
    8
    Views
    789

    I did send an e-mail already its a weekend so...

    I did send an e-mail already its a weekend so waiting time.
  35. Replies
    9
    Views
    1,722

    Condensation problem?

    602431602441602451
  36. Thread: AK 900 fail

    by ibenek
    Replies
    8
    Views
    789

    AK 900 fail

    I had AK 900 for about 3 years but i've been using it most often lately and it broke down yesterday.High side shows 495 PSIG and it's not moving it all.I did zero it out but still no improvement.Took...
  37. Replies
    6
    Views
    1,562

    Thank You for help guys.Just to update I swap...

    Thank You for help guys.Just to update I swap Honeywell ST9120C with Armstrong R40403/003 and everything works fine.Furnace was Ducane MPGA050B3
  38. Replies
    6
    Views
    1,562

    It's ST9120C ST9120U is universal

    It's ST9120C ST9120U is universal
  39. Replies
    6
    Views
    1,562

    St9120 is the one I'm replacing with...

    St9120 is the one I'm replacing with Armstrong.Furnace is 15 or so years old Ducane
  40. Replies
    6
    Views
    1,562

    Honeywell ST9120C 2010 control board

    Heloo.
    Is there anybody knows what's the difference if any between Honeywell ST9120C 2010 control board and Armstrong Furnace Control Circuit Board R40403-003?
    Have to replace one Honeywell and...
  41. Thread: 240 V problem

    by ibenek
    Replies
    11
    Views
    1,381

    240 V problem

    I came across non function 2 ton Ac condenser and i was not able to solve problem couse strange voltage readings.
    When L1 was mesured to ground 118V L2 to ground 118 V L1 to L2 =reading 0V
    I now I...
  42. Replies
    6
    Views
    660

    I will try to defrost mode overnight and see what...

    I will try to defrost mode overnight and see what tomorrow brings.
  43. Replies
    6
    Views
    660

    There is no frost showing in the freezer.I...

    There is no frost showing in the freezer.I unplaged and pluged back fridge and it seems start cooling down but slowly.It took about 2 hours to cool down 5 degrees
  44. Replies
    6
    Views
    660

    Or maybe it's like zooning in HVAC?

    Or maybe it's like zooning in HVAC?
  45. Replies
    6
    Views
    660

    Thanks for respond.No not yet.I have not touch it...

    Thanks for respond.No not yet.I have not touch it .It's make me little wonder why one side is ok the other bad.I'm not able to find any drowing or schematichs for this fridge.Does it have 2 separete...
  46. Replies
    6
    Views
    660

    GE GSF25TG refrigerator

    Hello.
    I'm not sure by sending this post that i'm in a right place,if not i'm sorry.
    I'm in HVAC industry installer some tech work so have no experience on applianses it all,but want to give a...
  47. Replies
    16
    Views
    2,355

    BluVac disappoitment

    I have Blu Vac for about a year and lately it's nothing more than useless garbage.Problem started in May when I used once under pressure.
    First -oil- small indication appeared and even thought I...
  48. Replies
    0
    Views
    444

    local 73 Chicago

    I'm just a messenger.Came over on a Craig's list today.08/14
    Local #73 sheet metal installers. Full time position for reliable people with up to date Local #73 card. Please send resume.
    Reply to:...
  49. Replies
    6
    Views
    1,296

    Will they work with Acetylene or Oxy Ace. set?

    Will they work with Acetylene or Oxy Ace. set?
  50. Replies
    14
    Views
    4,917

    Spiral duct is tide up to concrete by electrical...

    Spiral duct is tide up to concrete by electrical wire.Also some of duct was lay down on two copper water lines.I did picture but quality is not acceptable.