  1. Replies
    9
    Views
    1,051

    Changed the heat kit because my technician saw...

    Changed the heat kit because my technician saw some discoloration on the heat strip, but I an still not convinced even if the strip touched ground this could happen
  2. Replies
    9
    Views
    1,051

    Burned flex duct lining

    We recently had service call where one 6" flex closest to the air handler on top of the metal supply plenum appears to have caught fire ( soot on ceiling around vent) and completely burned no signs...
  3. Replies
    13
    Views
    2,166

    Get and install equipment where it is easy to...

    Get and install equipment where it is easy to clean
  4. Replies
    39
    Views
    4,697

    Most HeatLoad software can be manipulated to say...

    Most HeatLoad software can be manipulated to say what he or she running the wants it to say..With 2 speed in Houston and variable speed blowers your humidity control will be greatly improved...And...
  5. what did the air handler look like???

    what did the air handler look like???
  6. Free for the first 100 people that buy the scale....

    Free for the first 100 people that buy the scale. Fieldpiece offers a discount for loyal users
  7. the field piece wireless has been 174 at...

    the field piece wireless has been 174 at johnstone.. have a cps on the other truck and liked it, fieldpiece was $20 more than cps, the wireless deal is nice to keep it dry in the rain
  8. Replies
    13
    Views
    2,187

    does te fan have autoswing feature on the blower...

    does te fan have autoswing feature on the blower flap, it may help if the vent flap is moving, also we find running 1/2 or 3/4 drain lline alswo keep condensate from collecting in the pan
  9. Replies
    29,819
    Views
    1,148,322

    Poll: hope you are keeping optimistic----try hard to...

    hope you are keeping optimistic----try hard to smile a coupla times a day-----
    life is a journey not a destination----qouted somebody smart
  10. Replies
    11
    Views
    801

    heat5 pump mini splits work great houston. A...

    heat5 pump mini splits work great houston. A heat pump or straight cool makes absolutely zero difference in the cooling mode. heat pump reverses thbe refrigertion process for the few cold days we...
  11. Replies
    47
    Views
    7,392

    if ya got two years out of it your better than me

    That is a 1988 or so model carrier and it probably had a stock 850 rpm 1/5 hp motor. The only one of this i can think of i put 2 fasco motors similar to the one ya got. the 3rd i went and got the oem...
  12. Replies
    11
    Views
    2,235

    please give out the recipe. the one for the...

    please give out the recipe. the one for the rasberry salsa
  13. Replies
    49
    Views
    3,006

    No!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!

    HVAC CO should not have to set up a generator to evacuate ur units then return to startup because u and ur contractor screwed up with the driveway. You cheap SOB the AC contractor should charge u...
  14. check it

    The bryant maybe a straight AC carriet HNA ht pump bryant ANA = sthriaght ac
  15. Replies
    138
    Views
    42,517

    be less vicious--------------put a panduit strap...

    be less vicious--------------put a panduit strap on their driveshaft of their truck---------drives em nuts:D
  16. Replies
    40
    Views
    13,071

    has anyone else seen in Rheem and Lennox furnace...

    has anyone else seen in Rheem and Lennox furnace a rust likeline develope in the heatexchanger as the burners inshot but it doesnt open, cvause flame disturbance or emit co into the airstream?
  17. Replies
    40
    Views
    13,071

    all furnaces since 91 had spark ign or HSI, I...

    all furnaces since 91 had spark ign or HSI, I have been a RUUD dealer the whole time either it is alot more the 10yrs old or the temp is a crack head-self proclaimed engineer jacka$$ and decided to...
  18. Replies
    52
    Views
    12,588

    dont knock my welds if ya glob the solder on it...

    dont knock my welds if ya glob the solder on it dont leak::cool:
  19. let the apprentices take the e-callouts senior...

    let the apprentices take the e-callouts senior techs would rather guide them over the phone than personally get dressed and go out at 3 am plus everyone must pay their dues apprentices included:cool:
  20. Replies
    339
    Views
    45,909

    houston 10 yrs in trade as service install...

    houston
    10 yrs in trade as service install retrofit
    res lt comm
    tx lic and NATE AC ser
  21. Replies
    47
    Views
    5,728

    the compressor has a high pressure relief that...

    the compressor has a high pressure relief that one blew up did they beat someone out of money?
  22. Replies
    104
    Views
    8,062

    my opinion on GPS mainly on extended lunch breaks...

    my opinion on GPS mainly on extended lunch breaks and personal errands is:
    A good service tech misses many breaks and lunches which most companies dock you an hour whether you take lunch or not,,...
  23. Thread: 9mm or not?

    by lil' randy
    Replies
    4,843
    Views
    321,450

    who from texas doesnt believe it is our god given...

    who from texas doesnt believe it is our god given right as a texan to carry and may the need arise use a concealed carry firearm. If you want to argue I will tell you tales of some neighborhoods in...
  24. Replies
    28
    Views
    10,072

    that looks like a job for a subcontrator. my...

    that looks like a job for a subcontrator. my spoiled change out guys would throw a fit..
    MY perception I bet the homeowner had a friend who is the maintenance guy at an apt complex and knew all...
  25. Replies
    13
    Views
    1,254

    for the first 6 months or so call a a/c co for...

    for the first 6 months or so call a a/c co for "advanced" diagnostic help then absorb the techs knowledge like a sponge also try RSES for some classes and last it is best to make the beginnner...
  26. Replies
    47
    Views
    5,728

    i would have to guess oxygen too but I have never...

    i would have to guess oxygen too but I have never seen it first hand though i sure would like to ka-booom
  27. Replies
    23
    Views
    4,718

    theives are our best job security:mad:

    theives are our best job security:mad:
  28. Replies
    26
    Views
    6,874

    they need a whole system, insulating the ductwork...

    they need a whole system, insulating the ductwork could probably pay for the whole thing in a year
  29. Replies
    22
    Views
    4,046

    2 yrs is not long enough for a unit that still...

    2 yrs is not long enough for a unit that still has 8 yrs of warranty left.

    Manufacturer theory a system only needs to last through the warranty period then sell um our latest and greatest
  30. does superseal seal leaks or cause problems?

    I used superseal today for the second time. It goes against what we are taught about adding things to a refrigerant system. It was one of those special circumstances but was recommended by the parts...
  31. i did not know that the carrier sta furnace is a...

    i did not know that the carrier sta furnace is a zero clearance furnace also i bet a five ton furnace does great with less that 1.5 ton r/a:p
  32. Replies
    5
    Views
    2,574

    where is the e-pan?:eek:

    where is the e-pan?:eek:
  33. Thread: Got filter?

    by lil' randy
    Replies
    3
    Views
    1,459

    expensive filter:)

    expensive filter:)
  34. Replies
    5
    Views
    1,711

    i dont like the spp6 firecracker but this is a...

    i dont like the spp6 firecracker but this is a good place for one plus it is only a 2 ton::cool:
  35. Replies
    28
    Views
    10,072

    does the dryer exhaust into the attic?:eek:

    does the dryer exhaust into the attic?:eek:
  36. Replies
    10
    Views
    2,578

    I bet you would get apphixiated in the attic

    I bet you would get apphixiated in the attic
  37. Replies
    30
    Views
    5,594

    Does chainsaw charlie have any brands that he...

    Does chainsaw charlie have any brands that he doesnt install, I have seen pics of bad Carrier installs, bad trane installs has any other dealers ever considered getting his dealership revoked or...
  38. Replies
    30
    Views
    5,594

    that is why i have a small 5/16 ratchet in my bag...

    that is why i have a small 5/16 ratchet in my bag ; 20 minutes to get the cover off. if the condensers looked that bad what did the furnaces look like?
  39. Replies
    31
    Views
    5,390

    i thought the air conditioner makes cold air

    i thought the air conditioner makes cold air
  40. Replies
    22
    Views
    4,547

    is the base of the unit sealed or does it pull...

    is the base of the unit sealed or does it pull from around the media filter?
  41. Replies
    19
    Views
    4,637

    luckily noone ever steals a janijunk

    luckily noone ever steals a janijunk
  42. Replies
    19
    Views
    5,581

    i change my filter once a month right,,, and it...

    i change my filter once a month right,,, and it was probably brand new when you got there
  43. Thread: High Head

    by lil' randy
    Replies
    7
    Views
    2,023

    did ya figure out a way to clean those coils?

    did ya figure out a way to clean those coils?
  44. Replies
    27
    Views
    7,515

    In se texas that is the air contractor/installers...

    In se texas that is the air contractor/installers fault as all the houser venting range, fart fan dryer is done by the ac contrator
  45. when I lived in phoenix almost everything was on...

    when I lived in phoenix almost everything was on the roof ie Goettl heat pump rtu package units , it gets so hot there why would anyone use split sysytems in the attic. What kind of jacka** would...
  46. Replies
    24
    Views
    3,057

    between salt water, coil bandits and...

    between salt water, coil bandits and manufacturers planned obsolesence we gotta love the job security
  47. Replies
    16
    Views
    7,131

    the dappler had a good price

    the dappler had a good price
  48. Thread: Bad dog.

    by lil' randy
    Replies
    33
    Views
    6,897

    trash is trash and dealing with it is part of the...

    trash is trash and dealing with it is part of the job. makes me glad that my wife keeps a clean house
  49. Replies
    17
    Views
    3,505

    how straight is the duct run? what size vent and...

    how straight is the duct run? what size vent and duct? booster fans pull air or heat from all other areas to get more to one but if the duct is collapsed or blocked then... still no air is it flex or...
  50. i think he means a oversized evaporator, not...

    i think he means a oversized evaporator, not condenser