  1. I just looked at average winter low temps for...

    I just looked at average winter low temps for your area...+40˚. You could probably rewire the defrost control to cycle off the compressor instead of the fan, and let it "air" defrost. :grin2:
  2. Just about every mfg but Rheem. I ran across an...

    Just about every mfg but Rheem. I ran across an internet-purchased brand (I'd never heard of) recently that energized in heat, but don't know of any other resi equipment brands with the atypical...
  3. Best way to accomplish that is convert the...

    Best way to accomplish that is convert the defrost control to a "demand" type. Not sure Goodman has something you could just swap out with. The higher SEER units may come with demand controls that...
  4. Replies
    26
    Views
    1,051

    Low suction and low/non-existent superheat is...

    Low suction and low/non-existent superheat is airflow related. Not enough heat available to boil off the refrigerant. If it's intermittent, I'd guess a funky blower motor control. That or something...
  5. Replies
    24
    Views
    839

    Can't tell for sure, from all your posted info,...

    Can't tell for sure, from all your posted info, but a low to normal superheat, with the 50 psi suction pressure, is symptomatic of low airflow, and would suggest the TXV is attempting to do it's...
  6. Replies
    24
    Views
    839

    Why 1940 cfm for a 3 ton condenser? and how?...

    Why 1940 cfm for a 3 ton condenser? and how? :confused:

    I'm thinking erratic airflow rather than TXV problems.
  7. Replies
    7
    Views
    362

    Go here.. http://www.achrnews.com/# ...and do a...

    Go here.. http://www.achrnews.com/# ...and do a search for "low airflow".
  8. Replies
    20
    Views
    673

    The "normal" suction pressure for the ID/OD temps...

    The "normal" suction pressure for the ID/OD temps would probably be around 80 psi. You're at 60 (35˚ saturated)...once the sun goes down and the temps drop, so will the suction pressure. It's...
  9. Replies
    53
    Views
    1,779

    If the motor is running, there must be some...

    If the motor is running, there must be some voltage, on one of the motor leads, coming from some where, whether or not there's a "call" for fan.

    Use a clamp-amp meter to determine which lead(s) is...
  10. Replies
    14
    Views
    659

    I always forget about that little detail. :oops:

    I always forget about that little detail. :oops:
  11. Replies
    14
    Views
    659

    The tube you're referring to is the equalizer...

    The tube you're referring to is the equalizer line for the TXV, providing the necessary evaporator pressure to the valve, for it to work as designed. Since the system does well in cool cycle, there...
  12. Replies
    11
    Views
    516

    Thanks for the correction.

    Thanks for the correction.
  13. Replies
    11
    Views
    516

    Once the MIC motors came into play, I found...

    Once the MIC motors came into play, I found sleeve bearings to be the weak link, and began buying ball bearing motors.

    Half, and some, third horse universals are oftentimes too long for replacing...
  14. Thread: Goodman

    by Saturatedpsi
    Replies
    8
    Views
    423

    Those older Goodman "sequencer" type blower...

    Those older Goodman "sequencer" type blower controls are notorious for intermittent failures to "close" on a stat call. Quite likely the cause of the occasional freeze ups.
  15. Replies
    9
    Views
    329

    Bard also makes them...if you should need an...

    Bard also makes them...if you should need an option.

    http://www.bardhvac.com/digcat/S3364_TechDoc_CD/TechDoc-PDF/2100-468.pdf
  16. Replies
    14
    Views
    892

    Compressor manufacturers tend to specify...

    Compressor manufacturers tend to specify "compressor" superheat values, while equipment manufacturers usually specify "service valve" superheat values. And there's usually not a big difference...
  17. Replies
    29
    Views
    1,067

    A problem with the TXV or RV won't generate those...

    A problem with the TXV or RV won't generate those pressures, with a "normal" refrigerant charge. Recover refrigerant until the system will run without tripping HP limit, then try to do some analysis.
  18. The condensing temp is about equal to ambient....

    The condensing temp is about equal to ambient. Normal charge with a TXV issue would have higher head pressure than what you measured.

    10 year old unit, probably has a leaking coil. Add more freon...
  19. Replies
    22
    Views
    949

    It's quite possible, the new filter/dryer was...

    It's quite possible, the new filter/dryer was included to remind you to remove and replace the OEM/existing dryer.
  20. Replies
    39
    Views
    2,211

    Mufflers are always (all I ever saw) in the hot...

    Mufflers are always (all I ever saw) in the hot gas line at the compressor.

    The pressures, cool liquid/suction lines and "frosting" points suggest a liquid restriction and too much charge. Of...
  21. Thread: heat pump

    by Saturatedpsi
    Replies
    16
    Views
    744

    The thing is, I wasn't trying to be a...

    The thing is, I wasn't trying to be a smarta$$...if the pressure goes high and the compressor starts by-passing, what's to diagnose? I just assumed he wasn't watching (or measuring) the pressure on...
  22. Thread: heat pump

    by Saturatedpsi
    Replies
    16
    Views
    744

    If you measure the head pressure, the answer to...

    If you measure the head pressure, the answer to your question will likely be obvious.
  23. Replies
    7
    Views
    330

    OD + 50˚ SCT isn't normal for anything...

    OD + 50˚ SCT isn't normal for anything residential to my knowledge. OD + 20˚ is about normal for 13 SEER stuff.
  24. Replies
    9
    Views
    470

    Just out of curiosity, what were the codes?

    Just out of curiosity, what were the codes?
  25. Replies
    17
    Views
    1,265

    Where does "beginner" status begin and DIY status...

    Where does "beginner" status begin and DIY status end?