  1. Thread: Trainer

    by Matt Agee
    Replies
    3
    Views
    266

    Trainer

    These are some refrigeration trainers we are building at school. BCTC in Lexington, Kentucky. They have a high pressure switch, a low pressure switch, a TXV, a filter dryer, an sight glass, and a...
  2. Replies
    22
    Views
    934

    Put the Emerson and the Sporlan in series...

    Put the Emerson and the Sporlan in series together and then you'll catch the solids and the moisture too.:grin2:
  3. Replies
    19
    Views
    1,457

    I have a new project now ! Get some silicone...

    I have a new project now ! Get some silicone insulated wire and make some of those custom leads ! :)
  4. Replies
    62
    Views
    11,415

    Flexibility.

    Flexibility.
  5. Replies
    1
    Views
    314

    Service Manual Download ?

    I was on the section on here where you can download and print service manuals for ice machines the other day and I can't seem to find it now. Can anyone point me in the right direction ? Thanks.
  6. Replies
    62
    Views
    11,415

    Appion has great customer support as well. The...

    Appion has great customer support as well. The plunger on my core removal tool wasn't gripping the shraeder as it should. I called them and they immediately sent me a new one that worked great. No...
  7. Thread: Molex tool

    by Matt Agee
    Replies
    13
    Views
    1,131

    Radio Shack has those tools for a round $8.

    Radio Shack has those tools for a round $8.
  8. Replies
    6
    Views
    807

    Thanks, I'll check into the 375. I already have...

    Thanks, I'll check into the 375. I already have the 54II thermometer. I was hoping I could just have one tool that does it all so I didn't have to take up as much space in a small "go to" bag like...
  9. Replies
    6
    Views
    807

    Fluke Clamp Meter

    Does anyone know if fluke makes a clamp meter that measures both in-rush current as well as temperature ?
  10. Replies
    16
    Views
    2,220

    5 PSI acetylene and 7 PSI oxygen Is this with...

    5 PSI acetylene and 7 PSI oxygen
    Is this with the knob open or closed ?
  11. Replies
    26
    Views
    1,801

    Thanks guys !

    Thanks guys !
  12. Replies
    26
    Views
    1,801

    Nitrogen tank pressure ?

    How many PSI should a newly filled 40 cubic foot nitrogen tank have on it ? I just exchanged one and it has 2000psi. is that about right ? Thanks in advance.
  13. Replies
    33
    Views
    1,307

    I should be out that way this weekend. I'll try...

    I should be out that way this weekend. I'll try to get some pressures, SH SC then.
  14. Replies
    20
    Views
    1,263

    5 = CAN = COMMON 2 = SHE = START 1 = RUN = RUN...

    5 = CAN = COMMON
    2 = SHE = START
    1 = RUN = RUN
    A GOOD WAY TO REMEMBER :grin2:
  15. Replies
    33
    Views
    1,307

    It's not short cycling. It runs about the normal...

    It's not short cycling. It runs about the normal amount of time to satisfy the thermostat. The only complaint is the electric bill. At this point I'm not sure if the problem is the unit or not. ...
  16. Replies
    33
    Views
    1,307

    Haven't checked any pressures or SH/SC but it is...

    Haven't checked any pressures or SH/SC but it is cooling/heating ok. Just the electricity usage issue on the bill is the only complaint.
  17. Replies
    33
    Views
    1,307

    Both

    Both
  18. Replies
    59
    Views
    6,114

    http://http://youtu.be/5JLveeyYPEE Hilmor makes...

    http://http://youtu.be/5JLveeyYPEE
    Hilmor makes this one.
  19. Replies
    33
    Views
    1,307

    Their complaint is that the electric bill is...

    Their complaint is that the electric bill is getting out of hand and I am trying to identify the cause.
  20. Replies
    33
    Views
    1,307

    What meter would be good to capture in-rush...

    What meter would be good to capture in-rush current ? I know the Fieldpiece SC56 and the Amprobe ACD-51 NAV both have in-rush measuring capability. I just wondered if anyone has used any and which...
  21. Replies
    33
    Views
    1,307

    Thanks guys ! I guess I'm within tolerance then...

    Thanks guys ! I guess I'm within tolerance then at 30.
  22. Replies
    33
    Views
    1,307

    Condensing unit In-rush AMP. draw

    I have a Lennox M/N 10HPB18-14P SERIAL# 5805F24778. R22

    COMPRESSOR RLA 8.6
    LRA 49
    FAN MOTOR FLA 1.1
    FAN MOTOR 1/6 HP

    This unit is drawing around 30 amps. on startup and around 5 after it...
  23. Replies
    5
    Views
    502

    Thanks for the reply. :)

    Thanks for the reply. :)
  24. Thread: Resistors

    by Matt Agee
    Replies
    10
    Views
    686

    Ebay has these - 2W 1W 1/2W Resistor Assortment...

    Ebay has these - 2W 1W 1/2W Resistor Assortment Kit 2 Watts 1 Watt - $18.33 including shipping.
  25. Replies
    5
    Views
    502

    Replacing lost compressor oil ?

    I'm a first year HVAC student and I was wondering something. When refrigerant is recovered from a system, a small amount
    oil is taken out each time a recovery is done, right ? So, that being...
Results 1 to 25 of 57