Search:

Type: Posts; User: Dchappa21

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Thanks for the video.. took me right back to my...

    Thanks for the video.. took me right back to my green years. I can remember watching the whole series on vhs when I first started.
  2. Thread: Clogpopper ?

    by Dchappa21
    Replies
    7
    Views
    503

    This thing looks like a home made tool that...

    This thing looks like a home made tool that someone came up with when they couldn't find there shop vac. Right up there with the mighty pump.
  3. Replies
    33
    Views
    2,942

    Had my tech pac since Christmas. No problems...

    Had my tech pac since Christmas. No problems yet... I did have to send my LC in 3 times over 5 years.... which doesn't seem to bad to me... hopefully the tech pac holds up the same...
  4. Replies
    7
    Views
    524

    X 4... except I don't need the little carrying...

    X 4... except I don't need the little carrying chase. I would just through a couple of pressure probes in the veto.
  5. Replies
    65
    Views
    2,089

    Might want to install a high pressure switch on...

    Might want to install a high pressure switch on that biatch.
  6. Replies
    33
    Views
    1,435

    I'll have to remember that one... some york and...

    I'll have to remember that one... some york and carrier units use torx screws. T25? Maybe.
  7. Replies
    33
    Views
    1,435

    Has anyone had to use the damaged core remover...

    Has anyone had to use the damaged core remover side?? Does it actually work?
    I agree I have no use for a square bit on my multi screwdriver...
    Think I might prefer a torque bit for locking...
  8. Replies
    18
    Views
    622

    Use nylog to seal it... your talking about the...

    Use nylog to seal it... your talking about the bottom adjustment cap, right?
  9. Replies
    3
    Views
    330

    Yep, run the pump while un sweating and just...

    Yep, run the pump while un sweating and just barley crack the valve on your pump and gauges.
  10. I think im wrong. I think it needs to have more...

    I think im wrong. I think it needs to have more than 50 pounds in it for them to care.
  11. The epa would disagree

    The epa would disagree
  12. Replies
    4
    Views
    345

    Looks like I can see some of the equipment I...

    Looks like I can see some of the equipment I added first. Maybe it hasn't updated all my info yet?
  13. Replies
    4
    Views
    345

    Been using this and like it but I can't view my...

    Been using this and like it but I can't view my equipment sense you recoded it today... still have the locations but can't see the units...
  14. Replies
    10
    Views
    512

    Time to call for service

    Time to call for service
  15. Seen the label on 134a showing that too. Even...

    Seen the label on 134a showing that too. Even though it's not a blend.
  16. Thread: Forane 22

    by Dchappa21
    Replies
    3
    Views
    215

    My favorite is mexichem.... Have only seen it in...

    My favorite is mexichem.... Have only seen it in r404a though.

    I've seen plenty of forane it's been around along time.
  17. Replies
    10
    Views
    633

    Thanks ice.. That will come in handy. I like the...

    Thanks ice.. That will come in handy. I like the MCC and a couple different btu specs.
  18. Dude install a low pressure control. The valve is...

    Dude install a low pressure control. The valve is fine but you may want to change the oil if you really have moisture in the system. Or just keep changing the drier until your glass stays green........
  19. Replies
    12
    Views
    471

    +2 Sent from my SM-G900V using Tapatalk

    +2

    Sent from my SM-G900V using Tapatalk
  20. Got my today too. Will try them this week. Thanks...

    Got my today too. Will try them this week. Thanks for the info


    Sent from my SM-G900V using Tapatalk
  21. Replies
    65
    Views
    4,830

    I'm happy I got my magnet.! But I got a perfectly...

    I'm happy I got my magnet.! But I got a perfectly working sc56....
    It's pretty nice to have manufactures actually listen to what techs are asking for.

    Sent from my SM-G900V using Tapatalk
  22. Thread: pump down

    by Dchappa21
    Replies
    20
    Views
    1,113

    Most low temp pumps also don't like starting with...

    Most low temp pumps also don't like starting with a high suction pressure.


    Sent from my SM-G900V using Tapatalk
  23. Thread: pump down

    by Dchappa21
    Replies
    20
    Views
    1,113

    Main reasons would be to prevent liquid migration...

    Main reasons would be to prevent liquid migration and prevent flood back on start.

    Sent from my SM-G900V using Tapatalk
  24. Ok, thanks email sent.

    Ok, thanks email sent.
  25. Hey Chris I emailed appion a while ago about my...

    Hey Chris I emailed appion a while ago about my plungers not grabbing the cores on live systems and never got a response.... Should I just keep emailing? Or try calling???

    I bought 2 of these back...