  1. Replies
    1
    Views
    1,135

    Did you pull the drain body and check for...

    Did you pull the drain body and check for something jammed against the flapper?
  2. Replies
    2
    Views
    1,024

    P codes are code errors. If they keep coming back...

    P codes are code errors. If they keep coming back and your probes are all good, the board may not be keeping it's configuration in its' memory correctly.
  3. Replies
    5
    Views
    1,269

    No, the part # changed.....Your local Hobart will...

    No, the part # changed.....Your local Hobart will hook you up.
  4. Replies
    5
    Views
    1,269

    It is a common issue with several solutions. The...

    It is a common issue with several solutions. The first is to make sure the handle stops in the 3 o clock position when the bowl yoke is in the up position. If that doesn't solve the issue a weight on...
  5. Replies
    21
    Views
    2,520

    controling overtime costs

    Attention hourly employees, business owners and managers; I am working towards a bachelorís degree and writing a term paper on the topic of reducing employee overtime while maintaining quality...
  6. Try telling a customer that the reason their vat...

    Try telling a customer that the reason their vat welds failed on their UltraFryer is because they drained the grease out of it right after shutting it down and the cool air hitting the hot tank...
  7. Replies
    615
    Views
    112,561

    So how many of us have written up 'repaired...

    So how many of us have written up 'repaired broken electrical connection' to cover for the employee that did not make sure the unit was plugged in before calling the service company????? I write that...
  8. Thread: screwdrivers

    by chrldwlf
    Replies
    71
    Views
    13,383

    I use the Husky clear handled 6 in 1's the HoDePo...

    I use the Husky clear handled 6 in 1's the HoDePo sells. I buy them in pairs and they last about 9 months before I wear out the 5/16ths bore. The nice thing about having a matching set is you can...
  9. Thread: Kobalt Tools

    by chrldwlf
    Replies
    32
    Views
    18,528

    Buy the Klein linesman pliers now or buy the...

    Buy the Klein linesman pliers now or buy the Kobalt pliers now and the Klein pliers later. I have put many a whipping on my Klein pliers, even using them as a hammer when i am too lazy to go get a...
  10. No door gaskets on that unit. There is a torsion...

    No door gaskets on that unit. There is a torsion bar assembly which helps close the door but that will have no effect on your leak. Check the wash arms for a split seam on the side, also make sure...
  11. Replies
    5
    Views
    1,739

    Vulcan does have a 10 year pro rated tank...

    Vulcan does have a 10 year pro rated tank warranty....But the work has to be done by authorized Vulcan repair company....And it probably is not worth the hassle unless it is on tank in a bank of...
  12. Replies
    3
    Views
    840

    Again, I would 'soak' the control board in a bag...

    Again, I would 'soak' the control board in a bag of dry rice after cleaning the various ribbon cable plugs with contact cleaner.....If all else fails you may have to deal with the local service...
  13. Replies
    1
    Views
    607

    Depends on what you want to spend....Probably...

    Depends on what you want to spend....Probably cost about as much as a used KIA Rio (Sorry, no pricing) to repair the oven. Compared to a loaded new F150 to replace it with a new oven. The...
  14. Replies
    3
    Views
    840

    Could be any number of things, all I can offer is...

    Could be any number of things, all I can offer is irresponsible speculation at this point.....like it sounds like a bad control board...however.....
    What does this thing do after it flashes '17'?...
  15. Replies
    10
    Views
    2,136

    My only advice to this guy would have been to...

    My only advice to this guy would have been to call a pro for (what seemed to me) obvious reasons. Nothing can turn a restaurant into a smoldering pile like a rigged fryer.... And I agree with Kim and...
  16. Do yourself a favor and replace the solenoid...

    Do yourself a favor and replace the solenoid valve. they usually decide to let go when you are not paying attention and you can end up with one heck of a flood. Additionally, your homeowners...
  17. Replies
    12
    Views
    1,989

    I got $20 that says tipsrfine not only KNOWS the...

    I got $20 that says tipsrfine not only KNOWS the answer but cares enough to inform you of the repercussions of 'tricking' a safety device.....If you are smart enough to alter a safety device then you...
  18. Replies
    14
    Views
    2,659

    So we are loosing pressure, rinse arms are not...

    So we are loosing pressure, rinse arms are not spinning but the unit fills up within a semi reasonable amount of time.....Have your chemicals eaten a hole in one of the inner rinse pipes? This would...
  19. Replies
    3
    Views
    2,527

    Is the booster heater working? The unit will not...

    Is the booster heater working? The unit will not do a final fill until the booster reaches 180 degrees or 8 minutes has elapsed. You can bypass this by opening the control drawer, using a female...
  20. But you kept the dollars in Michigan, Lord knows...

    But you kept the dollars in Michigan, Lord knows we need them.....
  21. Replies
    8
    Views
    2,120

    I know nothing about HVAC and I could do better...

    I know nothing about HVAC and I could do better then that....
  22. Our company is going to the Ford Transit, which...

    Our company is going to the Ford Transit, which is imported from India and can carry everything but your dignity....Personally, both my wife and I made our auto purchases based on both being an...
  23. Replies
    5
    Views
    2,470

    lefty loosy, righty tighty.....easy money:grin2:

    lefty loosy, righty tighty.....easy money:grin2:
  24. Replies
    5
    Views
    2,470

    Sigh.....That board will run both the LXi and the...

    Sigh.....That board will run both the LXi and the AM select and has to be programmed correctly....I will see if I have programming instructions tomorrow
  25. Replies
    5
    Views
    2,470

    did you program the board for AM select per the...

    did you program the board for AM select per the instructions included in the board?
  26. Thread: On call pay

    by chrldwlf
    Replies
    82
    Views
    19,604

    Four hours OT pay for the week I am on call, 2...

    Four hours OT pay for the week I am on call, 2 hours for the rest of the on call team I am in charge of. Time and a half portal to portal except Sunday when it is double time portal to portal.
  27. Replies
    7
    Views
    3,192

    ml # would be helpful....

    ml # would be helpful....
  28. Replies
    7
    Views
    3,192

    Have to narrow down what A 200 schematic you...

    Have to narrow down what A 200 schematic you need....that thing has been in production since the dawn of time......
  29. Replies
    7
    Views
    3,414

    DE is for the newer LX/LXi models with the...

    DE is for the newer LX/LXi models with the chemical sensing board. SD/PF is a rinse time option, SD is standard rinse time, PF runs rinse water until top rear probe is satisfied.
  30. Replies
    7
    Views
    3,414

    press & hold the key which is hidden behind the...

    press & hold the key which is hidden behind the model (LX30) and the wash key on the control panel.Slide open the control board drawer. You should be able to toggle through the set points pushing the...
  31. It looks like can be switched over simply enough...

    It looks like can be switched over simply enough by swapping the orifices and pressure regulator. Vulcan may not be willing to help much though, according to them, only authorized service companies...
  32. Replies
    4
    Views
    1,342

    approx. 14,800 ohms @ 160 degrees. 100,000 ohms @...

    approx. 14,800 ohms @ 160 degrees. 100,000 ohms @ room temp (77 degrees)
  33. Replies
    12
    Views
    3,363

    What Marter says....

    What Marter says....
  34. Replies
    5
    Views
    2,154

    Electronic ignition or standing pilot? Vulcan...

    Electronic ignition or standing pilot? Vulcan made both types, I am assuming it is electronic ignition with the mercury burner safety valves. My 1st guess is pilot burner clogged with dust, there is...
  35. Replies
    4
    Views
    1,544

    Lemmee guess, Dunkin Donuts.....There is a rack...

    Lemmee guess, Dunkin Donuts.....There is a rack location reed switch (N.C.) attached to the roof of the oven at 9 o'clock and a magnet attached to the pulley. Check to see if it is stuck closed. Also...
  36. Cal a licensed HVAC company to evacuate the unit,...

    Cal a licensed HVAC company to evacuate the unit, remove the door and take the whole mess to the scrap yard where it belongs. A couple hundred clams will get you a basic chest freezer that will run...
  37. Replies
    4
    Views
    2,634

    But I was able to use the download.....THANX!

    But I was able to use the download.....THANX!
  38. Replies
    26
    Views
    3,902

    I went from meat dept. manager to food service...

    I went from meat dept. manager to food service repair. Currently I am working towards my Bachelors degree in business administration. I want to have minions do my bidding rather then being a minion...
  39. Thread: Work Vehicle

    by chrldwlf
    Replies
    19
    Views
    1,666

    My van currently suffers from the 'long winter...

    My van currently suffers from the 'long winter blues'.....It has been way to cold to do much housekeeping other then put stock away....However, the weather is starting to get warmer so the excuses...
  40. Replies
    4
    Views
    1,514

    What is your gas pressure? Are these flame...

    What is your gas pressure? Are these flame sensors actually flame switches? I have witnessed these switches fail to close when either the pilot flame is either too weak to properly heat the lead or...
  41. Replies
    28
    Views
    6,293

    I do not understand how recommending a part that...

    I do not understand how recommending a part that has been in the same hot oil, been under the same stresses, and had the same indifferent treatment by who knows how many minimal wage fry cooks be...
  42. Replies
    28
    Views
    6,293

    So when I am faced with the classic failed fryer...

    So when I am faced with the classic failed fryer hi limit scenario, I will give the customer the option of replacing both T-stat and hi limit at the same time. If fact I strongly recommend doing so....
  43. Replies
    11
    Views
    1,462

    Microwaves can be lethal to work on if you start...

    Microwaves can be lethal to work on if you start poking around on the high voltage side of the transformer. Google microwave repair deaths for more information on what not to do.
  44. Replies
    6
    Views
    2,638

    Those are the normal wash arms. Check them for...

    Those are the normal wash arms. Check them for cracks at the bottom seam. You can also try swapping the top and bottom wash arms and see if the issue goes away. In my experience, AM14s will leak...
  45. Replies
    6
    Views
    2,371

    time for exploratory surgery....My bet would be...

    time for exploratory surgery....My bet would be either an issue with the shifting yokes inside the transmission, an issue with the clutch gears not sliding up and down on the clutch shaft correctly,...
  46. Replies
    4
    Views
    1,034

    I too agree it may be in fair shape, but guessing...

    I too agree it may be in fair shape, but guessing at what burner it has is an invite to a legal Sh!%storm if something goes wrong. If you doubt me watch a trial lawyer in action...
  47. Replies
    4
    Views
    1,034

    If I were to guess I would say an old us range or...

    If I were to guess I would say an old us range or maybe an old jade.....might even be a montague.....without any I.D. plate it is just a guess, but the knob looks like a us range type knob. Perhaps...
  48. Replies
    14
    Views
    2,279

    Your time was not wasted...I have the file on my...

    Your time was not wasted...I have the file on my 'puter now and Thank You!
  49. Replies
    19
    Views
    4,030

    don't hold your breath...I am still waiting for...

    don't hold your breath...I am still waiting for my mom and pop baked goods......
  50. Replies
    19
    Views
    4,030

    If this unit was putting out 188 degrees...

    If this unit was putting out 188 degrees centigrade, the vacuum breaker in the top left rear corner would be leaking and the booster tank would boil itself dry....water boils @100 degrees centigrade....