  • 03-27-2010, 08:34 AM
    itsiceman

    Weird

    Quote Originally Posted by QTEMP View Post
    Not all CVD units work in Chicago or anywhere that the ambient temperature drops below 0 degrees.
    Just saw this thread Jabs you kill me

    Yes Q I agree they work slower when it gets cold.
    They work to spec in the cold what ever town you happen to be in though
    Sounds like you know how to fix them IMO
    Is it other guys you work with that couldn't and the factory seeing through the BS that has you all peeved
    I think all that mod stuff was to cover for your other guys maybe.
    Dude the only thing you forgot on your fix was electric heaters soldered to the back of the plate

    Also the Hosi recommendation in cold weather climates. You got to be pissed about something else.
    Can you imagine a Hosi Serenity working in a cold climate
  • 03-26-2010, 11:34 PM
    QTEMP
    Quote Originally Posted by Jabarco View Post
    Ice-O-Matic? Capture the market?



    Why? Because they were force to sell Ice-O-Matic to Braveheart Aquisitions Inc because Manitowoc had the monopoly on the ice machine world?
    Yeah, OK. http://www.manitowocice.com/news/icedivestiture.asp
    They were forced to sell Iceomatic and Scotsman due to monopoly laws that the EU mandated if the sale was to go through. Nice move....MTW is around 13 bucks right now. Warburg-Pincus bought Iceomatic.......don't know about the other firm you mentioned. Ideomatic has captured more market share.........wait and see.
  • 03-26-2010, 11:30 PM
    QTEMP
    Not all CVD units work in Chicago or anywhere that the ambient temperature drops below 0 degrees.
  • 03-26-2010, 11:27 PM
    mud
    On One machine I found somebody swapped the wires on the curtain switches. When 1 side dropped it shut the valve for the other side.
  • 03-26-2010, 10:48 PM
    pdrake65
    Quote Originally Posted by QTEMP View Post
    Not all Manitowoc's work in Chicago.........especially when your customer keeps resetting the machine since they don't want to pay you to do it. Define right.....right installation, right refrigerant charge, right PM service, right diagnostics, right brazing job on a Danfoss valve, right Danfoss solenoid coils that short to ground and blow the entire charge on a remote system, right ice thickness probe that doesn't fail and will be rejected on a warranty claim. Wake up.
    Not all Manitowocs work in Chicago?!? What is that supposed to mean?
  • 03-26-2010, 10:34 PM
    QTEMP
    Not all Manitowoc's work in Chicago.........especially when your customer keeps resetting the machine since they don't want to pay you to do it. Define right.....right installation, right refrigerant charge, right PM service, right diagnostics, right brazing job on a Danfoss valve, right Danfoss solenoid coils that short to ground and blow the entire charge on a remote system, right ice thickness probe that doesn't fail and will be rejected on a warranty claim. Wake up.
  • 03-25-2010, 09:23 PM
    refexp
    Manitowocs work fine in the midwest when they are right. -15 this past winter and I didn't get calls so I could nurse it through the harvest cycle. But I don't want to get involved with EGO's. ANyway. I had a similiar problem where the right side dumped the ice but the left side sometimes wouldn't. Come to find out, the contractor before replaced the board but didn't re-use the 26k resistor that was needed for dual operation. Otherwise it was operating singularly. Once rightside would finish, it energize the leftside. Not have enough time to dump the left it would eventually shutdown on safety #2. I ask tech support if they sent a resistor with the new board and they said they didn't but they could sell me one for $20. Anyway, i installed the resistor and it worked fine.
  • 08-13-2009, 01:34 AM
    Jabarco
    Quote Originally Posted by QTEMP View Post
    OK....Then I will talk to your customers. Mark me words, Iceoamtic will capture market share. Watch and see!!!!

    Ice-O-Matic? Capture the market?



    Why? Because they were force to sell Ice-O-Matic to Braveheart Aquisitions Inc because Manitowoc had the monopoly on the ice machine world?
    Yeah, OK. http://www.manitowocice.com/news/icedivestiture.asp
  • 08-12-2009, 09:30 PM
    QTEMP
    Quote Originally Posted by Jabarco View Post
    Talk to the hand.....

    Jabs
    OK....Then I will talk to your customers. Mark me words, Iceoamtic will capture market share. Watch and see!!!!
  • 08-12-2009, 02:56 PM
    Jabarco
    Quote Originally Posted by QTEMP View Post
    Proof that some peolpe still can't see the forrest through the trees. Here's another one to laugh at.......buy some physicasl silver and gold since the dollar in your pocket won't be worth much in the next 2-5 years. That will be real funny!!! Keep drinking the Koolaide!!! Goodluck when your customer doesn't have ice in the bin when it's cold outside, becasue my customers will since I do know what I am talking about.

    Talk to the hand.....

    Jabs
  • 08-12-2009, 07:51 AM
    QTEMP
    Quote Originally Posted by Jabarco View Post
    Ice-O-Matic?.........ROTFLMAO.



    You had me convinced all the way up until the part about the ice-o-matic.
    That's when you lost me.
    Proof that some peolpe still can't see the forrest through the trees. Here's another one to laugh at.......buy some physicasl silver and gold since the dollar in your pocket won't be worth much in the next 2-5 years. That will be real funny!!! Keep drinking the Koolaide!!! Goodluck when your customer doesn't have ice in the bin when it's cold outside, becasue my customers will since I do know what I am talking about.
  • 08-12-2009, 04:44 AM
    Jabarco
    Quote Originally Posted by QTEMP View Post
    If the unit is out of warranty,then go for it. Otherwise, install an Iceomatic remote if you want a great icemaker...
    Ice-O-Matic?.........ROTFLMAO.



    You had me convinced all the way up until the part about the ice-o-matic.
    That's when you lost me.
  • 08-11-2009, 10:29 PM
    QTEMP
    Are these CVD machines or traditional remotes? Either way, here is most likely your problem. First of all, it is IMPERATIVE that the refrigerant charge is correct. Assuming that it is, the solenoid coils and bodies on Manitowoc icemakers, especially around two to three years time become erratic. This will burn the best tech out there period. Chili's switched from Hoshi to Mani years ago, big mistake. The CVD's will not work in Chicago or the midwest of any state north of the Mason Dixon line. Why? Ahhh....I have the answer to that too. There is not enough of sensible or latent heat in the harvest loop to have an efficient harvest. But, there is something you can do to fix it. Buy a 5/8 magna check valve and install it on the discharge line between the compressor and the condenser coil. Raise the fan cycling control to 275 and 240, above the headmaster setting. Weigh the charge in and you will have a BETTER working CVD. I have done this and I am highly trained in Manitowoc systems. Make sure your headmaster is working as well. ANYTHING below the stamped bypass rating means a bad headmaster WARNING: Performing this repair will aggravate the factory and they MIGHT void your warranty. If the unit is out of warranty,then go for it. Otherwise, install an Iceomatic remote if you want a great icemaker...30 second harvest times....or a Hoshizaki...if you set it up right and use an approved filter system.
  • 08-11-2009, 02:42 AM
    Jabarco
    Wildtech,
    I have seen this same problem on several Q1400 with remote condensers. After many service calls I found out what causes this problem. One erratic proximity switch. If one of the proximity switches would have just simply failed, I would not have seen what you're seeing. Unless you can determine which of the two proximity switches is acting erratically, I recommend replacing both of them.

    Jabs
  • 08-06-2009, 07:57 AM
    wildtech
    Quote Originally Posted by crstephens83 View Post
    where is your company based
    midwest il
  • 08-06-2009, 12:00 AM
    crstephens83
    where is your company based
  • 08-05-2009, 11:59 PM
    crstephens83
    just curious i have a bunch of those machines at my chilis too
  • 08-05-2009, 11:57 PM
    wildtech
    Quote Originally Posted by crstephens83 View Post
    have you had any more problems since changing the valves, I highly doubt that it is the board, because they do not have a high failure rate? I have had to change the cool vapor valves due to this same problem. is this machine at a restaurant, if so which one?
    yes chilis no problems I watched it drop about a dozen + batches. The cool gas valves were my suspission but I was wonderin if the H/master would be a cause " the left side was working fine prior to changing valves" I'm wonderin becuase I've heard guys talk about mani's takin them for an ride
  • 08-05-2009, 11:46 PM
    crstephens83
    have you had any more problems since changing the valves, I highly doubt that it is the board, because they do not have a high failure rate? I have had to change the cool vapor valves due to this same problem. is this machine at a restaurant, if so which one?
  • 08-05-2009, 11:41 PM
    wildtech
    Quote Originally Posted by crstephens83 View Post
    ok so i am pretty sure that the cool vapor valves are not wired in parallel, they each come off of a different terminal on the circuit board on that machine, review the schematic. second these machines have been known to act strange on startup after a safety limit shutoff,for the first two cycles or so, and than run properly . Now were your machines off on a safety?
    yes # 2
This thread has more than 20 replies. Click here to review the whole thread.

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  •