  • 07-30-2012, 07:47 PM
    hvacvegas
    Guy I work worth, had an inspector tell him that all bathfans in a commercial building needed to be ran in BI pipe, few years ago.
  • 07-30-2012, 10:24 AM
    palmeri
    Quote Originally Posted by DLZ Dan View Post
    I think its all of NYC (5 Boroughs) because i got knocked down in Staten Island for running PVC pipe instead of copper. A guy who used to work for me used to install commercial dishwashers and had to run everything in blackpipe. I'm not sure about the condensate pump scenario though.
    Luckily, i dont do many installs in NY.
    Man that sucks. Oh well, more hours billable.
  • 07-28-2012, 09:18 AM
    machery
    Gotcha! Lucky here too.
  • 07-28-2012, 08:46 AM
    DLZ Dan
    I think its all of NYC (5 Boroughs) because i got knocked down in Staten Island for running PVC pipe instead of copper. A guy who used to work for me used to install commercial dishwashers and had to run everything in blackpipe. I'm not sure about the condensate pump scenario though.
    Luckily, i dont do many installs in NY.
  • 07-28-2012, 08:13 AM
    machery
    Quote Originally Posted by DLZ Dan View Post
    No plastic pipe...period.
    How long has this code been in effect? Is it the state or city? I was in NY last year and replaced a system for some friends, It was installed in 86 when the entire town house development was built. Every system there had black ABS on the drains and it was ran over into the washing machine standpipe.

    What if the system uses a condensate pump? does the clear vinyl hose fall into the category?

    Just curious! I wonder if this is code in other states? All other states I worked in used plastic.
  • 07-27-2012, 09:16 PM
    DLZ Dan
    Quote Originally Posted by machery View Post
    No PVC for a drain??? Why?? Is black ABS still acceptible?
    No plastic pipe...period.
  • 07-27-2012, 08:03 PM
    randyp1992
    Wow that is just horrible.
  • 07-27-2012, 05:56 PM
    timetable15
    vent is in the wrong place
  • 07-27-2012, 05:46 PM
    palmeri
    Quote Originally Posted by DLZ Dan View Post
    In NY, you cant use PVC for a drain. It has to be copper or black pipe. Sucks huh?
    I've seen this for the interior due to smoke given off during a potential fire but typically if it is outside, you can use pvc. Although I think that is the last thing the inspector would care about on this unit!
  • 07-27-2012, 04:51 PM
    machery
    Quote Originally Posted by DLZ Dan View Post
    In NY, you cant use PVC for a drain. It has to be copper or black pipe. Sucks huh?
    No PVC for a drain??? Why?? Is black ABS still acceptible?
  • 07-27-2012, 01:52 PM
    schr8er
    Quote Originally Posted by DLZ Dan View Post
    In NY, you cant use PVC for a drain. It has to be copper or black pipe. Sucks huh?
    Yeah that sucks. My boss would take my pinky finger as repayment if I did something like that.
  • 07-26-2012, 11:47 PM
    DLZ Dan
    Quote Originally Posted by vzenuh View Post
    all I see is expensive copper. My boss would crap if used copper when 3/4 pvc would work.
    In NY, you cant use PVC for a drain. It has to be copper or black pipe. Sucks huh?
  • 07-26-2012, 09:42 PM
    SgtBone
    At least you can make snow cones while you wait for it to defrost.
  • 07-26-2012, 08:41 PM
    jvillehvac
    Horizontal airhandler installed outside......sucking outdoor air for the return?
    never even heard of hackery that low.
  • 07-26-2012, 07:58 PM
    valentyn
    This is unique a/h unit. NYC building on 37 th floor. Outside on the terrace. Rain, snow ets.
    No air filters, poor return air flow.
    Disaster.


  • 07-26-2012, 07:08 PM
    dandyme
    SOB what a trap
  • 07-26-2012, 07:08 PM
    OldSchoolMech
    Looks like the lineset is frozen up so it leaks when it Thaws??????
  • 07-26-2012, 07:01 PM
    machery
    I see the freezing up too!
  • 07-26-2012, 06:27 PM
    vzenuh
    all I see is expensive copper. My boss would crap if used copper when 3/4 pvc would work.
  • 07-26-2012, 06:20 PM
    tlp7
    they need a cap on the drain but why was it freezing up?
This thread has more than 20 replies. Click here to review the whole thread.