Post a reply to the thread: experimental vacuum setup
You may choose an icon for your message from this list
Please enter the name by which you would like to log-in and be known on this site.
Please enter a password for your user account. Note that passwords are case-sensitive.
Please enter a valid email address for yourself.
Will turn www.example.com into [URL]http://www.example.com[/URL].
I like. CT
Good work! Definitely giving this one a try considering the lengthy time it seems to take pulling a vacuum on some 410a systems.
Originally Posted by ryan1088 This is on my list of things to do when I get back in the office on Wednesday. I already measured mine out so the handle isn't an issue! There you go! ill probley repipe my tee and ill be good to go. works like a champ anyhow
This is on my list of things to do when I get back in the office on Wednesday. I already measured mine out so the handle isn't an issue!
I like it. Every fitting and 'seal' you can eliminate will always help.
Originally Posted by ryan1088 I have the parts to build something just like that sitting in the back of my van!! It suprised me how good it worked, saved a bunch of time, If anybody makes one make sure you raise or lower the tee a little bit, when i made this one i didnt think about it being so close to the handle of the pump. other than that worked great! I usually put it in a vacuum and pick up all my stuff and put everything back together, now my vacuum is done before i finish picking up
Originally Posted by david912 Attachment 315151 Attachment 315161 Attachment 315171 Attachment 315181 took ball valves off hoses so there were to core depressors in any hoses Pulled cores out, took about 10 minutes to pull down to 500, about 15 to pull down to 280, closed ball valves on core tools, killed pump and let sit for 20 minutes. And 570 is what i got. installed cores, pulled vacuum down again, let urr rip. Good enough for me! i meant "no core depressors"
I have the parts to build something just like that sitting in the back of my van!!
I like the tee idea. Sent from my HTC Sensation 4G using Tapatalk 2
experimental vacuum setup Attachment 315151 Attachment 315161 Attachment 315171 Attachment 315181 took ball valves off hoses so there were to core depressors in any hoses Pulled cores out, took about 10 minutes to pull down to 500, about 15 to pull down to 280, closed ball valves on core tools, killed pump and let sit for 20 minutes. And 570 is what i got. installed cores, pulled vacuum down again, let urr rip. Good enough for me!
experimental vacuum setup
Forum Rules