Reply to Thread

Post a reply to the thread: Munchkin Boiler in a commercial building

Your Message

 
 

You may choose an icon for your message from this list

Register Now

Please enter the name by which you would like to log-in and be known on this site.

Please enter a password for your user account. Note that passwords are case-sensitive.

Please enter a valid email address for yourself.

Log-in

Additional Options

  • Will turn www.example.com into [URL]http://www.example.com[/URL].

Topic Review (Newest First)

  • 07-24-2011, 04:04 AM
    LibertyTree
    Damn that looks good
  • 07-19-2011, 06:17 PM
    Josephs LLC
    The electrician on site did the wiring. Not sure why he did it the way he did. If everyone would USE PRIMER than we wouldn't have to use that crappy purple primer! I really hesitated to put this pic up just because of the venting.
  • 07-19-2011, 05:28 PM
    hvacvegas
    Yeah, that purple primer looks like trash, it's a shame they have it as code in some areas.

    I saw you ran some mc out of your switches, and into the switches you ran conduit.

    Is there a reason for the conduit? I'm looking for myself, not questioning your install.

    Every looks extremely nice.
  • 07-19-2011, 12:35 PM
    thes
    no offence, but i heard those boilers don't last too long.
  • 07-19-2011, 12:19 PM
    Josephs LLC
    I swear one of these days I'm goint to redo the venting just because it bothers me so much and take a new pic. It's a big black eye on my artwork, lol.
  • 07-19-2011, 11:52 AM
    hotntired
    That's some nice looking work. Very neat and something to be proud of........except for the venting......
  • 07-15-2011, 01:57 PM
    Josephs LLC

    Munchkin Boiler in a commercial building

    Heres a pic of a small commercial building my company did. Yes I know the venting looks like crap, the ceiling tile guys cut part of our venting out the day before startup. This is a 14,000 sq ft well insulated building with all radiant heat in the concrete. I used all electronic I-valves to control water temp to each zone based on outdoor temp. OTHER THAN THE VENTING, let me know what you think... this job was actually a lot of fun to design and build and the owners love the system! In fact, we are replacing the owners personal heating and AC system since his building is cheaper to heat and cool than his 3000sq ft house.