Originally Posted by dillon2 Ahh theres nothing like a lennox dura-crack heat exchanger! So...was ti cracked? I didn't inspect it, I seen the mess and told him it all had to be replaced regardless. He inquired about price, I told him "I don't want to insult you, but you probably don't want to hire us to do this". That was based on the fact that all that return duct was recently done by a "friend", and as previously stated the house is for sale. Plus he was wiring in a dryer circuit while I was looking at his system in amazement. So I'm thinking this situation holds little potential for me, because he certainly won't appreciate what we provide. Anyhow he pressed further, I gave him a number, he thought it was "absurd". I collected my diagnostic fee and left. Needless to say I haven't heard back and for that I am genuinely happy.
Ya see my Buddy and watch The Home Improvement Channel and who got ourself a Home Depot Credit Card and Did it ourself. So What ya the guys, pretty cool. Next weekend I going to to my own Brain surgery.
Ahh theres nothing like a lennox dura-crack heat exchanger! So...was ti cracked?
One in a million sperm and that one had to make it. The guy that done that job should be burned at the stake with matches till he is well done. People like that really screw the good guys. Each man should be licensed and equipment and parts sold only to a licensed person. Then they could track these jobs. Just venting we seem to see jobs like this at least once a week. Two weeks ago had a landlord call to fix a boiler that a hack had been repairing for 4 yrs said they had a burning smell. Wish i had been allowed to take pictures this guy (Al-qaida look a like) blew up when I came in with a camera. Two 140,000 input boilers both 6" flues, two 30 gallon HWHs 3" flue, vented in a 6" smoke pipe through a combustible ceiling into the back of an open fireplace. The real kicker was he had a 6" duct booster fan in the pipe as a draft inducer. Everything wired in brown zip cord. Didn't want to pay to have it fixed right and told me to leave his property. As I was getting in my truck I swore that I heard smoke detectors going off and the FD was called to the scene. Power Company cut electric off at the pole and locked out the gas meters. Landlord now needs a hand truck to carry the violations to court. It feels good to be an as**ole sometimes. We did not get the repair job but another licensed company did and no one died. Except the George Washingtons in the landlords wallet they sure will bite the dust. LOL.
One in a million sperm and that one had to make it.
even a side job should not look that bad run don't walk away from that
Looks like a big monster ate the system, then puked it back up...
Dave would be proud Bet that Duracrack heat exchanger is busted!!!
Saaweeeeeettt!!!
R Value 0.0 YA see wen I turnz on my heat the air seems all cofused wen it come out . u not gonna chage fo dis cal is ya. ei sez free estamat on yo fone book ad . an o ya i gota 10 dola off kupon .
R Value 0.0
This is a sidejob me and a cousin did when we were in Kansas. r404a
I like the vent adaptor the most.
ROFL!!!! One more type of duct tape and I think they got em all..........
OMG .Did you run away?This is classic.
Ran into this gem yesterday Original call was for blower motor rattles,and has poor airflow. House is for sale and homeowner wanted us to replace the motor to improve air flow. There is a total of 3 supplies, 2 - 6's and the pièce de résistance a 5" split with a tee right off the plenum and then split yet again by another tee to 2 more 5's. And yes indeed that is an aluminum dryer vent 90 off of the draft diverter going into type b vent that is ran backwards all the way to the chimney. The blower motor was completely caked with dirt as well as the coil. I informed him that the last thing he needed was a new blower motor.
Ran into this gem yesterday