  • 03-05-2012, 04:45 PM
    skippedover
    Ah, the old Winkler. Made GREAT boat moorings out our way! That one looks like it's in an old Columbia boiler??? I thought all those old things were gone years ago. Borg Warner, now York, if I recall correctly. Never ran worth a darn on #2, let alone perfume or peanut oil as originally claimed!
  • 03-04-2012, 05:20 PM
    hvactechdan
    do yourself a favor, walk away from that death-trap
  • 03-02-2012, 10:09 PM
    voodoo
    Big time Fail!
  • 03-02-2012, 07:12 PM
    Chuck
    Quote Originally Posted by furnacedoc View Post
    That's looks like one I'd sell
    I think Cody would agree with you!!
  • 03-02-2012, 05:01 PM
    hearthman
    They thought it was a cold air trap so it wouldn't backdraft cold air into the unit/home at standby. Guess they overlooked that little thing about venting and CO....
  • 03-02-2012, 03:31 PM
    Texas-Tech
    Boy I'm glad I don't have to work on that old crap.
  • 03-02-2012, 03:25 PM
    Mustafatel
    big miss
  • 02-28-2012, 06:46 PM
    fridgitator
    A downflue installation? I'm really glad I don't work on residential.
  • 02-26-2012, 12:13 AM
    deux
    I am so so sorry you had to see that. I wrecking ball is in order.
  • 02-25-2012, 03:44 PM
    blitz
    if you touch it it'll break down. just leave it...lol. did it meet the code and the time of installation? if yes, it could be grandfathered in...
  • 02-24-2012, 11:16 PM
    furnacedoc
    That's looks like one I'd sell
  • 02-24-2012, 06:12 PM
    greg r
    OOPs, that work is older than me. It's just that the cellar looked like the old homestead's one.
  • 02-24-2012, 04:29 PM
    VTP99
  • 02-24-2012, 04:22 PM
    zw17
    The barometric damper is the kicker!

    Pure awesome.
  • 02-24-2012, 03:56 PM
    tunnel_rat
    Sweet...hasn't killed anybody yet has it..???
  • 02-24-2012, 10:55 AM
    greg r
    I thought the cellar looked kinda familiar with the rock foundation.

    Then I saw the location, Lancaster, my home town.
  • 02-01-2012, 07:59 AM
    Bald 2
    .....and the "Dip Stick" forgot the dip stick!!
  • 02-01-2012, 07:35 AM
    dna
    It's weird, i tell ya. It would have run like this for a very long time. I don't understand how flue products are supposed to go downhill. Maybe it's a low pressure thing?!??
  • 01-31-2012, 08:45 PM
    jnsrose
    Hey, I know whats wrong, He forgot the drip leg.
  • 01-31-2012, 08:09 PM
    trouble time
    Just a thought....The barometric damper had to be at a level below the top of the boiler?

    OR, too much beer, no installation manual.