  • 10-05-2012, 07:20 AM
    Joehvac25
    I don't think that rule applies to spiro.


    Sent from my iPhone using Tapatalk
  • 10-04-2012, 09:44 PM
    tedkidd
    Quote Originally Posted by hvacvegas View Post
    Looks nice and clean.

    Before you finish though, is it still possible to increase the distance of straight pipe going into your air seperator.

    Those models need about 18" of straight pipe for laminar flow, so the air seperates from the water, and allows the scoop to "scoop" it up.
    Oooo, one of those little things. Nice to know.

    True for Spiro too?
  • 09-07-2012, 10:17 PM
    jtrammel
    Nice work
  • 09-07-2012, 10:08 PM
    Joehvac25
    Quote Originally Posted by jpsmith1cm View Post
    Gotcha.


    Moved to wall of pride
    Thanks


    Sent from my iPhone using Tapatalk
  • 09-07-2012, 10:07 PM
    jpsmith1cm
    Quote Originally Posted by Joehvac25 View Post
    Jp please held I can't send a MSG for some reason but can you move this to walk of fame
    Gotcha.


    Moved to wall of pride
  • 09-07-2012, 09:43 PM
    Joehvac25
    Jp please held I can't send a MSG for some reason but can you move this to walk of fame
  • 09-07-2012, 09:36 PM
    Joehvac25
    Quote Originally Posted by Wheelbaron View Post
    Are you sure your "T" fittings are spaced close enough together? Is that a secondary LWCO at the top of the boiler loop? If so why? Looks clean, get one of the mods to move it to WOP
    The tees have to be a maximum of "12 apart, our inspector still requires a LWCO even though it has one internally. I think I will msg a mod, thought they would have done it by now lol.
  • 09-07-2012, 08:46 PM
    OldSchoolMech
    Clean install
    Post should be in WOP section.
  • 09-07-2012, 07:12 PM
    Wheelbaron
    Are you sure your "T" fittings are spaced close enough together? Is that a secondary LWCO at the top of the boiler loop? If so why? Looks clean, get one of the mods to move it to WOP
  • 09-07-2012, 03:52 PM
    blitz
    if thats WOS for you I wonder how good is your WOF install???
  • 09-06-2012, 07:52 PM
    Joehvac25
    Quote Originally Posted by hvacvegas View Post
    Looks nice and clean.

    Before you finish though, is it still possible to increase the distance of straight pipe going into your air seperator.

    Those models need about 18" of straight pipe for laminar flow, so the air seperates from the water, and allows the scoop to "scoop" it up.
    Lol I know but it's all cast iron rads so in reality it don't even need one, otherwise I would have been more concerned.
  • 09-06-2012, 07:50 PM
    hvacvegas
    Looks nice and clean.

    Before you finish though, is it still possible to increase the distance of straight pipe going into your air seperator.

    Those models need about 18" of straight pipe for laminar flow, so the air seperates from the water, and allows the scoop to "scoop" it up.
  • 09-06-2012, 07:48 PM
    Joehvac25
    I guess if it never gets moved to wall of fame thats my sign to quit lol, thanks guy
  • 09-06-2012, 07:43 PM
    SFhvacguy
    No idea but clean install

  • 09-06-2012, 06:34 PM
    Joehvac25
    **** wrong place lol now how do I change it?
  • 09-06-2012, 06:33 PM
    Joehvac25

    Triangle tube challenger

    Here is the start of my challenger job, first time installing one.

    Before
    Attachment 306361

    After
    Attachment 306371

    With cover
    Attachment 306381