Post a reply to the thread: Picard Bowl lift
You may choose an icon for your message from this list
Please enter the name by which you would like to log-in and be known on this site.
Please enter a password for your user account. Note that passwords are case-sensitive.
Please enter a valid email address for yourself.
Will turn www.example.com into [URL]http://www.example.com[/URL].
Originally Posted by Ovenguy That works a little different then Savage Bros. in that the Picard is using a relay to reverse the direction. Is it possible that the gearbox is causing a binding on tilting back up? I added a diode this way i would not make a short circuit. When i changed the direction of the motor.
That works a little different then Savage Bros. in that the Picard is using a relay to reverse the direction. Is it possible that the gearbox is causing a binding on tilting back up?
Attachment 266921
Yes, I replaced them with a selector switch with a spring return.
How does it tilt? Is it a toggle switch? We work on a lot of savage Bros. bowl lifts and this switch goes out over time.
Limit switch maybe
Picard Bowl lift Anyone had work on this type of equipment. Mod LP-2800BL Ser. 1190980 220-240V charger. 12VDC system. Having problems with the Tilt return. The tilt down is no problem.
Picard Bowl lift
Forum Rules