...Just another long combo day. VS furnace with 4 ton A/C
http://ww2.imagewiz.net/images/hvac/148411_Some_pics_084.jpg
http://ww2.imagewiz.net/images/hvac/148412_Some_pics_086.jpg
http://ww2.imagewiz.net/images/hvac/148413_Some_pics_087.jpg
http://ww2.imagewiz.net/images/hvac/148414_Some_pics_089.jpg
http://ww2.imagewiz.net/images/hvac/148415_Some_pics_090.jpg
mayguy
10-28-2004, 11:36 PM
Good job.
Customer didn't want a media filter when they used to have EAC?
The old Ruud just was tired out? Or customer just wanted a quiet system?
I see you ran a 8" pipe over to another set of duct.. wasn't it tied up before?
2hot2coolme
10-28-2004, 11:56 PM
Thanx, Still waiting to see your project.
No they didn't want another EAC, the old one was filthy :( These are one of those people that Don't have time for that :( Hopefully I can still talk them into PM.
This was a pretty big house, and they were having airflow problems, I was happy to see the VS came through.
The old drop was an 18X8 with 4 tons of cooling.
I put in a 10X24 and couldn't tell what the other installation was on that second run until I tore everything out, then I saw they were drawing the joist space with blockers. So i added the 9" round to it.
Runs really nice.
Jultzya
10-29-2004, 12:36 AM
Nice job.
Questions:
No drain trap and the uncapped vent?
Where's the electrical cut-off?
Still no coil box. :(
Gotta love those old humids! :D
Specky work as per usual 2hot... beautiful duct work... and a well deserved 'wobbly pop' when the job was done...
Sure you don't want to come up to Canada... and embelsish a 'cool' team?
I often prompt my apprentices to check out your work... Baldloonies too.... actually, several of these HVAC Guru's. I also pimp them up to listen to all responses too... sometimes negative comments prompt them to look deeper at the whole picture...
Thanks man. good work.
2hot2coolme
10-29-2004, 08:04 PM
Originally posted by jultzya
Nice job.
Questions:
No drain trap and the uncapped vent?
Where's the electrical cut-off?
Still no coil box. :(
Gotta love those old humids! :D
Thanx,
I don't put traps on upflow systems...don't know why...probably never will :D
There's a switch with duplex outlet, just can't see it from the shots.
I didn't think a cased coil would fit until i tore everything out :(
At least i put an accessible coil panel in for ya when you service this baby :D
2hot2coolme
10-29-2004, 08:17 PM
Originally posted by ricm
Specky work as per usual 2hot... beautiful duct work... and a well deserved 'wobbly pop' when the job was done...
Sure you don't want to come up to Canada... and embelsish a 'cool' team?
I often prompt my apprentices to check out your work... Baldloonies too.... actually, several of these HVAC Guru's. I also pimp them up to listen to all responses too... sometimes negative comments prompt them to look deeper at the whole picture...
Thanks man. good work.
Thanx brutha, "wobbly pops" were in effect...after 9 :D
Canada is wayyy tooo cold for me, heck, I don't care for the weather here when it gets below 30, thanx for the offer though.
I'll try to keep posting my work. I could do this everyday, but it would get pretty boring seeing typical furnace installs.:)
BaldLoonie
10-30-2004, 10:51 AM
Cased coil sure is easy but with the power hum, could be a problem too. We never trap upflow drains either. Often put the Tee in for easy flushing. You may call it nothing fancy but a nice install none the less. Whose bottle of brew left on the WH? :D